    UPW-Q700HXJ Automatic Anionic Surfactant Analyzer
     
    Product Introduction
    The UPW-Q700HXJ Automatic Anionic Surfactant Analyzer is designed to determine anionic surfactants in tap water, surface water, and wastewater. Based on the methylene blue spectrophotometric method, it automates sample preparation, reagent addition, extraction, phase separation, measurement, data processing, and cleaning.
    Traditional manual testing involves labor-intensive pretreatment, considerable reagent consumption, and direct handling of extraction solvents such as chloroform. The UPW-Q700HXJ integrates these procedures into an automated system, reducing routine manual operations and limiting operator contact with extraction reagents.
    With a built-in 7-inch touchscreen, automatic standard preparation, and batch-sampling capability, this analyzer is suitable for environmental monitoring laboratories, water quality testing facilities, and research institutions.

     


    Performance Features
    •  Fully automated analysis: Automates reagent dispensing, extraction, back-extraction, separation, sample introduction, measurement, and cleaning.
    •  Enclosed extraction system: Helps reduce operator exposure to extraction solvents during routine testing.
    •  Standalone touchscreen control: The built-in 7-inch touchscreen and control system eliminate the need for a separate computer during routine operation.
    •  Integrated sample processing: Combines sample loading and pretreatment in one compact system.
    •  Automatic batch testing: Supports continuous analysis of multiple samples with automatic measurement and data storage.
    • Automatic moisture removal: Uses an imported oil-water separation membrane to remove water and impurities from the extract.
    • Precise reagent dispensing: Combines precision syringes with peristaltic pumps to improve dispensing accuracy and processing efficiency.
    • Adjustable extraction ratio: Allows users to adjust the extraction ratio according to testing requirements.
    • Automatic calibration preparation: Automatically prepares standards at different concentrations and generates calibration curves.
    • Automatic result printing: Prints measurement results directly from the instrument.

     


    Working Principle
    The UPW-Q700HXJ uses the methylene blue spectrophotometric method for anionic surfactant determination, following the referenced GB 7494-87 method and GB/T 5750.4-2006 standard.
    The analyzer automatically adds methylene blue reagent and an extraction solvent to the water sample. Anionic surfactants react with methylene blue to form a blue ion pair that can be extracted into the organic phase. After repeated extraction and back-extraction, the analyzer removes residual water, transfers the prepared extract into a spectrophotometer flow cell, and measures absorbance at 652 nm.
    The instrument calculates the anionic surfactant concentration from the calibration curve prepared using standard solutions, with results expressed as LAS-equivalent concentration.

     


    Technical Specifications
    Parameter Specification
    Model UPW-Q700HXJ
    Measurement Item Anionic surfactants
    Applicable Samples Tap water, surface water, wastewater
    Measurement Method Methylene blue spectrophotometric method
    Referenced Standards GB 7494-87; GB/T 5750.4-2006
    Measurement Range 0.10–2.0 mg/L, expressed as LAS standard
    Sample Volume 100 mL
    Measurement Wavelength 652 nm
    Absorbance Range 0.0000–3.0000 A
    Extraction Recovery >95%
    Linear Correlation Coefficient >0.999
    Measurement Time 10–20 minutes
    Standard Preparation Automatic preparation of standards at different concentrations
    Calibration Automatic calibration curve generation
    Liquid Handling Precision syringe and peristaltic pump
    Operation Standalone automatic batch testing
    Display 7-inch touchscreen
    Result Output Automatic printing and data storage
    Power Supply 220 V ±10%, 50 Hz
    Rated Power 200 W
     


    Application Scenarios
    The UPW-Q700HXJ automatic anionic surfactant analyzer is suitable for:
    •  Tap water and drinking-water quality testing
    •  Surface water and river-water monitoring
    •  Municipal and industrial wastewater analysis
    •  Environmental monitoring laboratories
    •  Water treatment plant testing
    •  Industrial pollution monitoring
    •  University and scientific research laboratories
    •  Routine testing of anionic detergent residues in water

     


    UPW-Q700HXJ vs. Manual Methylene Blue Testing
    Comparison Item UPW-Q700HXJ Automatic Analyzer Manual Spectrophotometric Method
    Sample Preparation Automated Manual
    Reagent Addition Automated dispensing Manual dispensing
    Extraction and Separation Automated Manual
    Measurement Automated at 652 nm Spectrophotometer operated manually
    Batch Testing Supports automatic batch analysis Requires repeated manual handling
    Calibration Automatic standard preparation and curve generation Depends on laboratory procedure
    Cleaning Automated cleaning cycle Usually performed manually
    Solvent Exposure Enclosed extraction helps reduce direct contact Greater potential for direct operator contact
    Labor Requirement Reduced routine intervention More hands-on work
    Typical Use Routine and batch water quality analysis Laboratories with manual testing workflows
     


    Frequently Asked Questions
    Q1: What does the UPW-Q700HXJ measure?
    It measures anionic surfactants in tap water, surface water, and wastewater using the methylene blue spectrophotometric method.
    Q2: What is the measurement range?
    The specified range is 0.10–2.0 mg/L, expressed as LAS-equivalent concentration.
    Q3: Why is methylene blue used?
    Methylene blue reacts with anionic surfactants to form a colored ion pair that can be extracted and measured spectrophotometrically.
    Q4: What wavelength does the analyzer use?
    The specified measurement wavelength is 652 nm.
    Q5: How long does one measurement take?
    The specified measurement time is approximately 10–20 minutes. Actual throughput depends on the sample batch and operating conditions.
    Q6: Does the instrument require a separate computer?
    No. Routine operation is controlled through the built-in 7-inch touchscreen. The instrument also supports automatic result printing and data storage.
    Q7: Does the analyzer reduce operator exposure to extraction solvents?
    Yes. Its enclosed automatic extraction system is designed to reduce direct operator contact with extraction solvents. Appropriate laboratory ventilation and chemical safety procedures are still required.
    Q8: Can the analyzer prepare calibration standards automatically?
    Yes. It can automatically prepare standards at different concentrations and generate the corresponding calibration curve.
    Q9: Which standards are listed for this instrument?
    The supplied specifications reference GB 7494-87 and GB/T 5750.4-2006. Laboratories should verify the applicable current standard and method requirements before compliance testing.


  • Frequently Asked Questions
    Q1: What does the UPW-Q700HXJ measure?
    It measures anionic surfactants in tap water, surface water, and wastewater using the methylene blue spectrophotometric method.
    Q2: What is the measurement range?
    The specified range is 0.10–2.0 mg/L, expressed as LAS-equivalent concentration.
    Q3: Why is methylene blue used?
    Methylene blue reacts with anionic surfactants to form a colored ion pair that can be extracted and measured spectrophotometrically.
    Q4: What wavelength does the analyzer use?
    The specified measurement wavelength is 652 nm.
    Q5: How long does one measurement take?
    The specified measurement time is approximately 10–20 minutes. Actual throughput depends on the sample batch and operating conditions.
    Q6: Does the instrument require a separate computer?
    No. Routine operation is controlled through the built-in 7-inch touchscreen. The instrument also supports automatic result printing and data storage.
    Q7: Does the analyzer reduce operator exposure to extraction solvents?
    Yes. Its enclosed automatic extraction system is designed to reduce direct operator contact with extraction solvents. Appropriate laboratory ventilation and chemical safety procedures are still required.
    Q8: Can the analyzer prepare calibration standards automatically?
    Yes. It can automatically prepare standards at different concentrations and generate the corresponding calibration curve.
    Q9: Which standards are listed for this instrument?
    The supplied specifications reference GB 7494-87 and GB/T 5750.4-2006. Laboratories should verify the applicable current standard and method requirements before compliance testing.


     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com