| Model: | TDRF-1 | TDRF-2 | TDRF-3 | |
| Number of specimens | nine groups | Five groups | three groups | |
| Cooling method of condenser | air cooling | |||
| Specimen dimensions | 100*100*400, with the same size of temperature measuring components, and a temperature measuring hole reserved in the center test piece | |||
| Freeze-thaw cycle | 2.5 to 4 hours, with a melting time not less than 1/4 of the freeze-thaw cycle | |||
| Freezing time/temperature | 1.5~2.5 hours / -18±2℃ (adjustable) | |||
| Melting time/temperature | 1.0~1.5 hours/5±2℃ | |||
| Temperature sensor control | ||||
| Sensor 1 | Center temperature control: 5 to -18 ± 2℃ | |||
| Sensor 2 Sensor 3 Sensor 4 |
Adjust the cooling/heating power based on the freeze-thaw state and the temperature gradient of the circulating fluid, achieving a stable operation, energy saving, and consumption reduction of the machine Diagonal temperature control: Monitor the temperature variation within the box to ensure it does not exceed 2℃ Secondary protection temperature control: 50℃ to -30℃ |
|||
| Temperature difference between the center and surface of the test piece | Below 28℃ | |||
| Refrigeration compressor | Imported fully enclosed press | Imported fully enclosed press | Imported fully enclosed press | |
| heating power | 8kw | 7kw | 6kw | |
| Maximum operating power | 8.7kw | 7.3kw | 6.7kw | |
| power supply | 380V (three-phase four-wire) | |||
| Studio size (length, width, height) | 1150×800×600 | 600×600×600 | 600*450*600 | |
| Overall dimensions (length, width, height) | 1870×1250×950 | 1700×900×950 | 1650×900×950 | |
| weight | 700kg | 550kg | 350kg | |