JY-CX1B Sequencing Electrophoresis Tank

Product ID:SHFZdy037

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberJY-CX1B
    Brand NameBJJUNYIDONGFANG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    JY-CX1B Sequencing Electrophoresis Tank
     
    Product Introduction
    The JY-CX1B Sequencing Electrophoresis Tank is a professional DNA sequencing electrophoresis apparatus designed for high-resolution nucleic acid separation and molecular biology analysis.
    It is suitable for AFLP analysis, differential display, microsatellite analysis (SSR), SSCP research, heteroduplex nucleic acid analysis, DNA footprinting, RNase protection assays, S1 nuclease mapping and primer extension analysis.
    The JY-CX1B features a specially treated ultra-flat elastic aluminum heat-dissipation plate that closely contacts the gel glass plate. This design provides uniform temperature distribution across the glass plate and helps minimize band distortion caused by uneven heating.
    With a compact buffer system, removable electrode holder, convenient gel loading comb and automatic power cutoff when the cover is opened, the JY-CX1B provides efficient, stable and safe sequencing gel electrophoresis for research and laboratory applications.

     


    Key Features
    •  Wide molecular biology applications: Suitable for AFLP, SSR, SSCP, DNA footprinting and other nucleic acid analysis techniques.
    •  Simple operation: Only four fastening knobs are required for assembly and operation.
    • Reduced buffer consumption: Uses approximately 50% less electrophoresis buffer than conventional water-cooled electrophoresis tanks.
    •  Efficient heat dissipation: Ultra-flat elastic aluminum heat-dissipation plate provides close contact with the gel glass plate.
    •  Uniform temperature distribution: Heat is distributed evenly across the glass plate, helping minimize electrophoretic band distortion.
    •  Full gel-area heat dissipation: The specially treated aluminum plate utilizes the entire plate surface for heat dissipation.
    • Removable electrode holder: Simplifies electrode maintenance and replacement while improving operating safety.
    •  Dual buffer reservoir design: The upper buffer tank is equipped with a drain tube, while the lower buffer tank can be easily removed for buffer disposal.
    •  Safety lid design: A dedicated safety button makes the upper cover easy to open.
    •  Automatic power cutoff: Power to the electrophoresis field is automatically disconnected when the lid is opened.
    •  High-quality shark-tooth comb: The red shark-tooth comb makes sample loading easier to observe and helps prevent sample cross-contamination.
    •  Single-gel configuration: Supports one gel with a thickness of 0.4 mm.
    • High sample capacity: Supports 33- and 40-well shark-tooth comb configurations.

     


    Working Principle
    The JY-CX1B sequencing electrophoresis tank uses an electric field to separate charged DNA or other nucleic acid molecules through a thin polyacrylamide gel.
    A gel is prepared between glass plates and installed in the electrophoresis chamber. Samples are loaded into the gel wells using the shark-tooth comb. When an electrical field is applied, negatively charged nucleic acid molecules migrate toward the positive electrode.
    Because nucleic acid fragments with different molecular sizes migrate through the gel matrix at different rates, they are separated into distinct bands. The resulting band pattern can be analyzed for applications such as DNA sequencing, AFLP, SSR, SSCP, DNA footprinting and primer extension analysis.
    During electrophoresis, the aluminum heat-dissipation plate maintains more uniform thermal conditions across the gel. Uniform heat distribution helps reduce temperature-related band distortion and improves separation consistency.

     


    Technical Specifications
    Parameter Specification
    Model JY-CX1B
    Application Sequencing gel electrophoresis and nucleic acid analysis
    Glass Plate Area (W × L) 200 × 450 mm
    Gel Area (W × L) 180 × 420 mm
    Gel Thickness 0.4 mm
    Number of Gels 1
    Sample Capacity 33 or 40 wells, 0.4 mm gel thickness
    Comb Type Shark-tooth comb
    Buffer Capacity Approx. 500 mL
    Dimensions (L × W × H) 310 × 230 × 500 mm
    Net Weight 11.0 kg
    Heat Dissipation Ultra-flat elastic aluminum heat-dissipation plate
    Electrode Holder Removable
    Safety Function Automatic power cutoff when lid is opened
     


    Applications
    The JY-CX1B sequencing electrophoresis tank is suitable for:
    •  AFLP (Amplified Fragment Length Polymorphism) analysis
    •  Differential display analysis
    •  Microsatellite analysis (SSR)
    •  SSCP (Single-Strand Conformation Polymorphism) research
    •  Heteroduplex nucleic acid analysis
    •  DNA footprinting
    •  RNase protection assays
    •  S1 nuclease mapping
    •  Primer extension analysis
    •  DNA sequencing and sequencing gel electrophoresis
    •  Molecular biology research
    •  Nucleic acid separation
    •  Genetic analysis
    •  University and research laboratories

     


    JY-CX1B vs. Conventional Sequencing Electrophoresis Tank
    Feature JY-CX1B Conventional Water-Cooled Electrophoresis Tank
    Main Application DNA sequencing and nucleic acid analysis Electrophoresis applications
    Buffer Consumption Approx. 500 mL Typically higher
    Buffer Saving About 50% vs. water-cooled design —
    Heat Dissipation Ultra-flat elastic aluminum plate Water cooling or conventional cooling
    Temperature Uniformity High uniformity across glass plate Depends on cooling system
    Band Distortion Control Designed to minimize thermal distortion May be affected by temperature gradients
    Electrode Holder Removable May be fixed
    Buffer Reservoir Upper drain + removable lower tank Conventional reservoir
    Safety Power Cutoff Yes Depends on design
    Sample Loading 33 / 40 shark-tooth wells Depends on configuration
    Operation Four fastening knobs Varies
     


    Heat Dissipation and Band Quality
    A key design feature of the JY-CX1B is its special ultra-flat elastic aluminum heat-dissipation plate.
    The plate closely contacts the gel glass plate, allowing heat generated during electrophoresis to be distributed across the entire plate surface. More uniform temperature distribution helps reduce localized overheating and minimizes the possibility of electrophoretic band distortion, which is particularly important for high-resolution sequencing and nucleic acid analysis.

     


    Safety and Convenient Operation
    The JY-CX1B incorporates several safety-oriented features for laboratory operation.
    A dedicated safety lid button facilitates opening the upper cover, while the automatic power-cutoff function disconnects the electrophoresis field when the lid is opened.
    The removable electrode holder allows electrodes to be inspected, maintained or replaced more conveniently. The upper buffer reservoir has a dedicated drain tube, and the lower buffer reservoir can be removed directly for convenient buffer disposal.

     


    FAQ
    1. What is the JY-CX1B used for?
    The JY-CX1B is a sequencing electrophoresis tank designed for DNA and nucleic acid analysis, including AFLP, SSR, SSCP, DNA footprinting and primer extension analysis.
    2. What electrophoresis applications does it support?
    It supports AFLP analysis, differential display, microsatellite analysis (SSR), SSCP research, heteroduplex nucleic acid analysis, DNA footprinting, RNase protection assays, S1 nuclease mapping and primer extension analysis.
    3. How much buffer does the JY-CX1B require?
    The buffer capacity is approximately 500 mL. Compared with conventional water-cooled electrophoresis tanks, it can save approximately 50% of electrophoresis buffer.
    4. What is the gel size?
    The gel area is 180 × 420 mm, with a gel thickness of 0.4 mm.
    5. How many samples can the sequencing electrophoresis tank accommodate?
    The JY-CX1B supports 33- or 40-well shark-tooth comb configurations for 0.4 mm thick gels.
    6. How does the JY-CX1B control heat during electrophoresis?
    It uses a specially treated ultra-flat elastic aluminum heat-dissipation plate that closely contacts the gel glass plate and provides uniform heat dissipation.
    7. Can the electrode holder be removed?
    Yes. The electrode holder is removable, making electrode maintenance and replacement more convenient and safer.
    8. Does the JY-CX1B have a safety power cutoff?
    Yes. When the upper cover is opened, the electrophoresis field is automatically disconnected to improve operator safety.
    9. What is the buffer reservoir design?
    The upper buffer reservoir has a drain tube, while the lower buffer reservoir can be conveniently removed for pouring out the buffer.
    10. Is the JY-CX1B suitable for molecular biology laboratories?
    Yes. Its high-resolution sequencing gel configuration and compatibility with AFLP, SSR, SSCP, DNA footprinting and other molecular biology techniques make it suitable for research laboratories, university laboratories and genetic analysis applications.

  • FAQ
    1. What is the JY-CX1B used for?
    The JY-CX1B is a sequencing electrophoresis tank designed for DNA and nucleic acid analysis, including AFLP, SSR, SSCP, DNA footprinting and primer extension analysis.
    2. What electrophoresis applications does it support?
    It supports AFLP analysis, differential display, microsatellite analysis (SSR), SSCP research, heteroduplex nucleic acid analysis, DNA footprinting, RNase protection assays, S1 nuclease mapping and primer extension analysis.
    3. How much buffer does the JY-CX1B require?
    The buffer capacity is approximately 500 mL. Compared with conventional water-cooled electrophoresis tanks, it can save approximately 50% of electrophoresis buffer.
    4. What is the gel size?
    The gel area is 180 × 420 mm, with a gel thickness of 0.4 mm.
    5. How many samples can the sequencing electrophoresis tank accommodate?
    The JY-CX1B supports 33- or 40-well shark-tooth comb configurations for 0.4 mm thick gels.
    6. How does the JY-CX1B control heat during electrophoresis?
    It uses a specially treated ultra-flat elastic aluminum heat-dissipation plate that closely contacts the gel glass plate and provides uniform heat dissipation.
    7. Can the electrode holder be removed?
    Yes. The electrode holder is removable, making electrode maintenance and replacement more convenient and safer.
    8. Does the JY-CX1B have a safety power cutoff?
    Yes. When the upper cover is opened, the electrophoresis field is automatically disconnected to improve operator safety.
    9. What is the buffer reservoir design?
    The upper buffer reservoir has a drain tube, while the lower buffer reservoir can be conveniently removed for pouring out the buffer.
    10. Is the JY-CX1B suitable for molecular biology laboratories?
    Yes. Its high-resolution sequencing gel configuration and compatibility with AFLP, SSR, SSCP, DNA footprinting and other molecular biology techniques make it suitable for research laboratories, university laboratories and genetic analysis applications.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com