    The HH-3658C Computerized Cryostat & Paraffin Microtome is a dual-purpose tissue sectioning system that integrates the HHQ-3658 Computerized Microtome with the HH-III Intelligent Rapid Freezing System. Designed for both rapid frozen sectioning and routine paraffin sectioning, it provides laboratories with two essential histology techniques in one compact instrument.
    Built with advanced nanomaterial technology, an intelligent LCD control system, and a high-precision stepper motor, the HH-3658C offers accurate thickness adjustment, stable cutting performance, and user-friendly operation. Automatic temperature control, rapid refrigeration recovery, automatic defrost, and quick-change specimen holders significantly improve laboratory efficiency while ensuring high-quality tissue sections for pathology and histological analysis.

     

    Features
    •   Dual-purpose design for frozen sections and paraffin sections.
    •  Combines a computerized precision microtome with an intelligent rapid freezing system.
    •   Intelligent LCD display for intuitive operation and real-time status monitoring.
    •   Displays preset temperature and actual operating temperature.
    • Automatic temperature control with intelligent constant-temperature regulation.
    •   Automatic alarm and automatic defrost functions.
    •   Rapid cold-stage defrost allows quick tissue replacement.
    •   Refrigeration automatically resumes after defrosting.
    •   High-precision stepper motor ensures smooth and accurate sectioning.
    •   Patented trimming adjustment allows thickness setting via control panel or fine handwheel.
    •  Quick-change specimen holder for easy switching between frozen and paraffin applications.
    •   Excellent section quality suitable for routine and intraoperative pathology.

     

    Working Principle
    The HH-3658C combines precision mechanical sectioning with rapid cryogenic cooling. For frozen section applications, the intelligent refrigeration system rapidly cools the specimen and knife to the required cutting temperature while maintaining stable thermal conditions throughout the procedure.
    The computerized microtome uses a precision stepper motor to accurately control specimen feed and section thickness. Users can perform routine sectioning or trimming using either the electronic control panel or the fine adjustment handwheel. Automatic defrost and rapid refrigeration recovery reduce downtime, enabling continuous, efficient tissue processing.

     

    Technical Specifications
    Parameter Specification
    Model HH-3658C
    Product Type Computerized Cryostat & Paraffin Microtome
    Section Thickness Range 0–100 μm
    Trimming Thickness Range 0.25–100 μm (Panel); Fine Handwheel Adjustable
    Minimum Increment 0.25 μm
    Thickness Adjustment 0–1 μm (0.25 μm steps); 1–5 μm (0.5 μm steps); 5–10 μm (1 μm steps); 10–20 μm (2 μm steps); 20–100 μm (5 μm steps)
    Sectioning Accuracy ±10%
    Specimen Retraction 20 μm
    Horizontal Specimen Travel ≥15 mm
    Vertical Specimen Travel 70 mm
    Maximum Section Size 45 × 40 mm
    Cold Stage Area 45 × 40 mm
    Maximum Cold Stage Temperature Difference ≥60°C
    Maximum Knife Temperature Difference ≥50°C
    Defrost Recovery Automatic Refrigeration Restart
    Cooling Recovery Time 4–7 Minutes
    Rapid Cold Stage Defrost 3–5 Minutes
    Display Intelligent LCD
    Drive System High-Precision Stepper Motor
    Power Supply AC 220V, 50Hz
     

    Typical Applications
    The HH-3658C is widely used in:
    •   Clinical pathology laboratories
    •   Histology laboratories
    •   Hospital pathology departments
    •   Frozen section diagnosis
    •   Routine paraffin tissue sectioning
    •   Cancer pathology
    •   Biomedical research
    •   Medical universities
    •   Pharmaceutical research laboratories
    •   Veterinary pathology laboratories
    •   Tissue engineering research

     

    HH-3658C vs Conventional Microtomes
    Feature HH-3658C Conventional Microtome
    Frozen Sectioning ✔ Integrated External Cryostat Required
    Paraffin Sectioning ✔ ✔
    Dual-Purpose Design ✔ One Instrument Separate Instruments
    LCD Intelligent Control ✔ Basic Controls
    Stepper Motor Drive ✔ High Precision Mechanical Feed
    Automatic Defrost ✔ Manual
    Temperature Monitoring Real-Time Limited
    Specimen Holder Quick-Change Design Standard
    Thickness Adjustment Electronic + Handwheel Mechanical Only
    Laboratory Efficiency High Moderate
     

    Frequently Asked Questions (FAQ)
    1. What is the HH-3658C used for?
    The HH-3658C is designed for both rapid frozen tissue sectioning and routine paraffin tissue sectioning in pathology, histology, and biomedical laboratories.
    2. Can one instrument perform both frozen and paraffin sectioning?
    Yes. The HH-3658C combines a computerized microtome with a rapid freezing system, allowing quick switching between frozen and paraffin applications.
    3. What is the section thickness range?
    The instrument supports section thicknesses from 0 to 100 μm, with a minimum adjustment increment of 0.25 μm for high-precision cutting.
    4. How quickly does the cooling system recover after defrosting?
    After automatic defrost, refrigeration resumes automatically and typically reaches the required cutting temperature within 4–7 minutes.
    5. Does the instrument include automatic defrost?
    Yes. The intelligent cooling system features automatic defrost, and the cold stage can complete rapid defrosting in approximately 3–5 minutes.
    6. What is the advantage of the stepper motor drive?
    The precision stepper motor provides accurate specimen feed, stable section thickness, smooth operation, and improved section quality compared with conventional mechanical systems.
    7. Is the trimming thickness adjustable?
    Yes. Trimming thickness can be adjusted electronically from the control panel or manually using the precision handwheel, offering excellent flexibility during specimen preparation.
    8. Which laboratories commonly use the HH-3658C?
    The system is widely used in hospitals, pathology laboratories, medical schools, research institutes, pharmaceutical laboratories, and veterinary diagnostic centers.
    9. What are the main advantages of the HH-3658C over conventional microtomes?
    The HH-3658C integrates frozen and paraffin sectioning, intelligent temperature management, automatic defrost, computerized thickness control, and rapid specimen exchange into one compact, highly efficient instrument.

     

    Why Choose the HH-3658C Computerized Cryostat & Paraffin Microtome?
    The HH-3658C Computerized Cryostat & Paraffin Microtome combines precision tissue sectioning, intelligent refrigeration, and automated temperature control in one versatile platform. Its dual-purpose capability, rapid cooling, high-precision stepper motor, patented trimming adjustment, and user-friendly LCD interface make it an ideal solution for pathology laboratories requiring efficient, accurate, and reliable frozen and paraffin tissue sectioning.

     

     
     
  • Frequently Asked Questions (FAQ)
    1. What is the HH-3658C used for?
    The HH-3658C is designed for both rapid frozen tissue sectioning and routine paraffin tissue sectioning in pathology, histology, and biomedical laboratories.
    2. Can one instrument perform both frozen and paraffin sectioning?
    Yes. The HH-3658C combines a computerized microtome with a rapid freezing system, allowing quick switching between frozen and paraffin applications.
    3. What is the section thickness range?
    The instrument supports section thicknesses from 0 to 100 μm, with a minimum adjustment increment of 0.25 μm for high-precision cutting.
    4. How quickly does the cooling system recover after defrosting?
    After automatic defrost, refrigeration resumes automatically and typically reaches the required cutting temperature within 4–7 minutes.
    5. Does the instrument include automatic defrost?
    Yes. The intelligent cooling system features automatic defrost, and the cold stage can complete rapid defrosting in approximately 3–5 minutes.
    6. What is the advantage of the stepper motor drive?
    The precision stepper motor provides accurate specimen feed, stable section thickness, smooth operation, and improved section quality compared with conventional mechanical systems.
    7. Is the trimming thickness adjustable?
    Yes. Trimming thickness can be adjusted electronically from the control panel or manually using the precision handwheel, offering excellent flexibility during specimen preparation.
    8. Which laboratories commonly use the HH-3658C?
    The system is widely used in hospitals, pathology laboratories, medical schools, research institutes, pharmaceutical laboratories, and veterinary diagnostic centers.
    9. What are the main advantages of the HH-3658C over conventional microtomes?
    The HH-3658C integrates frozen and paraffin sectioning, intelligent temperature management, automatic defrost, computerized thickness control, and rapid specimen exchange into one compact, highly efficient instrument.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com