Position: Home > > Analytical instruments > Chromatography Equipment > Gas chromatography > SP-3500 Series Gas Chromatograph

SP-3500 Series Gas Chromatograph

Product ID:FSqi031

Price: US$1.00 ~ US$0.00 PDF Format
Supply Ability:50sets/mon
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberSP-3500
    Brand NameBEIFENRUILI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    SP-3500 Series Gas Chromatograph
     
    Product Introduction
    The SP-3500 Series Gas Chromatograph is a new-generation, high-performance gas chromatography instrument developed from 60 years of research experience and advanced international technology.
    The SP-3500 combines an Android-based full touchscreen interface, an innovative miniaturized cold atomic fluorescence detector, an adaptive electronic pressure control system, a next-generation temperature-control system, and a high-sensitivity amplifier circuit.
    Designed for stable and accurate detection of trace substances, the SP-3500 Gas Chromatograph provides reliable analytical solutions for laboratory testing and research applications.

     


    Performance Features
    •  Android Full Touchscreen: Simple and convenient operation through an intuitive Android-based interface.
    •   Miniaturized Cold Atomic Fluorescence Detector: Innovative detector design for sensitive trace-component detection.
    •   Adaptive EPC System: Intelligent, stable, and accurate control of carrier-gas flow and pressure.
    • Advanced Temperature-Control System: Provides fast and accurate temperature control with comprehensive safety protection.
    • High-Sensitivity Amplifier Circuit: Improves the ability to detect low-concentration substances.
    •  Continuous Status Monitoring: Monitors instrument operation and displays fault information to assist user maintenance.
    •  Hydrogen Safety Protection: The EPC system automatically shuts off hydrogen after three consecutive ignition failures.
    •  TCD Filament Protection: Helps protect the thermal conductivity detector filament during operation.
    •   Reliable Operation: High-quality electronic components and intelligent control support stable long-term operation.

     


    Working Principle
    The SP-3500 Gas Chromatograph uses gas chromatography to separate volatile or thermally stable compounds in a sample.
    The carrier gas transports the vaporized sample through a chromatographic column. Different compounds interact differently with the stationary phase and therefore leave the column at different retention times. The detector converts the separated components into electrical signals.
    The adaptive EPC system precisely controls carrier-gas flow and pressure, while the temperature-control system maintains the required column temperature program. The high-sensitivity amplifier circuit enhances the detection of trace components and supports accurate qualitative and quantitative analysis.

     


    Technical Parameters
    Parameter Specification
    Instrument Name Gas Chromatograph
    Model SP-3500 Series
    Inlet Total Flow Setting Range 0–1000 mL/min (H₂); 0–200 mL/min (N₂)
    Maximum Inlet Operating Temperature 400°C
    Carrier Gas Flow Range and Control 0–1000 mL/min (H₂); 0–200 mL/min (N₂)
    Maximum Heating Rate 50°C/min
    Inlet Pressure Setting Range 0–100 psi
    Carrier Gas Pressure Range and Control 0–100 psi
    Oven Temperature Range 5°C above ambient to 450°C
    Operating System Android
    Display and Operation Full color touchscreen
    Main Detector Feature Miniaturized cold atomic fluorescence detector
    Safety Functions Hydrogen shutoff after three ignition failures; TCD filament protection
     


    Applications
    The SP-3500 Series Gas Chromatograph is suitable for:
    •   Laboratory gas chromatography analysis
    •   Trace-component detection
    •   Qualitative and quantitative compound analysis
    •   Analytical research and method development
    •   Chemical and petrochemical analysis
    •   Environmental sample analysis
    •   Pharmaceutical and material research
    •   Routine laboratory quality control

     


    SP-3500 vs. Conventional GC Systems
    Feature SP-3500 Gas Chromatograph Conventional GC System
    Operation Android full touchscreen Conventional control interface
    Gas Control Adaptive EPC system Standard gas-flow control
    Temperature Control Fast, accurate, and safety-protected Standard temperature control
    Trace Detection High-sensitivity amplifier circuit and advanced detector design Depends on detector configuration
    Safety Automatic hydrogen shutoff and TCD filament protection Depends on system configuration
    Status Monitoring Continuous monitoring with fault prompts May require more manual monitoring
    Ease of Use Simple and convenient touchscreen operation Varies by model
    Analytical Stability Intelligent control and stable electronic systems Depends on system configuration
     


    Why Choose the SP-3500?
    The SP-3500 Series Gas Chromatograph integrates advanced gas-flow control, precise temperature programming, sensitive detection, and intelligent safety functions into one high-performance GC analyzer.
    Its Android touchscreen operation simplifies routine testing, while adaptive EPC and advanced temperature control support stable chromatographic performance. With continuous status monitoring and hydrogen protection, the SP-3500 is suitable for laboratories requiring reliable and efficient trace analysis.

     


    FAQ
    1. What is the SP-3500 Gas Chromatograph used for?
    The SP-3500 is used for gas chromatography analysis, trace-component detection, analytical research, and laboratory quality control.
    2. What operating system does the SP-3500 use?
    The instrument uses an Android-based full touchscreen operating system.
    3. What is the maximum inlet operating temperature?
    The maximum inlet operating temperature is 400°C.
    4. What is the oven temperature range?
    The oven temperature range is 5°C above ambient to 450°C.
    5. What is the maximum heating rate?
    The maximum heating rate is 50°C/min.
    6. What carrier gases are specified for the flow-control system?
    The specified carrier gases are hydrogen and nitrogen. The flow range is 0–1000 mL/min for H₂ and 0–200 mL/min for N₂.
    7. What is the pressure control range?
    The inlet and carrier-gas pressure range is 0–100 psi.
    8. How does the SP-3500 improve safety?
    After three consecutive ignition failures, the EPC system automatically shuts off hydrogen. The instrument also includes TCD detector filament protection.
    9. Does the SP-3500 support instrument status monitoring?
    Yes. The instrument can continuously monitor its operating status and provide fault information to assist users with maintenance.
    10. What makes the SP-3500 suitable for trace analysis?
    The instrument combines a miniaturized cold atomic fluorescence detector, a high-sensitivity amplifier circuit, adaptive EPC, and precise temperature control to support the detection of low-concentration substances.


  • FAQ
    1. What is the SP-3500 Gas Chromatograph used for?
    The SP-3500 is used for gas chromatography analysis, trace-component detection, analytical research, and laboratory quality control.
    2. What operating system does the SP-3500 use?
    The instrument uses an Android-based full touchscreen operating system.
    3. What is the maximum inlet operating temperature?
    The maximum inlet operating temperature is 400°C.
    4. What is the oven temperature range?
    The oven temperature range is 5°C above ambient to 450°C.
    5. What is the maximum heating rate?
    The maximum heating rate is 50°C/min.
    6. What carrier gases are specified for the flow-control system?
    The specified carrier gases are hydrogen and nitrogen. The flow range is 0–1000 mL/min for H₂ and 0–200 mL/min for N₂.
    7. What is the pressure control range?
    The inlet and carrier-gas pressure range is 0–100 psi.
    8. How does the SP-3500 improve safety?
    After three consecutive ignition failures, the EPC system automatically shuts off hydrogen. The instrument also includes TCD detector filament protection.
    9. Does the SP-3500 support instrument status monitoring?
    Yes. The instrument can continuously monitor its operating status and provide fault information to assist users with maintenance.
    10. What makes the SP-3500 suitable for trace analysis?
    The instrument combines a miniaturized cold atomic fluorescence detector, a high-sensitivity amplifier circuit, adaptive EPC, and precise temperature control to support the detection of low-concentration substances.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com