    Product Introduction
    The JL-SPB-1 Gypsum Board Fire Stability Tester is designed to determine the fire stability of paper-faced fire-resistant gypsum boards. It can also be used to evaluate the fire performance of other building, decorative, and interior finishing materials when applicable test methods are specified.
    The instrument uses two burners to expose a suspended specimen to controlled high-temperature flames. Dual thermocouples monitor temperature, while digital displays and automatic control support consistent test conditions. The time from flame application until specimen failure is recorded to evaluate fire stability.

     


    Performance Features
    • Dual-burner design: Applies flames to the specimen under specified test conditions.
    •   Automatic ignition: Simplifies burner ignition and test preparation.
    •  Dual-thermocouple temperature measurement: Supports monitoring of the test temperature.
    •  Digital temperature and time display: Allows operators to observe key test parameters.
    • Automatic test control: Controls the test process according to configured settings.
    • Automatic failure-time recording: Records the burning time when the specimen breaks or falls.
    •   Adjustable flame length: Flame length can be adjusted from 20 to 100 mm.
    •  Adjustable test duration: Flame application and holding times can be set within the specified timing range.
    •   Selectable hanging loads: Supports six load options from 7 N to 20 N.

     


    Working Principle
    The test specimen is drilled and conditioned under the specified environmental conditions before being suspended between two burners. The burner outlets are positioned perpendicular to the specimen surface, with a specified distance of 30 mm between each flame outlet and the board surface. A prescribed load is attached to the lower end of the specimen.
    Using coal gas or liquefied petroleum gas (LPG) as the fuel source, the burners heat the specimen. A thermocouple positioned 5 mm from the board surface monitors the temperature. The temperature is adjusted to reach 800 ± 30°C within three minutes and is maintained throughout the test.
    Timing begins when the specimen is exposed to the flames and continues until the specimen fractures or fails. The failure times of five specimens are recorded, and the shortest time is taken as the fire stability result for the group, rounded to the nearest minute according to the supplied test procedure.

     


    Technical Specifications
    Parameter Specification
    Model JL-SPB-1
    Main application Fire stability testing of paper-faced gypsum boards
    Additional applications Other building and decorative materials, subject to applicable test methods
    Power supply 220 V ±10%, 50 Hz
    Rated power 180 W
    Ignition Automatic
    Temperature measurement Dual thermocouples
    Display Digital temperature and time
    Number of burners 2
    Burner inner diameter Φ9.5 ± 0.5 mm
    Burner length Approximately 100 mm
    Air adjustment nut 10 mm
    Burner head diameter 40 ± 1 mm
    Burner orifice diameter 2.5 ± 0.1 mm
    Adjustable flame length 20–100 mm
    Flame application and holding time Adjustable from 0 to 99 min 99 s
    Test process Automatic control
    Specimen failure recording Automatic burning-time recording
    Fuel gas Coal gas or liquefied petroleum gas (LPG)
    Flow adjustment range 100–1000 mL/min
    Timer resolution 0.1 s
    Standard test temperature 800 ± 30°C
    Maximum temperature 900°C
    Temperature accuracy class Class 1, as specified by the source
    Temperature stabilization time Less than 3 minutes to reach 800 ± 30°C
    Specimen dimensions 300 × 50 mm (length × width)
    Specimen holes Holes drilled 25 mm from each side, according to the supplied description
    Hanging loads 7, 10, 12, 15, 17, 20 N
    Instrument dimensions 700 × 300 × 600 mm (W × D × H)
    Packaging dimensions 800 × 420 × 700 mm (W × D × H)
     


    Application Scenarios
    • Gypsum board manufacturers: Evaluate the fire stability of paper-faced gypsum boards during product development and quality control.
    • Building material laboratories: Conduct specified fire stability tests on construction materials.
    •  Decorative material testing: Assess the fire performance of applicable interior finishing and decorative materials.
    •  Product research and development: Compare the performance of different board formulations and product designs.
    •  Quality inspection facilities: Record specimen failure times under controlled thermal exposure conditions.

     


    JL-SPB-1 vs. General Fire Testing Equipment
    Comparison Item JL-SPB-1 Gypsum Board Fire Stability Tester General Fire Testing Equipment
    Primary purpose Evaluates gypsum board fire stability through time to specimen failure Varies by test method and equipment type
    Heating method Two gas burners May use burners, radiant heat, furnaces, or other methods
    Temperature monitoring Dual thermocouples Depends on configuration
    Target temperature 800 ± 30°C; maximum 900°C Depends on the applicable test
    Specimen loading Selectable loads of 7–20 N Depends on the test method
    Timing Digital timing with 0.1 s resolution Depends on configuration
    Failure-time recording Automatic May be manual or automatic
    Typical applications Paper-faced gypsum boards and other suitable building materials Broader range of fire and combustion tests
     


    Frequently Asked Questions
    Q1: What is the JL-SPB-1 used for?
    It is primarily used to determine the fire stability of paper-faced gypsum boards. It may also be used for other building and decorative materials where the relevant test method applies.
    Q2: What temperature is used during testing?
    The specified test temperature is 800 ± 30°C, with a maximum instrument temperature of 900°C.
    Q3: How many burners does the instrument have?
    It has two burners, each with an inner diameter of 9.5 ± 0.5 mm and a length of approximately 100 mm.
    Q4: Does the JL-SPB-1 support automatic ignition?
    Yes. The instrument features automatic ignition and automatic test-process control.
    Q5: How is fire stability evaluated?
    The time from flame application until specimen failure is recorded for five specimens. According to the supplied procedure, the shortest recorded time is used as the group's fire stability result.
    Q6: What fuel gas is required?
    Coal gas or liquefied petroleum gas (LPG) can be used. The source recommends using gas of suitable quality. Confirm the approved fuel, pressure, flow, and connection requirements before operation.
    Q7: What specimen size is required?
    The specified specimen dimensions are 300 × 50 mm. The source describes drilling holes 25 mm from each side; confirm the complete hole arrangement against the applicable test method.
    Q8: What hanging loads are available?
    The available loads are 7 N, 10 N, 12 N, 15 N, 17 N, and 20 N.
    Q9: What is the timer resolution?
    The stated timer resolution is 0.1 seconds. The reported group fire stability result is rounded to the nearest minute according to the supplied procedure.


  • Frequently Asked Questions
    Q1: What is the JL-SPB-1 used for?
    It is primarily used to determine the fire stability of paper-faced gypsum boards. It may also be used for other building and decorative materials where the relevant test method applies.
    Q2: What temperature is used during testing?
    The specified test temperature is 800 ± 30°C, with a maximum instrument temperature of 900°C.
    Q3: How many burners does the instrument have?
    It has two burners, each with an inner diameter of 9.5 ± 0.5 mm and a length of approximately 100 mm.
    Q4: Does the JL-SPB-1 support automatic ignition?
    Yes. The instrument features automatic ignition and automatic test-process control.
    Q5: How is fire stability evaluated?
    The time from flame application until specimen failure is recorded for five specimens. According to the supplied procedure, the shortest recorded time is used as the group's fire stability result.
    Q6: What fuel gas is required?
    Coal gas or liquefied petroleum gas (LPG) can be used. The source recommends using gas of suitable quality. Confirm the approved fuel, pressure, flow, and connection requirements before operation.
    Q7: What specimen size is required?
    The specified specimen dimensions are 300 × 50 mm. The source describes drilling holes 25 mm from each side; confirm the complete hole arrangement against the applicable test method.
    Q8: What hanging loads are available?
    The available loads are 7 N, 10 N, 12 N, 15 N, 17 N, and 20 N.
    Q9: What is the timer resolution?
    The stated timer resolution is 0.1 seconds. The reported group fire stability result is rounded to the nearest minute according to the supplied procedure.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com