Position: Home > > Analytical instruments > Electrochemical Equipment > Acidity meter/ PH meter > PHSJ-5T Laboratory pH Meter with 0.001 pH Resolution, ORP and Temperature Measurement

PHSJ-5T Laboratory pH Meter with 0.001 pH Resolution, ORP and Temperature Measurement

Product ID:FDph046

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberPHSJ-5T
    Brand NameSHYISIAN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    PHSJ-5T Laboratory pH Meter with 0.001 pH Resolution, ORP and Temperature Measurement
     

    Product Overview
    The PHSJ-5T Laboratory pH Meter is a high-precision benchtop instrument designed for laboratory measurement of pH, ORP (redox potential), mV, and temperature. It features a high-resolution color touchscreen, intelligent electrode and method management, multi-point pH calibration, automatic temperature compensation, and comprehensive GLP/GMP data management.
    With 0.001 pH resolution, USB and RS-232 connectivity, USB flash drive support, and compatibility with an automatic sampler, the PHSJ-5T is suitable for routine laboratory analysis as well as regulated testing environments.

     

    Key Features
    • High-resolution color touchscreen with Chinese and English language support.
    • Selectable pH resolution of 0.001, 0.01, or 0.1 pH and mV resolution of 0.01, 0.1, or 1 mV.
    • Measures pH, ORP, mV, and temperature with automatic temperature compensation.
    • Supports 1–6 point pH calibration and 1-point ORP calibration, with pH electrode diagnostics.
    • Automatically recognizes six buffer solution groups, including GB, DIN, NIST, USA, MERK, and JIS, while also supporting customized standards.
    • Intelligent endpoint recognition with automatic, timed, interval, or manual readings.
    • GLP/GMP-compliant data management with storage, review, statistics, analysis, transfer, printing, and traceability functions.
    • Supports automatic samplers, RS-232 printers, USB PC communication, USB flash drives, and barcode scanners.
    • IP54 protection, power-off protection, automatic shutdown, firmware upgrades, and user permission management.

     

    Working Principle
    The PHSJ-5T determines pH by measuring the electrochemical potential generated by a pH electrode in the sample and converting the signal into a pH value. The instrument can apply automatic temperature compensation to improve measurement consistency under changing sample temperatures.
    For ORP measurements, the meter detects the redox potential of the sample through an ORP electrode. Temperature is measured using a dedicated temperature electrode, allowing simultaneous monitoring and compensation during pH analysis.
    The instrument supports multi-point calibration, buffer recognition, electrode diagnostics, endpoint detection, and measurement alarms to improve measurement reliability and data traceability.

     

    Technical Specifications
    Parameter Specification
    Instrument Class 0.001 grade
    Measurement Parameters Potential, pH, ORP, Temperature
    mV Range -2000.00 to +2000.00 mV
    mV Resolution 0.01 mV
    Electronic Unit Indication Error (mV) ±0.03% or ±0.1 mV
    pH Range -2.000 to 20.000 pH
    pH Resolution 0.001 pH
    Electronic Unit Indication Error (pH) ±0.002 pH
    Temperature Range -10.0 to 135.0°C / 14.0 to 275.0°F
    Temperature Resolution 0.1°C / 0.1°F
    Temperature Indication Error ±0.1°C
    pH Calibration 1–6 points
    ORP Calibration 1 point
    Temperature Compensation Automatic
    Buffer Groups GB, DIN, NIST, USA, MERK, JIS
    Interfaces RS-232, USB
    Protection Rating IP54
    Power Supply AC 100–240 V input, DC 24 V output
    Dimensions 220 × 195 × 68 mm
    Weight 0.95 kg
     

    Applications
    The PHSJ-5T laboratory pH meter is suitable for:
    • Chemical and analytical laboratories
    • Pharmaceutical and biotechnology laboratories
    • Food and beverage testing
    • Water and wastewater analysis
    • Environmental monitoring
    • Scientific research and quality control
    • Universities and research institutions
    • Laboratories requiring GLP/GMP data management and traceability

     

    Applicable Standards
    The PHSJ-5T supports laboratory workflows involving recognized GB, DIN, NIST, USA, MERK, and JIS pH buffer systems. Its GLP/GMP data management functions are designed to support controlled laboratory operations, data traceability, and quality management requirements.

     

    Comparison
    Feature PHSJ-5T Laboratory pH Meter Basic Laboratory pH Meter Advanced pH/ORP Benchtop Meter
    pH Resolution 0.001 pH Typically 0.01 pH Typically 0.001 pH
    pH Measurement Yes Yes Yes
    ORP Measurement Yes Some models Yes
    Temperature Measurement Yes Yes Yes
    Multi-Point Calibration 1–6 points Usually 1–3 points Multi-point
    Automatic Buffer Recognition 6 groups + custom Limited Usually available
    Electrode Diagnostics Yes Limited Usually available
    GLP/GMP Functions Yes Usually limited Model dependent
    Data Storage 1000 sets Limited Usually available
    Automatic Sampler Support Yes Usually no Model dependent
    USB / RS-232 Both Model dependent Usually available
    User Permission Management Yes Limited Model dependent
     

    FAQ
    Q1: What parameters can the PHSJ-5T measure?
    A: It measures pH, ORP, mV/potential, and temperature.
    Q2: What is the highest pH resolution of the PHSJ-5T?
    A: The minimum selectable pH resolution is 0.001 pH, with a pH range of -2.000 to 20.000 pH.
    Q3: How many calibration points does the pH meter support?
    A: It supports 1–6 point pH calibration and 1-point ORP calibration. It also provides pH electrode diagnostic functions.
    Q4: Does the meter support automatic temperature compensation?
    A: Yes. The PHSJ-5T supports automatic temperature compensation and temperature measurement from -10.0 to 135.0°C.
    Q5: Can it recognize standard pH buffer solutions automatically?
    A: Yes. It automatically recognizes six buffer groups: GB, DIN, NIST, USA, MERK, and JIS, and also supports customized standard solutions.
    Q6: Can measurement data be stored and transferred?
    A: Yes. The instrument supports storage of up to 1000 sets of relevant data, as well as data review, analysis, transfer, printing, and USB flash drive operations.
    Q7: Can the PHSJ-5T be integrated with an automatic sampler?
    A: Yes. It supports connection to an automatic sampler for automated measurement and batch testing.
    Q8: What communication interfaces are available?
    A: The meter provides RS-232 and USB interfaces. RS-232 can be connected to a compatible printer, while USB supports PC data communication and USB flash drive operations.

     
     
  • FAQ
    Q1: What parameters can the PHSJ-5T measure?
    A: It measures pH, ORP, mV/potential, and temperature.
    Q2: What is the highest pH resolution of the PHSJ-5T?
    A: The minimum selectable pH resolution is 0.001 pH, with a pH range of -2.000 to 20.000 pH.
    Q3: How many calibration points does the pH meter support?
    A: It supports 1–6 point pH calibration and 1-point ORP calibration. It also provides pH electrode diagnostic functions.
    Q4: Does the meter support automatic temperature compensation?
    A: Yes. The PHSJ-5T supports automatic temperature compensation and temperature measurement from -10.0 to 135.0°C.
    Q5: Can it recognize standard pH buffer solutions automatically?
    A: Yes. It automatically recognizes six buffer groups: GB, DIN, NIST, USA, MERK, and JIS, and also supports customized standard solutions.
    Q6: Can measurement data be stored and transferred?
    A: Yes. The instrument supports storage of up to 1000 sets of relevant data, as well as data review, analysis, transfer, printing, and USB flash drive operations.
    Q7: Can the PHSJ-5T be integrated with an automatic sampler?
    A: Yes. It supports connection to an automatic sampler for automated measurement and batch testing.
    Q8: What communication interfaces are available?
    A: The meter provides RS-232 and USB interfaces. RS-232 can be connected to a compatible printer, while USB supports PC data communication and USB flash drive operations.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com