Position: Home > > Environmental monitoring and analysis > Noise and vibration monitoring instruments > Noise monitor > Type 2193 Automatic Environmental Noise Monitor

Type 2193 Automatic Environmental Noise Monitor

Product ID:HZSzsh029

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberType 2193
    Brand NameQDLAOYING
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    Type 2193 Automatic Environmental Noise Monitor
    Introduction:
    This instrument is an all-weather outdoor noise automatic monitoring terminal, consisting of a data acquisition platform and a data transmission platform. Made of steel, it is capable of adapting to complex all-weather environments. With dust-proof and splash-proof design, it boasts comprehensive functions, compact size, high system integration, and durability, ensuring reliable operation in various complex environments.
    Implementation standard
    GB 3096-2008 Environmental Quality Standards for Noise
    GB/T 3241-2010 Electroacoustics - Octave and Fractional Octave Filters - Level 1
    GB/T 3785-2010 Sound Level Meters - Electroacoustic Characteristics and Methods of Measurement - Level 1
    HJ 640-2012 Technical Specifications for Environmental Noise Monitoring - Routine Monitoring of Urban Acoustic Environment
    HJ 906-2017 Technical Specifications for Automatic Monitoring of Acoustic Environmental Quality in Functional Zones
    HJ 907-2017 Technical Requirements for Automatic Environmental Noise Monitoring Systems
    JJG 449-2014 Octave and Fractional Octave Filters
    JJG 778-2019 Noise Statistical Analyzer
    IEC 61672:2013 Electroacoustics - Sound Level Meters
    Features:
    1. Fully automatic noise monitoring possesses total value analysis function, integral measurement function, and statistical analysis function;
    2. Equipped with multiple data communication interfaces and protocols, it facilitates easy integration into data platforms and allows for the customization of special protocols;
    3. Diverse installation methods are available, allowing for choices based on on-site conditions: smart poles, traffic poles, streetlight poles, etc;
    4. It features electronic compatibility, dust-proof and splash-proof design, complete functionality, compact size, high system integration, and durability, enabling reliable operation in various complex environments
    Technical parameters:
    Host technical specifications
    Measurement range: (30~130) dB(A)
    Frequency range: 10Hz~20kHz
    Sampling frequency: 48kHz
    Noise level of this machine: <19dB
    Protection level: IP55; Electromagnetic compatibility Class A
    Operating environment temperature: (-30~70)°C; humidity: (0~100)%RH (non-condensing)
    Main measurement indicators
    Instantaneous sound level: LXYp, Xpeak (the lower limit of XCpeak measurement is the upper limit of measurement minus 70dB),
    Custom sampling time: (0.1~1)S, X: A, C, Z. Y: F, S, 1
    Equivalent sound level: LXeq1s, LXeqT (customized time equivalent sound level, T=1 minute to 60 minutes), LXeqh (hourly equivalent sound level, hourly), LXeqd (daily integrated data), X: A, C, Z
    Statistical sound levels: Leq, L5, L10, L50, L90, L95, Lmax, Lmin, Ld, Ln, Ldn, SD
    Calibration method: automatic point calibration; standard sound source or electrostatic excitation calibration
    Storage: Storage duration for raw data: >8 years (excluding audio recordings); storage duration for audio recordings: >90 days
    Recording mode: Automatic recording when exceeding standards; Active recording; Support for remote playback
    Recording duration: (10~30) seconds adjustable
    Data communication: RS232, RS485 serial port communication, RJ45 Ethernet port communication, 2G/3G/4G GPRS communication
    Communication protocol: HJ212-2017 protocol, HJ660-2013 protocol (customized), customizable special protocol
    Power supply mode: AC (200~250)V, 50Hz, with built-in UPS (uninterruptible power supply) to ensure normal operation of the host for at least 24 hours after a power outage. Solar power supply (optional)
    Protection methods: burglar alarm, earth leakage protection
    Meteorological technical indicators
    Parameter range
    Temperature: (-40~80)℃
    Relative humidity: (0~100)%RH
    Barometric pressure: (10~1100) hPa
    Wind speed: (0~60) m/s
    Wind direction: (0~360)°
    Rainfall: (0~200)mm/h

     
     
  • Type 2193 Automatic Environmental Noise Monitor
    Introduction:
    This instrument is an all-weather outdoor noise automatic monitoring terminal, consisting of a data acquisition platform and a data transmission platform. Made of steel, it is capable of adapting to complex all-weather environments. With dust-proof and splash-proof design, it boasts comprehensive functions, compact size, high system integration, and durability, ensuring reliable operation in various complex environments.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com