HTY-102S Microbial Detection System

Product ID:SHWSWjc057

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberHTY-102S
    Brand NameZJTAILIN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    HTY-102S Microbial Detection System
    Product Introduction
    HTY-102S Microbial Detection System is a professional membrane filtration microbial testing instrument designed according to pharmacopoeia requirements for microbial limit testing. It is mainly used for the detection of microbial contamination levels in pharmaceutical products, purified water, injection water, food, beverages, and various aqueous samples.
    The system consists of a microbial detection unit and compatible consumables. By using membrane filtration technology, microorganisms in the test solution are retained on the filter membrane, then cultured to form visible colonies for counting and quantitative microbial analysis.
    The HTY-102S adopts a single-channel design with an imported diaphragm pump, direct wastewater discharge structure, and interchangeable pump heads. It can be combined with different filter cups or microbial culture devices to build a complete membrane filtration testing system.

     

    Performance Features
    • Imported diaphragm pump with reliable performance
    Built-in imported diaphragm pump provides stable operation, low noise, and long service life. The direct drainage design simplifies operation and improves laboratory efficiency.
    • SIP sterilization function
    The integrated SIP (Steam-In-Place) sterilization function supports standardized cleaning and disinfection procedures according to system prompts.
    • Touchscreen operation interface
    Equipped with a color LCD display and tempered glass touch panel for convenient operation and clear parameter visualization.
    • Optional printing function
    Supports optional printer connection to record instrument operation information and testing data for laboratory management and traceability.
    • Automatic timing control
    The pump operating time can be independently set. After reaching the preset time, the system automatically stops operation.
    • Flexible pump head compatibility
    One main unit can work with four different types of pump heads, supporting various filtration applications.
    • Easy sterilization and maintenance
    Pump heads feature quick installation and removal. They can withstand 121℃ steam sterilization, and continuous experimental sterilization can be performed quickly using a flame torch.
    • High-quality stainless steel structure
    The instrument body is manufactured from 316L stainless steel with mirror polishing technology, providing a smooth, corrosion-resistant, and easy-to-clean surface.
    • Anti-backflow protection design
    The pump head integrates a one-way valve to prevent liquid backflow and reduce contamination risks.

     

    Working Principle
    The HTY-102S Microbial Detection System uses membrane filtration technology.
    During testing, the sample solution passes through a sterile membrane filter under vacuum pressure generated by the diaphragm pump. Microorganisms contained in the sample are trapped on the membrane surface, while the filtered liquid is discharged.
    After filtration, the membrane is transferred to a suitable culture medium. Following incubation, microorganisms form visible colonies that can be counted to determine the microbial contamination level of the tested sample.
    This method provides high sensitivity, reliable results, and is widely used for microbial limit testing and quality control applications.

     

    Technical Parameters
    Parameter Specification
    Product Model HTY-102S
    Power Supply AC220V / 50Hz
    Noise Level ≤65dB(A) (with load)
    Dimensions 20.0 × 23.5 × 11.0 cm
    Power Consumption 60W
    Flow Rate 1500mL/min (single pump)
    Body Material 316L Stainless Steel
    Weight 4kg (with PF47/PB47 pump head)
    Weight 4.5kg (with PF60 pump head)
    Weight 5kg (with PS60 pump head)
    Compatible Consumables S60 culture device, F47 filter cup, F60-R250 filter cup, F47B series filter cup
     

    Compatible Consumables
    The HTY-102S Microbial Detection System supports multiple filtration accessories to meet different testing requirements:
    Consumable Application
    S60 Culture Device Microbial culture and filtration testing
    F47 Filter Cup Standard membrane filtration applications
    F60-R250 Filter Cup Large-volume sample filtration
    F47B Series Filter Cup Routine microbial detection
     

    Applications
    Pharmaceutical Industry
    Used for microbial limit testing of:
    • Purified water
    • Water for injection (WFI)
    • Pharmaceutical raw materials
    • Drug products and preparations
    The system helps pharmaceutical laboratories perform microbial quality control according to pharmacopoeia requirements.
    Disease Control and Public Health
    Suitable for microbial analysis of:
    • Air-conditioning condensate water
    • Drinking water
    • Environmental water samples
    • Pathogenic microorganism detection
    Food and Beverage Industry
    Used for microbial testing of:
    • Beverages
    • Mineral water
    • Purified drinking water
    • Food-related liquid samples
    Chemical Industry
    Applicable for microbial testing of various industrial water samples and liquid products requiring microbiological analysis.

     

    Advantages Compared with Traditional Microbial Testing Methods
    Feature HTY-102S Microbial Detection System Traditional Microbial Testing
    Detection Method Membrane filtration technology Direct culture methods
    Operation Automated pumping and timing control Manual operation required
    Sterilization SIP function and sterilizable pump heads Additional sterilization steps
    Material 316L stainless steel structure Usually standard materials
    Data Management Optional printing records Limited traceability
    Application Range Pharmaceutical, food, water, chemical testing Limited application scenarios
     

    Frequently Asked Questions (FAQ)
    1. What is the HTY-102S Microbial Detection System used for?
    The HTY-102S is mainly used for microbial limit testing and bacterial contamination analysis in pharmaceutical water, injection water, food, beverages, and industrial liquid samples.
    2. What detection method does the HTY-102S use?
    The instrument uses membrane filtration technology. Microorganisms are captured on a membrane filter and cultured for colony counting.
    3. Is the HTY-102S suitable for pharmaceutical laboratories?
    Yes. The instrument is designed according to pharmacopoeia-related requirements and is widely used for microbial testing in pharmaceutical quality control laboratories.
    4. Can the pump head be sterilized?
    Yes. The pump head can be quickly removed and sterilized by 121℃ moist heat sterilization. During continuous testing, rapid flame sterilization is also supported.
    5. What consumables are compatible with the HTY-102S?
    The system supports S60 culture devices, F47 filter cups, F60-R250 filter cups, and F47B series filter cups.
    6. How should users choose a microbial detection system?
    Users should consider sample type, required testing standards, filtration volume, sterilization requirements, and laboratory data management needs. The HTY-102S is suitable for laboratories requiring reliable membrane filtration microbial testing with flexible accessories.

     

    Product Summary
    HTY-102S Microbial Detection System is a compact, reliable, and easy-to-maintain membrane filtration instrument for microbial limit testing. With an imported diaphragm pump, SIP sterilization capability, 316L stainless steel construction, and versatile filter compatibility, it provides an efficient solution for pharmaceutical, food, water quality, and chemical microbiological analysis.

     
     
  • Frequently Asked Questions (FAQ)
    1. What is the HTY-102S Microbial Detection System used for?
    The HTY-102S is mainly used for microbial limit testing and bacterial contamination analysis in pharmaceutical water, injection water, food, beverages, and industrial liquid samples.
    2. What detection method does the HTY-102S use?
    The instrument uses membrane filtration technology. Microorganisms are captured on a membrane filter and cultured for colony counting.
    3. Is the HTY-102S suitable for pharmaceutical laboratories?
    Yes. The instrument is designed according to pharmacopoeia-related requirements and is widely used for microbial testing in pharmaceutical quality control laboratories.
    4. Can the pump head be sterilized?
    Yes. The pump head can be quickly removed and sterilized by 121℃ moist heat sterilization. During continuous testing, rapid flame sterilization is also supported.
    5. What consumables are compatible with the HTY-102S?
    The system supports S60 culture devices, F47 filter cups, F60-R250 filter cups, and F47B series filter cups.
    6. How should users choose a microbial detection system?
    Users should consider sample type, required testing standards, filtration volume, sterilization requirements, and laboratory data management needs. The HTY-102S is suitable for laboratories requiring reliable membrane filtration microbial testing with flexible accessories.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com