HM-P08 African swine fever detection instrument Introduction: The HM-P08 African swine fever detection instrument is mainly used to run real-time fluorescence quantitative PCR experiments. Through fluorescence excitation and collection, the experimental process is monitored in real time, and the experimental data is plotted into fluorescence curves, which are presented in real time on the instrument display interface. The experimental data is fitted and analyzed, and finally a PDF format experimental report can be generated. Fast and accurate qualitative and quantitative analysis of target nucleic acids contained in biological samples taken from other animals (such as blood, body fluids, etc.), as well as standard curve, melting curve, genotyping analysis, etc. for special samples. Features: 1. Small size, light weight, and easy to carry. Easily meet the needs of outdoor experiments. 2. Built in 7-inch high-definition capacitive screen PDA, touch screen operation, simple and fast. 3. Marlow high-quality Peltier refrigeration sheets, combined with the German high-end PT1000 temperature sensor and the temperature control mode of the electric resistance heating compensation edge, have a heating rate of 7 ℃ and a cooling rate of 5 ℃, greatly reducing the experimental time. 4. Fast lighting mode for the entire board for 3 seconds to ensure consistency in the hole positions of the experimental results. 5. Simple and intuitive software guidance makes it easy to start detection experiments. Technical parameters: Sample capacity: 8x0.2ml, supports 8-way tubing Applicable consumables: Common transparent PCR consumables, 8x0.2ml tube, 0.2ml single tube Reaction system: 5-120ul reaction mode system Heating/cooling module: imported semiconductor thermoelectric module Temperature control range: 4 ° C-99 ℃ Average rate of temperature rise and fall: ≥ 2 ° C/second Temperature control accuracy: ≤ ± 0.1 ° C Temperature uniformity: ≤ ± 0.2 ° C Number of temperature control areas: multiple points (2 points) Gradient number: 0 Gradient temperature range: None Gradient hole count: None Excitation light source: maintenance free LED Excitation wavelength range: 400-700nm Detection component: imported photodetector Number of detection channels: Standard 1 channel (FAM), High configuration (optional) (FAM, VIC) Applicable dyes and probes: FAM/SYBR Green I, VIC/HEX/CY3 (optional), ROX/Texas Red (optional), Cy5, TAMARA (optional) Noise:<45 dB Screen size: 7 inches (HD) Hot cover: automatic pressure regulation Appearance dimensions: 290 (W) * 308 (L) * 130 (H) Box size: 75 L * 38 W * 19 H cm Net weight: approximately 3Kg
Introduction: The HM-P08 African swine fever detection instrument is mainly used to run real-time fluorescence quantitative PCR experiments. Through fluorescence excitation and collection, the experimental process is monitored in real time, and the experimental data is plotted into fluorescence curves, which are presented in real time on the instrument display interface. The experimental data is fitted and analyzed, and finally a PDF format experimental report can be generated. Fast and accurate qualitative and quantitative analysis of target nucleic acids contained in biological samples taken from other animals (such as blood, body fluids, etc.), as well as standard curve, melting curve, genotyping analysis, etc. for special samples.