    Product Introduction
    The HTY-305G Microbial Limit Testing Instrument is designed according to relevant pharmacopoeia requirements for microbial limit testing of pharmaceuticals, water, beverages and other products.
    The instrument uses a high-performance built-in diaphragm pump for direct liquid discharge, eliminating the need for a separate filtration flask. By combining different pump heads with dedicated filter cups or limit culture devices, the HTY-305G can form a complete membrane filtration system for microbiological testing.
    During testing, the sample solution passes through a membrane filter. Microorganisms in the sample are retained on the membrane, after which the membrane is cultured to allow visible colonies to form. The colonies are then counted to determine the microbial content of the tested sample.

     


    Performance Features
    •Built-in high-performance diaphragm pump: Low-noise direct liquid discharge eliminates the need for a filtration flask.
    • Touchscreen operation: Intuitive human-machine interface clearly displays operating status and simplifies operation.
    •  Date and time display: Facilitates test timing and laboratory operation.
    •  Flexible pump-head configuration: One main unit can work with two types of pump heads.
    •  Three pump heads: Can be started and stopped simultaneously or controlled independently for improved testing efficiency.
    • Easy pump-head replacement: Pump heads are designed for convenient installation and removal.
    •  121°C moist-heat sterilization: Pump heads can be sterilized by moist heat at 121°C.
    •  Rapid flame sterilization: Pump heads can also be rapidly sterilized using a flame torch for continuous laboratory testing.
    • Stainless-steel housing: Mirror-polished stainless steel provides a smooth surface that is easy to clean and disinfect.
    •  High flow rate: Single pump-head flow rate is ≥1200 mL/min.
    •  Compact design: 230 × 380 × 135 mm housing saves laboratory bench space.

     


    Working Principle
    The HTY-305G uses the membrane filtration method for microbial limit testing.
    First, the prepared test solution is introduced into the filtration assembly. The built-in diaphragm pump drives the liquid through a suitable microporous membrane. Microorganisms contained in the sample are retained on the membrane while the filtered liquid is discharged directly.
    The membrane containing the retained microorganisms is then transferred or handled according to the applicable testing procedure and cultured under specified conditions. Microbial colonies become visible after cultivation and can be counted to determine the microbial content of the sample.
    The instrument supports different pump-head configurations to accommodate S60 culture devices and F47 filter cups with Φ47 mm microporous membranes.

     


    Technical Specifications
    Parameter Specification
    Model HTY-305G
    Product Name Microbial Limit Testing Instrument
    Testing Method Membrane filtration
    Pump Type Built-in high-performance diaphragm pump
    Number of Pump Heads Up to 3, depending on configuration
    Pump Control Simultaneous or independent control
    Flow Rate ≥1200 mL/min per pump head
    Suitable Consumables S60 culture device, F47 filter cup
    Filter Membrane Φ47 mm microporous membrane
    Pump Head Sterilization 121°C moist-heat sterilization; flame sterilization
    Display/Control Touchscreen
    Date/Time Supported
    Noise ≤65 dB(A) under load
    Power 90 W
    Power Supply AC 220 V / 50 Hz
    Housing Mirror-polished stainless steel
    Dimensions 230 × 380 × 135 mm
    Weight Approx. 10 kg with PF47 pump head / 12 kg with PS60 pump head
     


    Application Scenarios
    The HTY-305G microbial limit testing instrument is suitable for microbiological testing in:
    Pharmaceutical Industry
    •  Purified water
    •  Water for injection
    •  Pharmaceuticals and pharmaceutical preparations
    •  Microbial limit testing of pharmaceutical products
    Disease Control and Water Testing
    •  Air-conditioning condensate
    •  Drinking water
    •  Total bacterial count testing
    •  Pathogenic microorganism testing
    Food and Beverage Industry
    •  Beverages
    •  Mineral water
    •  Purified water
    •  Microbial colony count testing
    Chemical Industry
    •  Industrial water samples requiring microbiological testing
    •  Process and laboratory water microbiological analysis

     


    HTY-305G vs. Conventional Membrane Filtration Setup
    Feature HTY-305G Conventional Filtration Setup
    Pump Built-in diaphragm pump Usually separate
    Filtration Flask Not required May be required
    Operation Touchscreen Depends on setup
    Liquid Discharge Direct discharge Separate vacuum/discharge system may be needed
    Pump Heads Multiple configurable heads Depends on equipment
    Pump Control Simultaneous or independent Depends on setup
    Sterilization 121°C moist heat / flame sterilization for pump heads Depends on components
    Housing Mirror-polished stainless steel Depends on equipment
    Flow Rate ≥1200 mL/min per pump head Depends on setup
    Application Pharmaceutical, water, food and chemical testing Depends on configuration
     


    FAQ
    1.  What is the HTY-305G used for?
    The HTY-305G is designed for microbial limit testing of pharmaceuticals, water, beverages and other products using membrane filtration.
    2. What testing principle does the instrument use?
    It uses the membrane filtration method, in which microorganisms are retained on a microporous membrane and subsequently cultured and counted.
    3. Does the HTY-305G require a filtration flask?
    No. Its built-in diaphragm pump provides direct liquid discharge, eliminating the need for a separate filtration flask.
    4. What is the flow rate of the pump?
    The specified flow rate is ≥1200 mL/min per pump head.
    5. Can the pump heads be sterilized?
    Yes. The pump heads can undergo 121°C moist-heat sterilization and can also be rapidly sterilized using a flame torch.
    6. How many pump heads can the instrument support?
    The supplied configuration supports three pump heads, which can be operated simultaneously or independently. The main unit can accommodate two types of pump heads.
    7. Which consumables are compatible with the HTY-305G?
    The specified consumables include the S60 culture device and F47 filter cup with a Φ47 mm microporous membrane.
    8. What industries can use this microbial limit tester?
    It is suitable for pharmaceutical, disease-control, water, food and beverage, and chemical applications requiring microbial testing.
    9. Is the instrument easy to clean?
    Yes. The housing uses mirror-polished stainless steel with a smooth surface designed to facilitate cleaning and disinfection.
     
  • FAQ
    1.  What is the HTY-305G used for?
    The HTY-305G is designed for microbial limit testing of pharmaceuticals, water, beverages and other products using membrane filtration.
    2. What testing principle does the instrument use?
    It uses the membrane filtration method, in which microorganisms are retained on a microporous membrane and subsequently cultured and counted.
    3. Does the HTY-305G require a filtration flask?
    No. Its built-in diaphragm pump provides direct liquid discharge, eliminating the need for a separate filtration flask.
    4. What is the flow rate of the pump?
    The specified flow rate is ≥1200 mL/min per pump head.
    5. Can the pump heads be sterilized?
    Yes. The pump heads can undergo 121°C moist-heat sterilization and can also be rapidly sterilized using a flame torch.
    6. How many pump heads can the instrument support?
    The supplied configuration supports three pump heads, which can be operated simultaneously or independently. The main unit can accommodate two types of pump heads.
    7. Which consumables are compatible with the HTY-305G?
    The specified consumables include the S60 culture device and F47 filter cup with a Φ47 mm microporous membrane.
    8. What industries can use this microbial limit tester?
    It is suitable for pharmaceutical, disease-control, water, food and beverage, and chemical applications requiring microbial testing.
    9. Is the instrument easy to clean?
    Yes. The housing uses mirror-polished stainless steel with a smooth surface designed to facilitate cleaning and disinfection.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com