RSY-R2 Thermal Shrinkage Tester

Product ID:HZBZqt049

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberRSY-R2
    Brand NameSDPUCHUANG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    RSY-R2 Thermal Shrinkage Tester
    Product Introduction
    The RSY-R2 Thermal Shrinkage Tester is designed to measure the thermal shrinkage performance of heat-shrinkable materials. It is suitable for plastic films and substrates such as PVC film, POF film, PE film, PET film and OPS film, as well as flexible packaging composite films, rigid PVC sheets, solar cell backsheets and other heat-shrinkable materials.
    The thermal shrinkage tester uses an oil-bath heating method with precise PID temperature control, providing stable and reliable temperature conditions for film shrinkage testing. It complies with GB/T 13519 and ASTM D2732 and is suitable for packaging manufacturers, quality inspection laboratories and research institutions.

     

    Performance Features
    •   Microcomputer control with a user-friendly PVC menu interface.
    • High-precision electronic processing for accurate and reliable thermal shrinkage testing.
    •   Oil-bath heating provides uniform and stable heating without a volatile heating medium.
    •   Wide temperature range from room temperature to 200°C.
    • Digital PID temperature control enables rapid heating and minimizes temperature fluctuations.
    •   Automatic timing improves test consistency and measurement accuracy.
    •  Standard specimen film mesh holder ensures stable positioning and uniform heat exposure.
    • Compact and lightweight design for convenient laboratory operation and relocation.

     

    Working Principle
    A prepared film or sheet specimen is placed on the standard specimen holder and immersed in the controlled-temperature oil bath. The tester heats the specimen to the preset temperature and maintains the temperature for the specified test period.
    When exposed to heat, heat-shrinkable materials undergo dimensional changes. The specimen dimensions before and after heating are compared to determine its thermal shrinkage performance. Precise PID temperature control and automatic timing help ensure consistent testing conditions and repeatable results.

     

    Technical Parameters
    Parameter Specification
    Model RSY-R2
    Specimen Size ≤140 × 140 mm
    Temperature Range Room Temperature to 200°C
    Temperature Control Accuracy ±0.3°C
    Heating Medium Oil Bath
    Working Temperature 23°C ± 2°C
    Relative Humidity 50% ± 5% RH
    Power Supply AC 220V, 50Hz
    Dimensions 360(L) × 440(W) × 320(H) mm
    Net Weight 14 kg
    Applicable Standards GB/T 13519, ASTM D2732
     

    Applications
    The RSY-R2 Thermal Shrinkage Tester is widely used for thermal shrinkage testing of:
    •   Plastic heat-shrinkable films
    •   PVC, POF, PE, PET and OPS films
    •   Flexible packaging composite films
    •   Rigid PVC sheets
    •   Solar photovoltaic backsheets
    •   Packaging materials
    •   Other heat-shrinkable polymer materials
    Typical users include packaging manufacturers, quality inspection laboratories, testing institutions, universities and research institutes.

     

    RSY-R2 vs. Conventional Thermal Shrinkage Testing
    Feature RSY-R2 Thermal Shrinkage Tester Conventional Manual Testing
    Temperature Control Digital PID control Manual or less precise
    Temperature Accuracy ±0.3°C Typically less stable
    Heating Method Controlled oil bath Variable heating methods
    Timing Automatic Manual
    Specimen Holder Standard mesh holder Often manually positioned
    Operation Microcomputer menu control More operator-dependent
    Test Consistency High More variable
    Applications Packaging, films, PVC, solar backsheets, R&D Basic shrinkage evaluation
     

    Frequently Asked Questions (FAQ)
    1. What does the RSY-R2 Thermal Shrinkage Tester measure?
    It measures the thermal shrinkage performance and dimensional change of heat-shrinkable materials after controlled heating.
    2. What materials can be tested?
    It can test PVC, POF, PE, PET, OPS and other heat-shrinkable films, flexible packaging composite films, rigid PVC sheets, solar backsheets and similar materials.
    3. What is the maximum specimen size?
    The maximum specimen size is 140 × 140 mm.
    4. What is the temperature range?
    The RSY-R2 operates from room temperature to 200°C, with a temperature control accuracy of ±0.3°C.
    5. What heating method does the tester use?
    The instrument uses a controlled oil-bath heating method to provide stable and uniform heating conditions.
    6. Which standards does it comply with?
    The RSY-R2 is designed according to GB/T 13519 and ASTM D2732.
    7. Is the test time controlled automatically?
    Yes. The instrument features automatic timing, helping improve test repeatability and reduce operator error.
    8. Who can use this thermal shrinkage tester?
    It is suitable for packaging manufacturers, quality control laboratories, testing organizations, universities and research institutions.
     

     
     
     
     
  • Frequently Asked Questions (FAQ)
    1. What does the RSY-R2 Thermal Shrinkage Tester measure?
    It measures the thermal shrinkage performance and dimensional change of heat-shrinkable materials after controlled heating.
    2. What materials can be tested?
    It can test PVC, POF, PE, PET, OPS and other heat-shrinkable films, flexible packaging composite films, rigid PVC sheets, solar backsheets and similar materials.
    3. What is the maximum specimen size?
    The maximum specimen size is 140 × 140 mm.
    4. What is the temperature range?
    The RSY-R2 operates from room temperature to 200°C, with a temperature control accuracy of ±0.3°C.
    5. What heating method does the tester use?
    The instrument uses a controlled oil-bath heating method to provide stable and uniform heating conditions.
    6. Which standards does it comply with?
    The RSY-R2 is designed according to GB/T 13519 and ASTM D2732.
    7. Is the test time controlled automatically?
    Yes. The instrument features automatic timing, helping improve test repeatability and reduce operator error.
    8. Who can use this thermal shrinkage tester?
    It is suitable for packaging manufacturers, quality control laboratories, testing organizations, universities and research institutions.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com