TRS1000 Thermostatic Rocking Shaker

Product ID:SHGCzdhy097

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberTRS1000
    Brand NameHZRUICHENG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    TRS1000 Thermostatic Rocking Shaker
    Product Introduction
    The TRS1000 Thermostatic Rocking Shaker is a multifunctional laboratory instrument that combines stepper motor-driven rocking motion with intelligent PID temperature control. It provides controlled heating and gentle sample movement for incubation, catalysis, mixing, and temperature-controlled sample handling.
    Its PID fuzzy control system automatically adjusts the heating rate to achieve accurate temperature regulation and reduce waiting time. The adjustable rocking angle and speed allow users to adapt operating conditions to different sample types and experimental procedures.
    With an aluminum alloy tray, non-slip pads, temperature calibration, and dual software and hardware over-temperature protection, the TRS1000 is designed for reliable laboratory operation.

     

    Performance Features
    1. Integrated Heating and Rocking: Combines thermostatic temperature control and rocking motion in one instrument, simplifying sample incubation and mixing workflows.
    2.  Intelligent PID Temperature Control: PID fuzzy control automatically adjusts heating output to maintain stable temperature conditions and shorten warm-up time.
    3. Adjustable Rocking Motion: Rocking speed ranges from 0 to 60 rpm, with an adjustable rocking angle of 1°–15°.
    4. User-Friendly Interface: Displays operating status and set parameters in real time for convenient monitoring.
    5. Durable Aluminum Alloy Tray: The tray features non-slip pads to secure samples and support loads up to 5 kg.
    6. Stepper Motor Drive: Provides low-noise operation, reduced interference, and maintenance-free performance.
    7.Temperature Calibration: Built-in temperature calibration function helps maintain measurement accuracy.
    8. Dual Over-Temperature Protection: Software and hardware protection systems improve operational reliability.
    9.Programmable Operation: Stores up to five program segments for convenient experimental setup.
    10. Automatic Multi-Point Temperature Measurement: Supports automatic multi-point temperature measurement for monitoring temperature distribution.

     

    Working Principle
    The TRS1000 integrates a thermostatic heating system with a stepper motor-driven rocking platform.
    The heating system uses PID fuzzy control to regulate temperature based on feedback from the temperature measurement system. It automatically adjusts the heating rate to reach the target temperature efficiently and maintain stable operating conditions.
    The stepper motor drives the platform in a controlled rocking motion. Users can adjust the rocking speed and angle according to sample requirements. The combination of temperature control and rocking motion supports uniform sample handling during incubation, mixing, and other temperature-dependent processes.

     

    Technical Parameters
    Parameter Specification
    Temperature Control Range Ambient +5°C to 65°C
    Timer Range 1 min–99 h 59 min or continuous mode
    Temperature Control Accuracy ≤±0.5°C at 37°C
    Temperature Display Resolution 0.1°C
    Temperature Uniformity ≤±0.5°C at 37°C
    Rocking Speed Range 0–60 rpm
    Multi-Point Temperature Measurement Automatic
    Adjustable Rocking Angle Supported
    Rocking Angle Range 1°–15°
    Heating Time ≤25 min (25°C to 65°C)
    Program Segment Storage 5 segments
    Maximum Load 5 kg
    Input Power 265 W
    Power Supply AC 220 V, 50–60 Hz
    Fuse 250 V, 3 A, Φ5 × 20 mm
    Motor Type Stepper motor
    Tray Material Aluminum alloy with non-slip pads
     

    Application Scenarios
    •  Sample Incubation: Maintaining controlled temperatures while gently rocking laboratory samples.
    • Biotechnology: Supporting temperature-controlled biological sample processing.
    •  Catalytic Reactions: Providing controlled heating and mixing during laboratory reactions.
    • Laboratory Mixing: Combining gentle rocking motion with temperature regulation for sample preparation.
    • Research Laboratories: Supporting temperature-dependent experimental procedures.
    •  Sample Holding: Maintaining selected temperature conditions during sample handling and processing.

     

    Comparison: TRS1000 vs. Conventional Laboratory Rocking Shakers
    Comparison Item TRS1000 Thermostatic Rocking Shaker Conventional Rocking Shaker
    Temperature Control Integrated PID temperature control Often requires separate temperature-control equipment
    Rocking Speed 0–60 rpm Depends on model
    Rocking Angle Adjustable from 1° to 15° Depends on model
    Temperature Calibration Built-in calibration function Depends on model
    Heating Control Automatic PID fuzzy control Depends on configuration
    Program Storage 5 program segments Depends on model
    Sample Support Aluminum alloy tray with non-slip pads Depends on tray design
    Over-Temperature Protection Software and hardware protection Depends on model
     

    Frequently Asked Questions
    1. What is the TRS1000 Thermostatic Rocking Shaker used for?
    The TRS1000 is designed for laboratory incubation, catalysis, sample mixing, and other procedures that require controlled heating combined with gentle rocking motion.
    2. What is the temperature control range?
    The temperature range is ambient temperature +5°C to 65°C. Temperature control accuracy is ≤±0.5°C at 37°C.
    3. What is the adjustable rocking speed?
    The rocking speed ranges from 0 to 60 rpm, allowing users to select suitable movement conditions for different samples.
    4. Can the rocking angle be adjusted?
    Yes. The rocking angle is adjustable from 1° to 15° to accommodate different experimental requirements.
    5. How long does it take to heat from 25°C to 65°C?
    The specified heating time is no more than 25 minutes.
    6. What is the maximum sample load?
    The maximum load capacity is 5 kg. The aluminum alloy tray is equipped with non-slip pads to help secure samples during operation.
    7. Does the TRS1000 support programmable operation?
    Yes. It can store up to five program segments for convenient setup of commonly used experimental procedures.
    8. What temperature protection features are included?
    The instrument features dual software and hardware over-temperature protection, together with a built-in temperature calibration function.
    9. What motor does the TRS1000 use?
    It uses a stepper motor designed for low-noise operation, reduced interference, and maintenance-free performance.

     
     

     
  • Frequently Asked Questions
    1. What is the TRS1000 Thermostatic Rocking Shaker used for?
    The TRS1000 is designed for laboratory incubation, catalysis, sample mixing, and other procedures that require controlled heating combined with gentle rocking motion.
    2. What is the temperature control range?
    The temperature range is ambient temperature +5°C to 65°C. Temperature control accuracy is ≤±0.5°C at 37°C.
    3. What is the adjustable rocking speed?
    The rocking speed ranges from 0 to 60 rpm, allowing users to select suitable movement conditions for different samples.
    4. Can the rocking angle be adjusted?
    Yes. The rocking angle is adjustable from 1° to 15° to accommodate different experimental requirements.
    5. How long does it take to heat from 25°C to 65°C?
    The specified heating time is no more than 25 minutes.
    6. What is the maximum sample load?
    The maximum load capacity is 5 kg. The aluminum alloy tray is equipped with non-slip pads to help secure samples during operation.
    7. Does the TRS1000 support programmable operation?
    Yes. It can store up to five program segments for convenient setup of commonly used experimental procedures.
    8. What temperature protection features are included?
    The instrument features dual software and hardware over-temperature protection, together with a built-in temperature calibration function.
    9. What motor does the TRS1000 use?
    It uses a stepper motor designed for low-noise operation, reduced interference, and maintenance-free performance.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com