Position: Home > > Lab general equipment > Other laboratory equipment > Other auxiliary equipment > SCH-02B Automatic Sample Changer with Automatic Cap Opening Unit

SCH-02B Automatic Sample Changer with Automatic Cap Opening Unit

Product ID:SYQqtfz040

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberSCH-02B
    Brand NameSHYIDIAN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    SCH-02B Automatic Sample Changer with Automatic Cap Opening Unit
    SCH-02B Automatic Sample Changer is an automated laboratory sample handling system designed for titration analyzers and analytical instruments. It integrates automatic sample positioning, stirring, cleaning, liquid waste discharge, and optional automatic cap opening functions, enabling efficient and contamination-reduced sample processing for high-throughput laboratory analysis.
    The system is compatible with ZDJ-5D automatic titrators, desktop L-series titration instruments, and intelligent T-series analytical instruments, providing a complete automated titration workflow.

     

    Product Overview
    The SCH-02B automatic sample changer adopts a dual-tower structure design with a detachable sample tray, supporting a 24-position 100mL sample cup configuration. It improves laboratory efficiency by reducing manual sample replacement and ensuring consistent sample positioning during analysis.
    The optional SCH-02B-1 automatic cap opening unit uses magnetic control technology to automatically open and close sample cup covers. Samples remain sealed before and after measurement, reducing contact with air and minimizing external interference caused by oxidation, evaporation, or environmental contamination.

     

    Key Features
    • 24-Position Automatic Sample Handling
    Supports a 24-position sample tray with 100mL sample cups, enabling continuous automatic sample testing.
    • Dual-Tower Structural Design
    Compact and stable mechanical structure improves positioning accuracy and operational reliability.
    • Automatic Sample Positioning Function
    Provides accurate sample alignment to ensure reliable measurement results.
    • Integrated Cleaning System
    Supports both stirring cleaning and spray cleaning modes to effectively reduce cross-contamination between samples.
    • Flexible Stirring Options
    Upper stirring and lower stirring configurations are available according to different analytical requirements.
    • Automatic Cap Opening and Closing System
    The SCH-02B-1 automatic cap opener uses magnetic force to achieve automatic opening and closing of sample cup lids.
    • Reduced Sample Exposure
    Samples remain sealed before and after measurement, reducing interaction with air and improving analysis stability.
    • Two Cap Handling Modes
    The automatic cap opening unit supports:
    • Cap opening followed by automatic restoration
    • Cap opening followed by cap disposal
    • Automatic Self-Inspection and Status Indication
    Built-in self-check function provides operating status information for easier maintenance and operation.
    • Multiple Pump Options
    PUMP-1 diaphragm pump and PUMP-2 peristaltic pump provide power for spray cleaning, sensor cleaning, and waste liquid discharge.

     

    Working Principle
    The SCH-02B automatic sample changer operates through coordinated mechanical positioning, stirring, cleaning, and liquid handling processes.
    1.The sample tray automatically rotates to move the selected sample cup into the measurement position.
    2.The positioning system accurately aligns the sample with the titration or analytical sensor.
    3.The optional SCH-02B-1 cap opening unit automatically removes or opens the sample cup cover through magnetic control.
    4.The stirring system mixes the sample according to preset requirements.
    5.After measurement, the cleaning system uses diaphragm or peristaltic pumps for sensor cleaning and waste liquid removal.
    6.The sample cup can be automatically sealed again after analysis, reducing contamination and sample degradation.

     

    Technical Specifications
    Parameter Specification
    Model SCH-02B + SCH-02B-1
    Sample Positions 24 positions
    Sample Cup Capacity 100mL sample cups
    Sample Tray Type Detachable rotary tray
    Structure Design Dual-tower structure
    Stirring Function Upper stirring / Lower stirring optional
    Stirring Speed Adjustment 0–45 levels
    Cleaning Functions Stirring cleaning, spray cleaning
    Cap Opening Method Magnetic automatic opening and closing
    Cap Handling Modes Restore after opening / Dispose after opening
    Pump Options PUMP-1 diaphragm pump, PUMP-2 peristaltic pump
    Interface USB, RS232
    Operating Temperature 0–40℃
    Relative Humidity ≤85% RH
    Power Supply AC 80–305V, 47–63Hz
    SCH-02B Dimensions 420 × 580 × 500 mm
    SCH-02B Weight Approx. 16 kg
    SCH-02B-1 Dimensions 310 × 170 × 350 mm
    SCH-02B-1 Weight Approx. 2.5 kg
     

    Applications
    Automatic Titration Analysis
    SCH-02B is widely used as an automatic sample handling module for titration instruments, improving testing efficiency and reducing manual operation errors.
    Chemical Laboratory Testing
    Suitable for laboratories requiring repeated sample analysis with stable sample positioning and cleaning performance.
    Quality Control Laboratories
    Provides automated workflows for industrial quality inspection and routine analytical testing.
    Research Laboratories
    Helps researchers improve experimental repeatability during multi-sample analytical procedures.

     

    Advantages Compared with Manual Sample Processing
    Feature Manual Sample Handling SCH-02B Automatic Sample Changer
    Sample Replacement Manual operation required Fully automatic positioning
    Sample Throughput Limited efficiency 24 samples continuous processing
    Operator Workload High Reduced manual intervention
    Cleaning Process Manual cleaning Automatic cleaning system
    Sample Protection Easily exposed to air Optional automatic sealing
    Measurement Consistency Depends on operator Improved repeatability
     

    Compatible Instruments
    SCH-02B automatic sample changer is designed for seamless integration with:
    • ZDJ-5D Automatic Titrator
    • Desktop L-Series Titration Instruments
    • Intelligent T-Series Analytical Instruments

     

    FAQ
    1. What is SCH-02B automatic sample changer used for?
    SCH-02B is an automatic laboratory sample handling device mainly used with titration instruments to perform automatic sample positioning, stirring, cleaning, and continuous sample analysis.
    2. How many samples can SCH-02B process?
    The system supports a 24-position sample tray with 100mL sample cups, allowing automatic processing of multiple samples.
    3. What is the function of the SCH-02B-1 automatic cap opening unit?
    The SCH-02B-1 automatically opens and closes sample cup covers using magnetic control technology, reducing sample exposure to air and improving measurement reliability.
    4. Can SCH-02B clean sensors automatically?
    Yes. With PUMP-1 diaphragm pump or PUMP-2 peristaltic pump, the system can automatically clean sensors and discharge waste liquid before and after measurement.
    5. Is SCH-02B compatible with existing titration systems?
    Yes. SCH-02B can be directly connected with ZDJ-5D automatic titrators, desktop L-series instruments, and intelligent T-series instruments.
    6. Why choose an automatic sample changer instead of manual operation?
    An automatic sample changer improves testing efficiency, reduces operator workload, minimizes human error, and provides more consistent analytical results for laboratories requiring multiple sample measurements.

     

    SCH-02B Automatic Sample Changer – Reliable Automation Solution for Laboratory Titration and Analytical Workflows
    SCH-02B combines automatic sample handling, intelligent cleaning, optional cap protection, and multi-instrument compatibility, making it an efficient automation accessory for modern analytical laboratories.

     
     
  • FAQ
    1. What is SCH-02B automatic sample changer used for?
    SCH-02B is an automatic laboratory sample handling device mainly used with titration instruments to perform automatic sample positioning, stirring, cleaning, and continuous sample analysis.
    2. How many samples can SCH-02B process?
    The system supports a 24-position sample tray with 100mL sample cups, allowing automatic processing of multiple samples.
    3. What is the function of the SCH-02B-1 automatic cap opening unit?
    The SCH-02B-1 automatically opens and closes sample cup covers using magnetic control technology, reducing sample exposure to air and improving measurement reliability.
    4. Can SCH-02B clean sensors automatically?
    Yes. With PUMP-1 diaphragm pump or PUMP-2 peristaltic pump, the system can automatically clean sensors and discharge waste liquid before and after measurement.
    5. Is SCH-02B compatible with existing titration systems?
    Yes. SCH-02B can be directly connected with ZDJ-5D automatic titrators, desktop L-series instruments, and intelligent T-series instruments.
    6. Why choose an automatic sample changer instead of manual operation?
    An automatic sample changer improves testing efficiency, reduces operator workload, minimizes human error, and provides more consistent analytical results for laboratories requiring multiple sample measurements.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com