Position: Home > > Lab general equipment > Heating / drying equipment > Fast drying apparatus > KFDO-11 Automatic Karl Fischer Drying Oven

KFDO-11 Automatic Karl Fischer Drying Oven

Product ID:SYJRGZksgz010

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberKFDO-11
    Brand NameSHBENANG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    KFDO-11 Automatic Karl Fischer Drying Oven
    Product Introduction
    The KFDO-11 Automatic Karl Fischer Drying Oven (Karl Fischer Sample Heating Oven) is a professional sample preparation device designed for Karl Fischer moisture analysis. It is mainly used for moisture determination of insoluble solid samples, granular materials, sheet materials, and samples that react with Karl Fischer reagents.
    The KFDO-11 adopts a circularly distributed constant-temperature heating station design, which minimizes temperature differences between sample positions and improves measurement stability and repeatability.
    The system works together with a Karl Fischer moisture analyzer and gas supply system. By heating samples and transferring released moisture through a controlled carrier gas path into the Karl Fischer titration cell, it enables accurate moisture measurement without direct contact between difficult samples and Karl Fischer reagents.
    The KFDO-11 Karl Fischer Drying Oven is widely used in lithium battery materials, plastic particles, chemical materials, and scientific research laboratories, and complies with the moisture testing requirements of GB/T24533-2009 Lithium-ion Battery Graphite Anode Materials.

     

    Performance Features
    •   Uniform circular heating design
    Sample heating positions are evenly distributed to minimize temperature gradients and improve analysis reliability.
    •   Wide temperature control range
    Sample heating temperature can be accurately controlled from room temperature to 300℃.
    •   Independent pipeline temperature control
    Heated transfer lines prevent moisture condensation during sample transportation.
    •   Anti-cross contamination design
    Sampling pipeline includes reverse blowing function to prevent sample contamination.
    •   Digital temperature control system
    Microcomputer control with digital temperature display ensures accurate operation.
    •   Flexible instrument compatibility
    Replaceable injection interfaces allow connection with different domestic and international Karl Fischer moisture analyzers.
    •   Multi-sample heating capability
    Supports simultaneous heating of up to four samples.
    •   Suitable for difficult samples
    Ideal for samples that cannot directly contact Karl Fischer reagents.

     

    Working Principle
    The KFDO-11 Automatic Karl Fischer Drying Oven uses the principle of thermal moisture release combined with Karl Fischer titration analysis.
    The working process includes:
    1.  The solid sample is placed into the heating chamber.
    2.  The sample is heated under controlled temperature conditions.
    3.  Moisture released from the sample is carried by dry gas through the heated pipeline.
    4.  The moisture vapor enters the Karl Fischer moisture analyzer.
    5.  The Karl Fischer reagent reacts with the extracted water, and the analyzer calculates the moisture content.
    This indirect measurement method avoids chemical interference between the sample and Karl Fischer reagent, making it suitable for reactive, insoluble, or difficult-to-dissolve materials.

     

    Technical Parameters
    Parameter Specification
    Product Model KFDO-11
    Product Type Automatic Karl Fischer Drying Oven / Sample Heating Furnace
    Application Karl Fischer moisture analysis sample preparation
    Sample Heating Temperature Range Room Temperature - 300℃
    Heating Temperature Resolution 0.1℃
    Pipeline Temperature Range Room Temperature - 150℃
    Pipeline Temperature Resolution 0.1℃
    Flow Calibration Range 0-300mL/min Continuously Adjustable
    Sample Capacity Up to 4 samples simultaneously
    Temperature Control Microcomputer digital control
    Injection Interface Replaceable connection interface
    Required Equipment Karl Fischer Moisture Analyzer + Gas Supply
     

    Applications
    The KFDO-11 Karl Fischer Drying Oven is widely used in:
    Lithium Battery Industry
    •   Lithium cobalt oxide moisture testing
    •   Lithium iron phosphate moisture analysis
    •   Lithium manganese oxide moisture measurement
    •   Graphite anode material moisture testing
    Plastic and Polymer Industry
    •   Plastic particle moisture determination
    •   Polymer raw material quality control
    •   Moisture content analysis before processing
    Chemical Materials
    •   Moisture testing of reactive chemicals
    •   Solid powder material analysis
    •   Inorganic material moisture measurement
    Research Laboratories
    •   Material science experiments
    •   Battery research and development
    •   Quality inspection laboratories

     

    KFDO-11 Karl Fischer Drying Oven vs Direct Karl Fischer Measurement
    Feature KFDO-11 Karl Fischer Drying Oven Direct Karl Fischer Testing
    Sample Type Solid, insoluble, reactive samples Mainly liquid or soluble samples
    Measurement Method Heating moisture release + KF analysis Direct chemical reaction
    Sample Compatibility Excellent for difficult materials Limited by reagent compatibility
    Lithium Battery Materials Highly suitable Often unsuitable
    Chemical Interference Minimized Possible reaction interference
    Cross Contamination Control Reverse blowing function Depends on operation
    Temperature Control Precise heating system Not applicable
     

    Frequently Asked Questions (FAQ)
    1. What is the KFDO-11 Karl Fischer Drying Oven used for?
    The KFDO-11 is used for moisture determination of solid, insoluble, granular, and chemically reactive samples with Karl Fischer moisture analyzers.
    2. Why is a Karl Fischer drying oven needed for lithium battery materials?
    Many lithium salts and battery materials may react with Karl Fischer reagents directly. The drying oven extracts moisture through heating, avoiding chemical interference and improving accuracy.
    3. What samples can be tested with KFDO-11?
    It is suitable for lithium battery materials, plastic particles, powders, solid samples, and materials that are difficult to dissolve or react with Karl Fischer reagents.
    4. How many samples can KFDO-11 heat at the same time?
    The system can simultaneously heat up to four samples.
    5. What is the maximum sample heating temperature?
    The sample heating temperature range is from room temperature to 300℃.
    6. Why does the transfer pipeline need temperature control?
    The heated pipeline prevents moisture condensation during sample transfer, ensuring accurate moisture measurement.
    7. Can KFDO-11 connect with different Karl Fischer moisture analyzers?
    Yes. The injection interface can be replaced to support connection with different brands and models of Karl Fischer analyzers.
    8. Does KFDO-11 comply with lithium battery moisture testing standards?
    Yes. The system meets the requirements of GB/T24533-2009 Lithium-ion Battery Graphite Anode Materials moisture testing methods.

     

    Product Summary
    The KFDO-11 Automatic Karl Fischer Drying Oven is a high-performance Karl Fischer moisture sample heating system designed for accurate water content measurement of difficult solid materials. With uniform heating, controlled gas transfer, anti-contamination design, and compatibility with various Karl Fischer analyzers, it provides an ideal moisture testing solution for lithium battery materials, plastics, chemicals, and advanced material research applications.

     

     
  • Frequently Asked Questions (FAQ)
    1. What is the KFDO-11 Karl Fischer Drying Oven used for?
    The KFDO-11 is used for moisture determination of solid, insoluble, granular, and chemically reactive samples with Karl Fischer moisture analyzers.
    2. Why is a Karl Fischer drying oven needed for lithium battery materials?
    Many lithium salts and battery materials may react with Karl Fischer reagents directly. The drying oven extracts moisture through heating, avoiding chemical interference and improving accuracy.
    3. What samples can be tested with KFDO-11?
    It is suitable for lithium battery materials, plastic particles, powders, solid samples, and materials that are difficult to dissolve or react with Karl Fischer reagents.
    4. How many samples can KFDO-11 heat at the same time?
    The system can simultaneously heat up to four samples.
    5. What is the maximum sample heating temperature?
    The sample heating temperature range is from room temperature to 300℃.
    6. Why does the transfer pipeline need temperature control?
    The heated pipeline prevents moisture condensation during sample transfer, ensuring accurate moisture measurement.
    7. Can KFDO-11 connect with different Karl Fischer moisture analyzers?
    Yes. The injection interface can be replaced to support connection with different brands and models of Karl Fischer analyzers.
    8. Does KFDO-11 comply with lithium battery moisture testing standards?
    Yes. The system meets the requirements of GB/T24533-2009 Lithium-ion Battery Graphite Anode Materials moisture testing methods.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com