Position: Home > > Environmental monitoring and analysis > Gaseous pollutants > Air detector > MH4030 Full automatic flow calibration instrument

MH4030 Full automatic flow calibration instrument

Product ID:HQWRkq019

Price: Please inquire PDF Format
Supply Ability:80SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberMH4030
    Brand NameYIMA
    Payment TermsT/T, paypal
    Brief introduction
    The instrument adopts the theory of orifice flow, with high precision pressure sensor, can be used in the atmospheric sampler, traffic environment at the same time air particles sampler, flow calibration of portable dust sampler and micro pressure, pressure calibration table.
    The instrument not only can be used for flow rate, pressure measurement, and at the same time open external interface protocols, for built-in sampler of the agreement, just need a data line flow can be realized the function of automatic calibration, such as produced by our companyMH1200Series of sampler.
    Features
    Two way (0.1 ~ 1.0)L/minThe flow measurement.
    2. (all the way10 to 130)L/minThe flow measurement.
    3. (all the way0 ~ 2500)PaMicro pressure measurement.
    4. (all the way- 30.00 ~ + 30.00)kPaGage pressure measurement.
    5. Multi-usage, simple operation.
    6. Two kinds of power-supply modes, ac/dc, built-in high capacity lithium battery.
    7. Small volume, light weight, easy to carry.
    Technical parameter
    The main parameters parameters The resolution of the The accuracy of
    flow The amount (0.1~1.0) L/min 0.1 mL/min Better than + / -1.0%
    (10.0~60.0) L/min 0.1 L/min Better than + / -1.0%
    (60.0~130.0) L/min 0.1 L/min Better than + / -1.0%
    micro pressure (0~2500)Pa 0.1Pa Better than + / -1.0Pa
    table pressure (30.00~+ 30.00)kPa 0.01 kPa Better than + / -0.1kPa
    The environment temperature (- 40~85) 0.1 Better than + / -2.0
    Atmospheric pressure (50~130)kPa 0.01 kPa Better than + / -0.5kPa
    The host weight <2.5Kg
    The power supply mode 220VPlus or minus10%,50HzOr built-in battery
    The machine power consumption <5W
    Overall dimensions (250X122X310 long*width*high)mm
     
  • Brief introduction
    The instrument adopts the theory of orifice flow, with high precision pressure sensor, can be used in the atmospheric sampler, traffic environment at the same time air particles sampler, flow calibration of portable dust sampler and micro pressure, pressure calibration table.
    The instrument not only can be used for flow rate, pressure measurement, and at the same time open external interface protocols, for built-in sampler of the agreement, just need a data line flow can be realized the function of automatic calibration, such as produced by our companyMH1200Series of sampler.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com