    Product features:
    1. Nucleic acid gel imaging, protein gel imaging and so on;
    2. High resolution CCD: 5.57 million effective pixel CCDs, with extremely high resolution and sensitivity;
    3.F1.2/8-48mm automatic three variable lens, can add wide angle, auto focus, no manual adjustment;
    4. Integrated module control system, with intelligent guide, distance teaching, remote diagnosis and other functions, can be directly removed for repair and maintenance;
    5. With 10 minutes of light automatic delay closing and opening and closing UV automatic closing function;
    6. All kinds of gel electrophoresis, clone count, micropore plate, bacteriostasis circle, antibiotic titer, object slice and other pictures can be analyzed and calculated.
    7. The utility model has UV observation port and gumming mouth.
    Product use:
    1. It can be used for various UV and blue excited samples imaging, such as: EBV Gold View TMN GeneFinderTM SYBRTM / GreenTLC board, etc.
    2. Can be used for visible light stimulated sample imaging, such as: silver dye glue, coloring glue, colony, bacteriostasis, micropore plate, dot hybridization, film, object slice and so on;
    3. It can be used for the analysis of various experimental results, such as: PCR quantitative analysis, AFLP / RFLP analysis, genetic tree and microsatellite DNA analysis, dot classification screening function, fluorescence analysis, colony analysis, antibacterial antibiotic titer analysis, object and slice analysis, etc.
    Working principle:
    According to the different mobility of the sample on the gel, the unknown sample can be qualitatively analyzed by comparing with the position of the standard sample, and the composition and properties of the unknown sample can be determined. According to the optical density of the unknown sample, the concentration or mass of the unknown sample can be obtained by comparing the optical density of the unknown sample with the strip optical density of the known concentration, and the unknown sample can be quantitatively analyzed.
    Technical parameters:
    Host parameters:
    1.CCD resolution: 5.57 million effective pixel / 1 / 2 / 2 / 4 / pixel combination function;
    2. Lens: F1.2 / 8-48mm automatic three variable lenses (can be added wide angle, automatic focusing function;
    3. The number of bits collected is: 1: 16 bit-0-65536 gray-scale;
    4. Exposure time: 0-600s;
    5. Pixel size: 4.65 × 4.65;
    6. Sensitivity: 20 PG double-stranded DNA;
    7. Filter: UV / IR 590nm, imported filter set, 535 / 605 / 699nm;
    8. White light transmission board: ultraviolet white light conversion board, area 225 × 225mm;
    9. UV transmission station: 302nm, area 210 × 210mm;
    10. White light reflection lamp: led white light reflection;
    11. Equipped with UV observation window;
    12. Gumming mouth: left and right one;
    13. Size: 370W × 400D × 745mm;
    Software parameters:
    14. Software: shooting software and image analysis software;
    14.1 Modularized shooting process, free to edit and save shooting process and shooting mode;
    14.2 Has a plurality of exposure shooting functions, such as automatic exposure, manual shooting, etc.
    14.3 Analytical Software can be used to analyze various kinds of gel electrophoresis, clone count, micropore plate, bacteriostasis, antibiotic titer, object slice map. Image calculation and analysis;
    14.4 All data, images and graphics can be exported to Excel word, pasting board or other files;
    14.5 Is suitable for Windows 98 / 2000 XP / Win7 / Win8 operating system.
     
  • Product features:
    1. Nucleic acid gel imaging, protein gel imaging and so on;
    2. High resolution CCD: 5.57 million effective pixel CCDs, with extremely high resolution and sensitivity;
    3.F1.2/8-48mm automatic three variable lens, can add wide angle, auto focus, no manual adjustment;
    4. Integrated module control system, with intelligent guide, distance teaching, remote diagnosis and other functions, can be directly removed for repair and maintenance;
    5. With 10 minutes of light automatic delay closing and opening and closing UV automatic closing function;
    6. All kinds of gel electrophoresis, clone count, micropore plate, bacteriostasis circle, antibiotic titer, object slice and other pictures can be analyzed and calculated.
    7. The utility model has UV observation port and gumming mouth. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com