Position: Home > > Lab general equipment > Purification equipment > Nitrogen blowing instrument > ST201A Sulfide Acidification Purge System

ST201A Sulfide Acidification Purge System

Product ID:SYCHDC034

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberST201A
    Brand NameJINANSHENGTAI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ST201A Sulfide Acidification Purge System
    Product Introduction
    The ST201A Sulfide Acidification Purge System is a professional water sulfide pretreatment instrument developed according to the requirements of GB/T 16489-1996 Water Quality Determination of Sulfide – Methylene Blue Spectrophotometric Method and HJ/T 60-2000 Water Quality Determination of Sulfide – Iodometric Method.
    The system is specially designed for the pretreatment of sulfide analysis in water samples. It integrates vertical acid addition, nitrogen gas purge, acidification, and absorption processes into one automated platform.
    With intelligent temperature control, independent nitrogen flow adjustment, automatic water replenishment, and tablet remote operation, the ST201A provides a reliable and efficient solution for sulfide pretreatment in surface water, groundwater, domestic wastewater, and industrial wastewater analysis.

     
    Key Features & Advantages
    1. Integrated Sulfide Pretreatment System
    ● Combines acidification, nitrogen purging, and absorption in one instrument.
    ● Designed for standardized sulfide detection procedures.
    ● Supports simultaneous processing of multiple samples.
    2. Multi-Channel Sample Processing
    ● Supports 1–6 sample channels operation.
    ● Each sample unit operates independently.
    ● Improves laboratory testing efficiency and productivity.
    3. Precise Temperature Control
    ● Built-in constant temperature water bath heating system.
    ● Temperature range: 0–99℃ adjustable.
    ● Temperature accuracy within ±1℃.
    ● Ensures stable reaction conditions during sulfide pretreatment.
    4. Independent Nitrogen Flow Control
    ● Equipped with dedicated nitrogen gas inlet.
    ● Each sample channel has independent rotor flow meter control.
    ● Nitrogen flow range: 60–600 ml/min.
    ● Built-in overpressure protection system improves safety.
    5. Corrosion-Resistant Acid Addition System
    ● Vertical acid addition structure connected with reaction bottles.
    ● PTFE adjustment knobs provide excellent acid and alkali corrosion resistance.
    ● Ensures stable and safe reagent operation.
    6. Intelligent Remote Operation
    ● Equipped with external tablet computer control.
    ● Enables convenient remote operation and program management.
    ● Automatic heating, water level monitoring, and alarm functions improve usability.

     
    Working Principle
    The ST201A Sulfide Acidification Purge System uses the principle of acidification–nitrogen purge–absorption pretreatment for sulfide determination.
    During operation, the water sample is acidified under controlled heating conditions. Nitrogen gas is introduced into the reaction bottle to purge volatile hydrogen sulfide (H₂S) generated during acidification.
    The released sulfide gas is transferred through the gas path into an absorption solution, where it is collected for subsequent quantitative analysis using methods such as:
    ● Methylene blue spectrophotometry
    ● Iodometric titration
    The automated temperature control, nitrogen flow regulation, and reaction process management ensure consistent and accurate sulfide measurement results.

     
    Technical Specifications
    Parameter Specification
    Model ST201A
    Product Type Sulfide Acidification Purge System
    Application Water sulfide pretreatment analysis
    Compliance Standards GB/T 16489-1996, HJ/T 60-2000
    Processing Channels 1–6 samples
    Heating Method Constant temperature water bath
    Temperature Range 0–99℃ adjustable
    Temperature Accuracy ≤ ±1℃
    Nitrogen Flow Control Independent control for each channel
    Nitrogen Flow Range 60–600 ml/min
    Nitrogen Interface External nitrogen source connection
    Acid Addition Method Vertical acid addition
    Acid Adjustment Material PTFE corrosion-resistant knob
    Control Method External tablet remote control
    Power Supply AC 220V, 50Hz
    Rated Power 2000W
    Operating Temperature 10–35℃
    Operating Humidity <60%
    Main Unit Dimensions 800 × 430 × 620 mm
     
    Application Areas
    The ST201A Sulfide Acidification Purge System is widely used for sulfide analysis pretreatment in environmental monitoring and scientific research.
    Application Field Typical Samples
    Environmental Monitoring Surface water and groundwater
    Wastewater Treatment Plants Industrial wastewater and sewage
    Scientific Research Institutes Water chemistry research
    Hydrology Departments Natural water quality analysis
    Chemical Industry Sulfide-containing wastewater testing
    Universities & Laboratories Environmental analysis experiments
     
    ST201A vs Traditional Sulfide Pretreatment Methods
    Feature ST201A Sulfide Acidification Purge System Traditional Manual Pretreatment
    Operation Mode Automated integrated process Manual operation
    Sample Capacity 1–6 samples simultaneously Usually single sample
    Temperature Control Automatic PID control Manual heating adjustment
    Nitrogen Flow Independent flow adjustment Manual control
    Acid Addition Vertical controlled addition Manual addition
    Safety Overpressure protection and alarms Higher operational risk
    Operation Efficiency High throughput Lower efficiency
    Data Consistency Excellent repeatability Depends on operator skill
     
    Frequently Asked Questions (FAQ)
    Q1: What is the ST201A Sulfide Acidification Purge System used for?
    It is used for the pretreatment of water samples before sulfide determination, including acidification, nitrogen purge, and absorption processes.
    Q2: Which standards does the instrument comply with?
    The system is designed according to GB/T 16489-1996 and HJ/T 60-2000 sulfide determination methods.
    Q3: How many samples can be processed at the same time?
    The ST201A supports simultaneous processing of 1–6 samples.
    Q4: What is the function of nitrogen purging?
    Nitrogen purging transfers generated hydrogen sulfide gas from the reaction solution into the absorption solution for accurate measurement.
    Q5: Can the nitrogen flow be adjusted independently?
    Yes. Each sample channel has an independent rotor flow meter with a flow range of 60–600 ml/min.
    Q6: Does the system support automatic temperature control?
    Yes. The built-in PID-controlled water bath automatically maintains the required reaction temperature.

     
    Conclusion
    The ST201A Sulfide Acidification Purge System is an advanced water sulfide pretreatment instrument designed for accurate and efficient sulfide analysis. By integrating acidification, nitrogen purge, absorption, automatic temperature control, and intelligent operation, it provides a reliable solution for environmental laboratories, wastewater monitoring, scientific research, and water quality analysis applications.
     

     

  • Frequently Asked Questions (FAQ)
    Q1: What is the ST201A Sulfide Acidification Purge System used for?
    It is used for the pretreatment of water samples before sulfide determination, including acidification, nitrogen purge, and absorption processes.
    Q2: Which standards does the instrument comply with?
    The system is designed according to GB/T 16489-1996 and HJ/T 60-2000 sulfide determination methods.
    Q3: How many samples can be processed at the same time?
    The ST201A supports simultaneous processing of 1–6 samples.
    Q4: What is the function of nitrogen purging?
    Nitrogen purging transfers generated hydrogen sulfide gas from the reaction solution into the absorption solution for accurate measurement.
    Q5: Can the nitrogen flow be adjusted independently?
    Yes. Each sample channel has an independent rotor flow meter with a flow range of 60–600 ml/min.
    Q6: Does the system support automatic temperature control?
    Yes. The built-in PID-controlled water bath automatically maintains the required reaction temperature.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com