    Product Overview
    The JQ-8 Channel Automatic Gas Sampler is a high-efficiency multi-channel automated gas injection system designed for batch gas sample analysis in environmental monitoring, petrochemical industries, and third-party testing laboratories.
    It enables fully automated injection of up to 8 gas samples per cycle, significantly improving analytical efficiency while reducing manual operation errors. The system is fully compatible with Agilent chromatography workstations and can also integrate with other GC brands via a standard “Start” trigger signal, ensuring seamless automation in gas chromatography workflows.
    With features such as inert silanized tubing, heated transfer lines, and built-in vacuum pump support, the JQ-8 ensures high sample integrity, excellent repeatability, and reliable performance for sensitive gas analysis applications.

     
    Key Features
        • Fully automated 8-channel gas sample injection system
        • Compatible with Agilent GC systems and other chromatography platforms
        • External “Start” signal enables synchronization with various GC instruments
        • Software-controlled injection program for simple and efficient operation
        • High stability with excellent repeatability and reproducibility
        • Built-in diaphragm vacuum pump for reliable sample transfer
        • Silanized inert gas pathways for corrosion resistance and low adsorption
        • Heated transfer lines prevent condensation and sample loss
        • Minimal maintenance requirements, easy to operate
        • Core components designed for long service life and industrial durability
        • Suitable for sensitive gases including sulfur-containing compounds

     
    Working Principle
    The JQ-8 Automatic Gas Sampler operates through a programmable multi-channel injection system:
        • Gas samples are loaded into 8 independent sampling channels.
        • The system uses an internal vacuum-assisted transfer mechanism to ensure stable sample intake.
        • Heated and inert silanized tubing prevents condensation and adsorption of reactive gases.
        • Upon receiving a Start signal from the GC system, the sampler sequentially injects each gas sample.
        • Software controls timing, sequence, and injection volume for each channel.
        • The system completes fully automated multi-sample injection cycles with high precision and repeatability.
    This design ensures consistent gas delivery, reduced contamination risk, and high analytical accuracy.

     
    Technical Specifications
    Parameter Specification
    Model JQ-8
    Injection Channels 8 positions
    Control Method Software program control
    External Interfaces Serial port, touch control, EVENT, BCD
    GC Compatibility Agilent GC and other brands
    Tubing 1/16” passivated stainless steel tubing
    Vacuum System Built-in diaphragm vacuum pump
    Transfer Lines Heated sample transfer lines
    Electrical Power 220 V, 50 Hz
    Power Consumption 100 W
    Net Weight 15 kg
    Dimensions 450 × 420 × 350 mm (8-channel version)
     
    Applications
    The JQ-8 Automatic Gas Sampler is widely used in:
        • Environmental air quality monitoring laboratories
        • Petrochemical gas composition analysis
        • Natural gas and refinery gas testing
        • LNG and LPG gas analysis
        • Third-party testing and certification laboratories
        • Industrial emission monitoring
        • Research institutes and universities
        • Gas chromatography (GC) analytical systems
        • Sulfur-containing gas analysis
        • Volatile organic compound (VOC) testing

     
    Comparison: JQ-8 Automatic Gas Sampler vs Manual Gas Injection
    Feature JQ-8 Automatic Gas Sampler Manual Gas Injection
    Automation Level Fully automated 8-sample injection Manual operation
    Repeatability High and consistent Operator-dependent
    Efficiency Batch processing, high throughput Slow, single-sample
    Contamination Risk Low (sealed inert system) Higher
    GC Integration Compatible with Agilent & other GC systems Limited
    Sample Handling Heated inert transfer lines No heating control
    Labor Requirement Minimal High
    Data Stability Excellent Variable
     
    FAQ
    Q1: How many gas samples can the JQ-8 handle?
    It supports 8-channel automated gas sample injection, enabling batch analysis.
    Q2: Is it compatible with Agilent GC systems?
    Yes. It is fully compatible with Agilent chromatography systems and can also connect to other GC brands via a standard start signal.
    Q3: Does it require manual operation during analysis?
    No. The JQ-8 provides fully automated injection and sequencing, requiring minimal operator intervention.
    Q4: How does it prevent gas sample loss?
    It uses heated transfer lines and inert silanized tubing to prevent condensation and adsorption.
    Q5: Is it suitable for sulfur-containing gases?
    Yes. The inert flow path is designed to handle reactive gases including sulfur compounds.

     
    Why Choose the JQ-8 Channel Automatic Gas Sampler?
    The JQ-8 Automatic Gas Sampler provides a reliable and efficient solution for multi-sample gas chromatography analysis. With 8-channel automation, GC system compatibility, heated inert pathways, and high repeatability, it significantly improves laboratory throughput and accuracy. It is an ideal choice for environmental monitoring, petrochemical analysis, and advanced GC laboratories requiring stable and fully automated gas injection performance.

     
     

     
  • FAQ
    Q1: How many gas samples can the JQ-8 handle?
    It supports 8-channel automated gas sample injection, enabling batch analysis.
    Q2: Is it compatible with Agilent GC systems?
    Yes. It is fully compatible with Agilent chromatography systems and can also connect to other GC brands via a standard start signal.
    Q3: Does it require manual operation during analysis?
    No. The JQ-8 provides fully automated injection and sequencing, requiring minimal operator intervention.
    Q4: How does it prevent gas sample loss?
    It uses heated transfer lines and inert silanized tubing to prevent condensation and adsorption.
    Q5: Is it suitable for sulfur-containing gases?
    Yes. The inert flow path is designed to handle reactive gases including sulfur compounds.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com