    MK2000-2E Dual-Channel Dry Block Heater
     
    Product Introduction
    The MK2000-2E Dry Block Heater, also known as a digital dry bath or laboratory metal bath, is a multifunctional laboratory heating system designed for precise and stable sample temperature control.
    Featuring two independently controlled heating modules, the MK2000-2E allows two blocks to be heated and temperature-controlled separately. Its precision-machined metal modules provide efficient heat transfer, rapid heating, and reliable temperature uniformity.
    The system supports a temperature range of ambient +5°C to 105°C, with a maximum setting time of 99 h 59 min. A variety of interchangeable modules are available, and customized modules can be provided for specific sample containers and applications.
    With compact construction, automatic fault detection, temperature deviation calibration, and optional built-in or external sensors, the MK2000-2E laboratory dry bath provides a flexible solution for sample incubation, heating, digestion, reaction preparation, and temperature-controlled laboratory procedures.


    Key Features
    •  Dual-channel temperature control for independent operation of two modules.
    •  Precise temperature control with rapid and safe heating.
    •  Precision-machined metal blocks provide efficient heat transfer.
    •  Temperature range from ambient +5°C to 105°C.
    •  Multiple interchangeable block modules available.
    •  Custom block modules can be designed for specific applications.
    •  Automatic fault detection and alarm function.
    • Transparent PC cover helps reduce environmental interference and experimental variation.
    •  Temperature deviation calibration function.
    •  Rapid heating performance.
    •  Tool/handle supplied for convenient block removal.
    •  Modules can be quickly replaced for easy cleaning and disinfection.
    •  Simple and user-friendly operation.
    •  Optional built-in or external temperature sensor.
    •  Compact design suitable for laboratory bench use.


    Working Principle
    The MK2000-2E dry block heater uses precision-machined metal heating blocks to transfer heat directly to sample tubes, containers, or other compatible vessels.
    The built-in temperature control system continuously monitors the heating temperature and adjusts the heating power according to the programmed setpoint. This closed-loop control helps maintain stable sample temperature during incubation or heating.
    The two heating modules are independently controlled, allowing users to set different temperatures or operating conditions for the two blocks. This dual-channel design improves laboratory efficiency by allowing two different sample groups or procedures to be processed simultaneously.
    Optional internal or external temperature sensors can be used according to application requirements.


    Technical Parameters
    Parameter Specification
    Model MK2000-2E
    Product Type Dual-Channel Dry Block Heater / Digital Dry Bath
    Temperature Range Ambient +5°C to 105°C
    Time Setting Up to 99 h 59 min
    Temperature Stability @ 100°C ≤0.5°C
    Temperature Uniformity ±0.2°C within module @ 37°C
    Heating Time ≤20 min, from 25°C to 100°C
    Display Resolution 0.1°C
    Standard Modules 2
    Module Control Independently controlled
    Temperature Calibration Supported
    Fault Detection Automatic detection and alarm
    Temperature Sensor Built-in or external sensor optional
    Housing / Cover Transparent PC cover
    Net Weight 4.5 kg
    Dimensions 365 × 210 × 150 mm


    Application Scenarios
    The MK2000-2E laboratory dry bath incubator is suitable for temperature-controlled laboratory procedures such as:
    •  Sample incubation
    •  Sample heating
    •  Biochemical experiments
    •  Molecular biology research
    •  Microbiology
    •  Clinical laboratory testing
    •  Pharmaceutical research
    •  Chemical laboratory work
    •  Reagent preparation
    •  Enzyme reactions
    •  Reaction temperature control
    •  Laboratory sample preparation
    •  Research and teaching
    The interchangeable module design allows the dry bath to be adapted to different tube and container formats.


    MK2000-2E vs. Conventional Single-Block Dry Bath
    Feature MK2000-2E Dual-Channel Dry Block Heater Conventional Single-Block Dry Bath
    Heating Channels 2 independent channels Usually 1
    Module Control Independent temperature control Single control
    Temperature Range Ambient +5°C to 105°C Depends on model
    Module Replacement Quick and convenient Depends on design
    Customized Modules Available May be limited
    Fault Detection Automatic fault detection and alarm Basic or unavailable
    Temperature Calibration Supported Depends on model
    Sensor Options Built-in or external Usually fixed
    Laboratory Efficiency Two conditions can run simultaneously One condition at a time
    Cleaning Removable modules simplify cleaning Depends on structure
    The MK2000-2E dual-channel dry bath provides greater flexibility than a conventional single-block heater by independently controlling two heating modules. This allows laboratories to process two different sample groups or temperature conditions simultaneously while maintaining precise and stable temperature control.


    Frequently Asked Questions (FAQ)
    1. What is the MK2000-2E Dry Block Heater used for?
    The MK2000-2E is used for controlled laboratory heating and incubation of samples, reagents, tubes, and compatible laboratory vessels in biochemical, pharmaceutical, microbiological, chemical, and research applications.
    2. Can the two heating modules be controlled independently?
    Yes. The MK2000-2E has two independently controlled heating modules, allowing each module to operate under separate temperature conditions.
    3. What is the temperature range?
    The temperature range is ambient +5°C to 105°C.
    4. How quickly can the dry bath heat from 25°C to 100°C?
    The specified heating time is ≤20 minutes from 25°C to 100°C.
    5. How stable is the temperature at 100°C?
    Temperature stability at 100°C is specified as ≤0.5°C.
    6. What is the temperature uniformity of the module?
    The temperature uniformity within the module is ±0.2°C at 37°C.
    7. Can the modules be replaced?
    Yes. The MK2000-2E uses interchangeable modules that can be conveniently removed and replaced. This also facilitates cleaning and disinfection.
    8. Does the MK2000-2E support temperature calibration?
    Yes. The system provides a temperature deviation calibration function to help maintain accurate temperature control.
    9. Does the dry bath have safety functions?
    Yes. The MK2000-2E provides automatic fault detection and alarm functions, while the transparent PC cover helps reduce environmental interference during experiments.


  • Frequently Asked Questions (FAQ)
    1. What is the MK2000-2E Dry Block Heater used for?
    The MK2000-2E is used for controlled laboratory heating and incubation of samples, reagents, tubes, and compatible laboratory vessels in biochemical, pharmaceutical, microbiological, chemical, and research applications.
    2. Can the two heating modules be controlled independently?
    Yes. The MK2000-2E has two independently controlled heating modules, allowing each module to operate under separate temperature conditions.
    3. What is the temperature range?
    The temperature range is ambient +5°C to 105°C.
    4. How quickly can the dry bath heat from 25°C to 100°C?
    The specified heating time is ≤20 minutes from 25°C to 100°C.
    5. How stable is the temperature at 100°C?
    Temperature stability at 100°C is specified as ≤0.5°C.
    6. What is the temperature uniformity of the module?
    The temperature uniformity within the module is ±0.2°C at 37°C.
    7. Can the modules be replaced?
    Yes. The MK2000-2E uses interchangeable modules that can be conveniently removed and replaced. This also facilitates cleaning and disinfection.
    8. Does the MK2000-2E support temperature calibration?
    Yes. The system provides a temperature deviation calibration function to help maintain accurate temperature control.
    9. Does the dry bath have safety functions?
    Yes. The MK2000-2E provides automatic fault detection and alarm functions, while the transparent PC cover helps reduce environmental interference during experiments.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com