Position: Home > > Life science instrument and equipment > Animal experimental apparatus > Animal monitor > GT6800-12 multi - parameter monitor

GT6800-12 multi - parameter monitor

Product ID:SHDWjh012

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Brand NameBJHYSDKJ
    Payment TermsT/T, paypal
    Model NumberGT6800-12
    Brief introduction:
    The multi-parameter monitor adopts imported original TFT high-brightness real color LCD screen with clear and intuitive interface, small volume and light weight.
    For adult and children are applicable, can be continuously at the same time for the patient electrocardiogram (ecg) and heart rate, noninvasive blood pressure (systolic pressure, diastolic pressure and mean arterial pressure), blood oxygen saturation, breathing, monitoring of vital signs parameters such as temperature, with screen display of ecg waveform, blood oxygen waveform, breathing waveform, blood pressure measurement, oxygen measurement data, heart rate, breathing rate, body temperature and other kinds of parameters, for ecg and blood oxygen waveform can realize waveform data playback, also has the function of displaying tables and graphics trend CO2 at the end of the function.
    Performance features:
    1. The monitor adopts the world famous brand module.
    High precision.
    The parameters are accurate.
    Reliable quality and stable performance
    2. High brightness and resolution 12.1 inch color TFT LCD display.
    The data waveform is clear and easy to see
    3. Operation mode of rotating shuttle.
    Bilingual operation interface in Chinese and English.
    Easy to learn.
    Easy to use, easy to operate
    4. Full-lead seven-channel synchronous display of ecg
    5. Five-minute playback of ecg waveform and automatic ST segment detection
    6. Time trend data memory and dynamic waveform capture
    7. The upper and lower limits of alarm can be set at will, and the automatic acoustooptic dual alarm can be set
    8. Applicable to adults, children and newborns
    9. Anti-defibrillation and anti-interference of high-frequency electrotome
    10. Remote wired central monitoring network interface
    11. Optional plug-in lithium battery.
    Alternating current and direct current 2
    12. The built-in two-channel thermal array recorder can be optional to print waveforms and charts in real time
    13. It is widely used in internal medicine, surgery, operating room, obstetrics and gynecology, pediatrics, emergency center, ICU and CCU
    14. Printer (optional) : two-channel thermal array recorder.
    Printing: real - time or event trigger recording waveform, text.
    Note: name, gender, date (year/month/day)/time (24 hours)
    15. Power supply: single external ac power supply 220V, 50Hz, maximum current 1A.
    Built-in battery: fully sealed and no maintenance for large capacity lithium battery.
    Power consumption: not greater than 70VA.
    Safety standards: comply with iec6060601-1, UL2601 medical international safety standards
    16. Function of CO2 at the end of breath
    Technical parameters (eight parameters) :
    1. ECG/ ECG
    Lead: lead all, , , , aVF, aVR, aVL, V1-6 lead thoracic display
    ST segment detection: measurement range (-2.0mV ~ +2.0mV)
    2, heart rate,
    Adult: 15-300bpm (fight/score)
    Newborns/children: 15-350 BPM (stroke/point)
    Alarm mode: acoustooptic alarm
    3. RESP/ respiration
    Respiratory measurement range:
    Adult: 7 ~ 120BrPM (times/points)
    Children and newborns: 7 ~ 150 BrPM(second/point)
    Alarm preset range: alarm over preset value
    The upper limit is 10 to 100 times/min
    The lower limit is adjustable from 0 to 99 times/min
    4. NIBP/ blood pressure
    Technology: oscillography (pulse wave oscillation)
    Working mode: manual/automatic
    Measurement unit: mmHg/Kpa
    Overpressure protection: double safety protection
    5. SPO2/ oxygen saturation
    Range: 70 ~ 100%
    Alarm preset range and error :(alarm over preset value)
    Upper limit 20% ~ 100%
    Lower limit 10% ~ 99%
    6, pulse
    20 ~ 300 times/min
    Alarm mode: acoustooptic alarm
    7. TEMP/ body temperature
    Technology: high sensitive thermistor probe
    Temperature measurement range: 0 ~ 45
    8. Exhaled CO2
    The side-flow optical sensor (inlet) is placed in the monitoring instrument, and the gas sampling tube extracts the patient's respiratory gas into the monitor in real time for concentration analysis.
    The air - water separator removes moisture from the breathing gas.
    Always check whether the gas and water separator is blocked, otherwise the moisture and dirt in the gas will affect the accuracy of measurement and increase the working noise.

Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com