Position: Home > > Lab general equipment > Sample preparation and digestion > Electric heating digestion > HYP-308 Eight-Hole Intelligent Digestion Furnace

HYP-308 Eight-Hole Intelligent Digestion Furnace

Product ID:SYZYXJdrxj033

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberHYP-308
    Brand NameSHXIANJIAN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    HYP-308 Eight-Hole Intelligent Digestion Furnace
    Product Introduction
    The HYP-308 Eight-Hole Intelligent Digestion Furnace is a high-precision laboratory digestion system designed for Kjeldahl nitrogen determination and sample pre-treatment. It supports multi-sample batch digestion with stable temperature control, intelligent programming, and safe operation.
    With an advanced ceramic furnace core heating system, the HYP-308 ensures complete and uniform digestion of samples, making it widely used in food, dairy, soil, fertilizer, and environmental laboratories.

     
    Performance Features
    The HYP-308 intelligent digestion furnace offers high efficiency and safety for routine laboratory digestion:

        • High-precision temperature control with continuous adjustment and ±1°C stability
        • Ceramic furnace core heating ensures uniform and complete sample digestion
        • Independent heat isolation design protects control panel from high-temperature radiation
        • Over-temperature protection system automatically cuts power and alarms when exceeding set limit
        • 2.5-inch LCD blue screen display showing real-time temperature and countdown timer
        • Programmable heating curves (linear & curve heating modes) for different sample types
        • Auto-stop and alarm function after digestion completion
        • Integrated exhaust gas system allows operation without fume hood in many cases
        • Complete accessory configuration for easy sample handling and operation
     
    Working Principle
    The HYP-308 digestion furnace operates using controlled ceramic core heating combined with programmed temperature curves.

        • Samples in digestion tubes are placed into heating holes.
        • The ceramic heating module provides uniform thermal energy.
        • The system follows pre-set linear or curve heating programs.
        • Nitrogen-containing compounds are digested under high temperature and catalysts.
        • Exhaust gases are safely discharged through the sealed PTFE exhaust system.
        • The system automatically stops and alarms after completion.
    This ensures consistent Kjeldahl digestion efficiency and reduces human operation errors.
     
    Technical Parameters
    Parameter Specification
    Nitrogen measurement range 0.1 mg – 240.0 mg N
    Sample capacity 8 samples per batch
    Digestion time ~45 min/batch
    Digestion tube volume 250 mL
    Temperature range Room temperature – 600°C
    Temperature accuracy ±1°C
    Average heating rate 30°C/min
    Control mode Programmable (curve & linear heating)
    Heating system Ceramic furnace core heating
    Sealing material PTFE (polytetrafluoroethylene)
    Insulation design Split air duct thermal isolation
    Display 2.5-inch LCD (temperature + timer countdown)
    Safety system Over-temperature protection + automatic shutdown
    Power supply 220V ±10%, 50–60 Hz
    Rated power 2600 W
    Dimensions 430 × 370 × 190 mm
    Weight 14 kg
     
    Application Areas
    The HYP-308 digestion furnace is widely used in:

        • Food and beverage nitrogen analysis (milk, protein testing)
        • Agricultural soil and fertilizer testing
        • Environmental monitoring laboratories
        • Chemical and pharmaceutical analysis
        • Academic and research institutions
        • Quality control laboratories in food industry
        • Kjeldahl nitrogen digestion before distillation analysis
     
    Comparison Table
    Feature HYP-308 Intelligent Digestion Furnace Conventional Digestion Block
    Temperature control ±1°C high precision Moderate accuracy
    Heating system Ceramic furnace core Metal heating block
    Programming Curve & linear control Limited or manual
    Safety protection Over-temp auto cut-off Basic protection only
    Digestion uniformity High consistency Medium
    Operation interface LCD digital display Analog or simple display
    Exhaust handling PTFE sealed exhaust system Open or basic venting
    Batch capacity 8 samples 4–6 samples
     
    FAQ
    Q1: What is the HYP-308 digestion furnace mainly used for?
    A: It is mainly used for Kjeldahl nitrogen digestion in food, soil, fertilizer, and chemical analysis.
    Q2: Can it be used for milk and protein testing?
    A: Yes, it is highly suitable for dairy protein and nitrogen determination.
    Q3: Does it require a fume hood?
    A: In many cases, the built-in exhaust system reduces the need for a fume hood.
    Q4: How many samples can be processed at once?
    A: It can process 8 samples per batch.
    Q5: Is the temperature stable during operation?
    A: Yes, it offers ±1°C precise temperature control with stable heating performance.
    Q6: What safety features are included?
    A: Over-temperature protection, automatic shutdown, and alarm system are integrated.

     
    Conclusion
    The HYP-308 Eight-Hole Intelligent Digestion Furnace is a reliable, high-efficiency laboratory digestion system designed for accurate nitrogen digestion and Kjeldahl analysis. With advanced ceramic heating, programmable control, and strong safety features, it significantly improves laboratory digestion efficiency and reproducibility.

     

     
     
  • FAQ
    Q1: What is the HYP-308 digestion furnace mainly used for?
    A: It is mainly used for Kjeldahl nitrogen digestion in food, soil, fertilizer, and chemical analysis.
    Q2: Can it be used for milk and protein testing?
    A: Yes, it is highly suitable for dairy protein and nitrogen determination.
    Q3: Does it require a fume hood?
    A: In many cases, the built-in exhaust system reduces the need for a fume hood.
    Q4: How many samples can be processed at once?
    A: It can process 8 samples per batch.
    Q5: Is the temperature stable during operation?
    A: Yes, it offers ±1°C precise temperature control with stable heating performance.
    Q6: What safety features are included?
    A: Over-temperature protection, automatic shutdown, and alarm system are integrated.

     
    Conclusion
    The HYP-308 Eight-Hole Intelligent Digestion Furnace is a reliable, high-efficiency laboratory digestion system designed for accurate nitrogen digestion and Kjeldahl analysis. With advanced ceramic heating, programmable control, and strong safety features, it significantly improves laboratory digestion efficiency and reproducibility.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us