SMC 30C Osmometer

Product ID:HZYJsty006

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberSMC 30C
    Brand NameTJTIANHE
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    SMC 30C Osmometer
    Product Introduction
    The SMC 30C Osmometer is a precision freezing point osmometer designed for measuring the osmolality of clinical human body fluids, including blood, urine, tears, and sweat, as well as pharmaceutical formulations. It also meets the testing requirements of the 2015 Chinese Pharmacopoeia for injections, ophthalmic preparations, osmotic diuretics, and related pharmaceutical products.
    Using the freezing point depression method and a high-precision sensor, the SMC 30C provides accurate, repeatable osmolality measurements with a small sample volume and rapid testing. Its dual refrigeration system supports short pre-cooling time and efficient continuous testing.

     

    Key Features
    •  Large touchscreen LCD with an intuitive Chinese-language interface.
    •  Assisted probe lifting for convenient sample operation.
    •  Freezing point depression principle for accurate osmolality measurement.
    •  High-precision sensor provides excellent repeatability.
    •  Dual refrigeration system shortens pre-cooling time and improves testing efficiency.
    •  Small sample volume of only 50–70 μL.
    •  Simultaneously displays osmolality, freezing point, and molar concentration ratio.
    •  Two-point and multi-point linear calibration for improved linearity.
    •  Refrigeration system uses a heat-transfer-liquid-free design, reducing maintenance.
    •  Built-in database containing hundreds of injection drug names from the Chinese Pharmacopoeia.
    •  Microcomputer-controlled automatic data processing and storage.
    •  Multiple printing formats available.

     

    Working Principle
    The SMC 30C uses the freezing point depression method to determine osmolality. A small sample is introduced into the measurement chamber and cooled to initiate crystallization.
    Dissolved particles in the sample lower its freezing point in proportion to the concentration of osmotically active substances. The instrument accurately detects the freezing point and converts the measured freezing-point depression into osmolality, expressed as mOsmol/kg H₂O.
    The microcomputer automatically processes the measurement data and can display the osmolality value, freezing point, and molar concentration ratio while storing or printing the test result.

     

    Technical Parameters
    Parameter Specification
    Model SMC 30C
    Measurement Principle Freezing point depression
    Measurement Range 0–3000 mOsmol/kg H₂O
    Sample Volume 50 μL (50–70 μL)
    Test Time <2 min
    Pre-cooling Time ≤3 min
    Repeatability RSD ≤±1% (300 mOsmol/kg)
    Accuracy ±2 mOsmol/kg (≤400 mOsmol/kg); ±1% (>400 mOsmol/kg)
    Resolution 1 mOsmol/kg
    Linearity <1% deviation from linearity
    Ambient Temperature 10–30°C
    Relative Humidity 5–80% RH
    Power Supply AC 220 V ±10%, 80 W
    Dimensions 220 × 210 × 360 mm
     

    Applications
    The SMC 30C is suitable for:
    •  Clinical laboratory osmolality testing
    •  Blood, urine, tear, and sweat analysis
    •  Injection and infusion solution testing
    •  Ophthalmic preparation testing
    •  Osmotic diuretic testing
    •  Pharmaceutical quality control
    •  Pharmaceutical R&D laboratories
    •  Hospital and medical laboratories
    •  Research involving body-fluid osmolality

     

    SMC 30C vs. Conventional Osmolality Testing
    Feature SMC 30C Osmometer Conventional Osmolality Testing
    Measurement Principle Freezing point depression May use different methods
    Sample Volume 50–70 μL Often larger
    Test Time <2 min Typically longer
    Pre-cooling ≤3 min Often longer
    Measurement Range 0–3000 mOsmol/kg H₂O Depends on instrument
    Refrigeration Dual refrigeration system Conventional refrigeration
    Maintenance No heat-transfer liquid required May require more maintenance
    Data Processing Automatic Manual or semi-automatic
    Pharmaceutical Database Built-in drug database Usually unavailable
     

    FAQ
    1.  What samples can the SMC 30C measure?
    It is designed for clinical body fluids such as blood, urine, tears, and sweat, as well as pharmaceutical preparations including injections and ophthalmic formulations.
    2. What measurement principle does the SMC 30C use?
    It uses the freezing point depression method, where the reduction in freezing point is correlated with the osmolality of the sample.
    3. How much sample is required?
    The standard sample volume is 50 μL, with an applicable range of approximately 50–70 μL.
    4. How fast is the measurement?
    The test time is less than 2 minutes, and the pre-cooling time is ≤3 minutes.
    5. What is the measurement range?
    The SMC 30C covers 0–3000 mOsmol/kg H₂O, with a resolution of 1 mOsmol/kg.
    6. Can the instrument be calibrated?
    Yes. It supports two-point and multi-point linear calibration to maintain measurement linearity and accuracy.
    7. What information is displayed?
    The instrument can simultaneously display the osmolality value, freezing point, and molar concentration ratio.
    8. Is the SMC 30C suitable for pharmaceutical testing?
    Yes. It is designed to support pharmaceutical testing requirements described in the 2015 Chinese Pharmacopoeia, including injections, ophthalmic preparations, and osmotic diuretics.
    9. Does it support data storage and printing?
    Yes. The microcomputer automatically processes and stores measurement data, with multiple printing formats available.

     
     
     
  • FAQ
    1.  What samples can the SMC 30C measure?
    It is designed for clinical body fluids such as blood, urine, tears, and sweat, as well as pharmaceutical preparations including injections and ophthalmic formulations.
    2. What measurement principle does the SMC 30C use?
    It uses the freezing point depression method, where the reduction in freezing point is correlated with the osmolality of the sample.
    3. How much sample is required?
    The standard sample volume is 50 μL, with an applicable range of approximately 50–70 μL.
    4. How fast is the measurement?
    The test time is less than 2 minutes, and the pre-cooling time is ≤3 minutes.
    5. What is the measurement range?
    The SMC 30C covers 0–3000 mOsmol/kg H₂O, with a resolution of 1 mOsmol/kg.
    6. Can the instrument be calibrated?
    Yes. It supports two-point and multi-point linear calibration to maintain measurement linearity and accuracy.
    7. What information is displayed?
    The instrument can simultaneously display the osmolality value, freezing point, and molar concentration ratio.
    8. Is the SMC 30C suitable for pharmaceutical testing?
    Yes. It is designed to support pharmaceutical testing requirements described in the 2015 Chinese Pharmacopoeia, including injections, ophthalmic preparations, and osmotic diuretics.
    9. Does it support data storage and printing?
    Yes. The microcomputer automatically processes and stores measurement data, with multiple printing formats available.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com