HX-101E small animal ventilator For animal experiments

Product ID:SHDWhxj007

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberHX-101E
    Brand NameYM
    Payment TermsT/T, paypal
    Brief introduction
    The animal ventilator can give the correct tidal volume does not exceed the pressure of the lungs for animals include : mice , rats , guinea pigs, rabbits and other small animals . Product design scientific , reasonable structure, low noise , the use of digital rotary encoder adjustment tidal volume and respiratory rate, adjustable and flexible, easy to use, display cabinet with pressure dial responsive, intuitive observation .
    Features
    1. Suitable for mice, rats , rabbits small experimental animals ;
    2. adapt to a wide voltage input can be used for ultra-quiet table HF ;
    3. Product design scientific , reasonable structure, low noise , appearance ;
    4. can be precisely adjusted tidal volume ventilator , the adjustment process to display the current value in real-time adjustment of moisture ;
    5. Select the button provides animal animal reference experimental parameters , easy setup ;

    6. subject to change operating parameters during operation of the ventilator , press the start button to set the new parameters to take effect ;
    7. Use the numeric keys to adjust the rotary encoder and tidal volume and respiratory rate, adjustable flexible , easy to use ;
    8. digital display clear and intuitive ;
    9. air or other gas as the gas source , no high-pressure gas , easy to use ;

    Technical parameters
    Tidal volume 0.1~99.9ml adjustable
    respiratory ratio 1~5:1~5
    Respiratory rate 1 to 200 beats / min adjustable
    Animal Parameter Reference button Mice (20g), rat (200g), rabbit (2kg)
    Mice Parameter Reference Setting Range Frequency: 80 to 200 , tidal volume : 0.1 ~ 20ml
    Rat Parameter Reference Setting Range Frequency: 50 to 200 , tidal volume : 5 ~ 50ml
    Rabbit Parameter Reference Setting Range Frequency: 20 to 60, tidal volume : 20 ~ 99.9 ml
    Input voltage 85~264VAC,120~370VDC
    Working temperature 0 ~ 50
    Relative humidity 20 ~ 80% RH
    Reliability MTBF ≥ 10000h
     
  • The animal ventilator can give the correct tidal volume does not exceed the pressure of the lungs for animals include : mice , rats , guinea pigs, rabbits and other small animals . Product design scientific , reasonable structure, low noise , the use of digital rotary encoder adjustment tidal volume and respiratory rate, adjustable and flexible, easy to use, display cabinet with pressure dial responsive, intuitive observation .
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com