    Product Introduction
    The LH-T3NHN Ammonia Nitrogen Rapid Tester is designed for fast determination of ammonia nitrogen (NH₃-N) in water. It complies with the requirements of HJ 535-2009, Water Quality—Determination of Ammonia Nitrogen—Nessler's Reagent Spectrophotometry.
    With a segmented measurement range of 0–160 mg/L, the instrument provides direct concentration readings and supports two colorimetric modes: φ16 mm colorimetric tubes and 10 mm cuvettes. Its 3.5-inch high-definition color display, multiple calibration curves, and 5,000-record storage capacity make it a practical solution for routine water quality testing.

     

    Performance Features
    • Fast ammonia nitrogen measurement: Designed for rapid NH₃-N testing with direct concentration readings and simple operation.
    •  Dual colorimetric modes: Compatible with φ16 mm colorimetric tubes and 10 mm cuvettes for flexible sample measurement.
    •   Multiple calibration options: Provides three measurement modes and 15 selectable calibration curves. Working curves support calibration at commonly used points.
    •  Wide measurement range: Covers 0–160 mg/L in segmented ranges for different water testing requirements.
    •  High-definition color display: Features a 3.5-inch OLED color screen with a clear, intuitive dial-style user interface.
    •  Long-life optical system: Uses a cold light source and narrow-band interference technology, with a stated light source life of up to 100,000 hours.
    •   Large data storage capacity: Stores up to 5,000 measurement records, including test time and measured concentration, for on-device review and comparison.
    •  Compact and lightweight: Weighs only 0.85 kg, making it convenient for laboratory and field testing.

     

    Working Principle
    The LH-T3NHN uses the Nessler reagent spectrophotometric method specified in HJ 535-2009. Under alkaline conditions, ammonia nitrogen reacts with Nessler reagent to produce a colored compound. The instrument measures the absorbance of the resulting solution using its optical system and calculates the ammonia nitrogen concentration based on the selected calibration curve.
    The cold light source and narrow-band interference technology provide a stable optical signal for colorimetric measurement. Users can select the appropriate measurement mode and calibration curve, then read the concentration directly from the display.

     

    Technical Parameters
    Parameter Specification
    Product Name Ammonia Nitrogen Rapid Tester
    Model LH-T3NHN
    Measurement Parameter Ammonia Nitrogen (NH₃-N)
    Applicable Standard HJ 535-2009
    Measurement Method Nessler's reagent spectrophotometry
    Measurement Range 0–160 mg/L (segmented ranges)
    Measurement Modes 3 modes
    Calibration Curves 15 selectable curves
    Colorimetric Modes φ16 mm tube and 10 mm cuvette
    Display 3.5-inch OLED color display
    Indication Error ≤ 8%
    Repeatability ≤ 3%
    Data Storage 5,000 records
    Light Source Cold light source with narrow-band interference technology
    Light Source Life Up to 100,000 hours
    Dimensions 215 × 150 × 110 mm
    Weight 0.85 kg
    Power Supply AC 220 V ±10%, 50 Hz
    Power Consumption 4 W
     

    Application Scenarios
    •   Drinking water quality testing
    •   Surface water monitoring
    •   Industrial wastewater analysis
    •   Municipal wastewater treatment
    •   Environmental monitoring laboratories
    •   Water quality inspection and research
    • Routine ammonia nitrogen testing in industrial and environmental applications

     

    Comparison
    Feature LH-T3NHN Ammonia Nitrogen Rapid Tester Conventional Manual Colorimetric Testing
    Measurement method Nessler reagent spectrophotometry Commonly relies on visual color comparison or separate optical equipment
    Result display Direct concentration reading May require manual comparison or calculation
    Colorimetric containers φ16 mm tube and 10 mm cuvette Depends on the test procedure
    Calibration options 15 selectable curves across 3 modes Depends on the method and equipment
    Data management Stores 5,000 records with time and results Often requires manual recording
    Display 3.5-inch OLED color screen Depends on the equipment
    Portability Compact, 0.85 kg Depends on the equipment
     

    Frequently Asked Questions
    1. What does the LH-T3NHN measure?
    It measures ammonia nitrogen (NH₃-N) concentration in water using the Nessler reagent spectrophotometric method.
    2. Which standard does the instrument follow?
    It is designed to meet HJ 535-2009, Water Quality—Determination of Ammonia Nitrogen—Nessler's Reagent Spectrophotometry.
    3. What is the measurement range?
    The instrument covers 0–160 mg/L using segmented measurement ranges.
    4. Which colorimetric containers are supported?
    It supports φ16 mm colorimetric tubes and 10 mm cuvettes, allowing users to select the appropriate measurement format.
    5. How many calibration curves are available?
    The instrument offers three measurement modes and 15 selectable calibration curves. Working curves also support calibration at commonly used points.
    6. How accurate and repeatable is the measurement?
    The specified indication error is ≤ 8%, and the repeatability is ≤ 3%.
    7. How many test records can the instrument store?
    It can store up to 5,000 records, including measurement time and concentration values, which can be reviewed and compared directly on the instrument.
    8. What type of display and light source does it use?
    It features a 3.5-inch OLED color display and a cold light source with narrow-band interference technology. The stated light source life is up to 100,000 hours.
    9. Is the LH-T3NHN suitable for field testing?
    Its compact dimensions of 215 × 150 × 110 mm and lightweight design of 0.85 kg make it convenient for both laboratory and field applications. It requires an AC 220 V power supply.

     
     

     
  • Frequently Asked Questions
    1. What does the LH-T3NHN measure?
    It measures ammonia nitrogen (NH₃-N) concentration in water using the Nessler reagent spectrophotometric method.
    2. Which standard does the instrument follow?
    It is designed to meet HJ 535-2009, Water Quality—Determination of Ammonia Nitrogen—Nessler's Reagent Spectrophotometry.
    3. What is the measurement range?
    The instrument covers 0–160 mg/L using segmented measurement ranges.
    4. Which colorimetric containers are supported?
    It supports φ16 mm colorimetric tubes and 10 mm cuvettes, allowing users to select the appropriate measurement format.
    5. How many calibration curves are available?
    The instrument offers three measurement modes and 15 selectable calibration curves. Working curves also support calibration at commonly used points.
    6. How accurate and repeatable is the measurement?
    The specified indication error is ≤ 8%, and the repeatability is ≤ 3%.
    7. How many test records can the instrument store?
    It can store up to 5,000 records, including measurement time and concentration values, which can be reviewed and compared directly on the instrument.
    8. What type of display and light source does it use?
    It features a 3.5-inch OLED color display and a cold light source with narrow-band interference technology. The stated light source life is up to 100,000 hours.
    9. Is the LH-T3NHN suitable for field testing?
    Its compact dimensions of 215 × 150 × 110 mm and lightweight design of 0.85 kg make it convenient for both laboratory and field applications. It requires an AC 220 V power supply.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com