Position: Home > > Life science instrument and equipment > Microbial detection apparatus > Microbial detection system > HTY-301 Microbial Detection Filtration Manifold

HTY-301 Microbial Detection Filtration Manifold

Product ID:SHWSWjc032

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberHTY-301
    Brand NameZJTAILIN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    HTY-301 Microbial Detection Filtration Manifold
    Product Introduction
    The HTY-301 Microbial Detection Filtration Manifold is a professional microbiological filtration platform designed for microbial limit testing and membrane filtration analysis. Used together with the S60 Microbial Detection Culture Unit, it forms a complete microbial detection filtration system widely applied in pharmaceutical, food, water quality, and chemical industries.
    Based on the membrane filtration method, the sample solution is filtered under vacuum pressure, allowing microorganisms to be retained on the membrane surface. The membrane is then directly cultured within the detection unit without transfer, minimizing contamination risks while improving testing efficiency and colony recovery.

     
    Features
        • Stainless steel construction for durability and easy cleaning.
        • Entire filtration manifold can be sterilized by moist heat (autoclaving).
        • Sterile-packaged S60 culture units ensure convenient operation.
        • Three filtration heads can operate simultaneously or independently.
        • Direct pouring of solid culture media onto the membrane without membrane transfer.
        • Eliminates Petri dish preparation and membrane placement procedures.
        • Large 60 mm membrane diameter provides more counting area for high microbial load samples.
        • Suitable for routine microbial limit testing and microbiological quality control.
     
    Working Principle
    The HTY-301 filtration manifold operates according to the membrane filtration method:

        • The sample is introduced into the S60 microbial detection culture unit.
        • A vacuum pump creates negative pressure to filter the sample.
        • Microorganisms are captured on the membrane filter while the liquid passes through.
        • After filtration, culture medium is poured directly onto the reverse side of the membrane.
        • Once the medium solidifies, the culture unit forms a sealed incubation chamber.
        • Under controlled incubation conditions, retained microorganisms grow into visible colonies.
        • Colonies are counted and identified for microbial analysis and quality assessment.
     
    Technical Specifications
    Parameter Specification
    Model HTY-301
    Product Type Microbial Detection Filtration Manifold
    Compatible Consumable S60 Microbial Detection Culture Unit
    Filtration Heads 3
    Head Operation Simultaneous or Independent Control
    Material Stainless Steel
    Sterilization Method Autoclavable (Moist Heat Sterilization)
    Membrane Diameter 60 mm
    Weight 5 kg
    Dimensions (L × W × H) 40.5 × 12.5 × 13 cm
    Filtration Principle Membrane Filtration Method
     
    Applications

    Pharmaceutical Industry

        • Purified water testing
        • Water for injection (WFI) testing
        • Active pharmaceutical ingredient (API) microbial limit testing
        • Oral liquids, tablets, capsules, biologics, and pharmaceutical preparations
    Public Health & CDC Laboratories
        • Drinking water microbiological analysis
        • Air-conditioning condensate water testing
        • Pathogen monitoring and bacterial count determination
    Food & Beverage Industry
        • Beverage microbial testing
        • Mineral water quality inspection
        • Purified water microbiological examination
        • Total viable count (TVC) analysis
    Chemical Industry
        • Process water microbial monitoring
        • Industrial water microbiological assessment
        • Quality control testing for microbial contamination
     
    Comparison with Traditional Membrane Filtration Systems
    Feature HTY-301 Filtration Manifold Traditional Filtration System
    Filtration Heads 3 Independent Heads Usually Single Head
    Workflow Efficiency High Moderate
    Membrane Transfer Required No Yes
    Direct Media Pouring Yes No
    Contamination Risk Low Higher
    Colony Counting Area Large 60 mm Membrane Smaller Membrane Area
    Autoclavable Structure Yes Depends on Model
    Routine QC Testing Excellent Standard
     
    FAQ
    1. What is the HTY-301 used for?
    The HTY-301 is designed for microbial limit testing and microbiological analysis using the membrane filtration method in pharmaceutical, food, water, and chemical laboratories.
    2. Which culture unit is compatible with the HTY-301?
    The system is specifically designed for use with the S60 Microbial Detection Culture Unit.
    3. Can all three filtration heads operate at the same time?
    Yes. The three heads can work simultaneously to improve throughput or be controlled independently for flexible operation.
    4. Does the membrane need to be transferred after filtration?
    No. The system allows direct culture medium pouring onto the membrane, eliminating membrane transfer and reducing contamination risks.
    5. Is the filtration manifold autoclavable?
    Yes. The stainless steel manifold can be sterilized using moist heat sterilization (autoclaving).
    6. Why use a 60 mm membrane filter?
    The larger membrane diameter provides a greater colony counting area, making it particularly suitable for samples with higher microbial loads.
    7. What industries commonly use the HTY-301?
    Pharmaceutical manufacturing, food and beverage production, public health laboratories, water quality monitoring facilities, and chemical processing plants.
    8. What are the advantages of membrane filtration for microbial testing?
    Membrane filtration offers high microorganism recovery rates, efficient sample processing, accurate colony counting, and compliance with microbial limit testing standards.

     
    Conclusion
    The HTY-301 Microbial Detection Filtration Manifold is a reliable and efficient membrane filtration solution for microbial limit testing. Featuring three independently controlled filtration heads, autoclavable stainless steel construction, direct culture capability, and compatibility with the S60 culture unit, it provides an ideal platform for pharmaceutical microbiology, water quality testing, food safety analysis, and laboratory quality control applications.
     


  • FAQ
    1. What is the HTY-301 used for?
    The HTY-301 is designed for microbial limit testing and microbiological analysis using the membrane filtration method in pharmaceutical, food, water, and chemical laboratories.
    2. Which culture unit is compatible with the HTY-301?
    The system is specifically designed for use with the S60 Microbial Detection Culture Unit.
    3. Can all three filtration heads operate at the same time?
    Yes. The three heads can work simultaneously to improve throughput or be controlled independently for flexible operation.
    4. Does the membrane need to be transferred after filtration?
    No. The system allows direct culture medium pouring onto the membrane, eliminating membrane transfer and reducing contamination risks.
    5. Is the filtration manifold autoclavable?
    Yes. The stainless steel manifold can be sterilized using moist heat sterilization (autoclaving).
    6. Why use a 60 mm membrane filter?
    The larger membrane diameter provides a greater colony counting area, making it particularly suitable for samples with higher microbial loads.
    7. What industries commonly use the HTY-301?
    Pharmaceutical manufacturing, food and beverage production, public health laboratories, water quality monitoring facilities, and chemical processing plants.
    8. What are the advantages of membrane filtration for microbial testing?
    Membrane filtration offers high microorganism recovery rates, efficient sample processing, accurate colony counting, and compliance with microbial limit testing standards.

     
    Conclusion
    The HTY-301 Microbial Detection Filtration Manifold is a reliable and efficient membrane filtration solution for microbial limit testing. Featuring three independently controlled filtration heads, autoclavable stainless steel construction, direct culture capability, and compatibility with the S60 culture unit, it provides an ideal platform for pharmaceutical microbiology, water quality testing, food safety analysis, and laboratory quality control applications.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com