Position: Home > > Environmental monitoring and analysis > Gaseous pollutants > Air detector > GH-6032 fixed pollution source integrated sampler for Industrial furnace

GH-6032 fixed pollution source integrated sampler for Industrial furnace

Product ID:HQWRkq033

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberGH-6032
    Brand NameJINSHIDA
    Payment TermsT/T, paypal
    GH-6032 fixed pollution source integrated sampler
     
    Introduction:
    The GH-6032 fixed pollution source integrated sampler is a new generation of intelligent type carefully developed by our company’s R&D personnel in accordance with the national verification regulations JJG680-2007 "Smoke Sampler Verification Regulations" HJT47-1999 "Technical Conditions of Smoke Sampler" and other standards The fixed pollution source integrated sampler can measure flue working conditions, such as flow rate, flue temperature and other parameters, and can perform three modes of flue and dust isokinetic tracking, gas sampling and isokinetic gas sampling. Scope of application: determination of smoke and dust emission concentration, converted concentration and emission rate of various boilers and industrial furnaces; various exhaust parameters of flue (dynamic pressure, static pressure, flue gas temperature, flow velocity, moisture content, flue gas flow, Standard dry flow) measurement; determination of the emission concentration and total emission of hydrogen chloride, sulfuric acid mist, hydrogen fluoride, hydrogen bromide, and chromic acid mist from various boilers, industrial furnaces and other fixed pollution sources;
    Features:
    1. All interfaces of the instrument are arranged on the slopes on both sides of the upper shell of the instrument, which is easy to operate and has strong visibility;
    2. The buttons adopt embedded modules, which are convenient for maintenance, clear writing, waterproof and dustproof, wear-resistant and anti-aging;
    3. Adopt 7.0-inch wide-temperature multi-angle flip color touch screen, with touch screen, buttons, APP, network multi-screen collaborative operation function;
    4. Working environment temperature (-20~50);
    5. The LCD screen can freely rotate back and forth from 0 to 135 degrees;
    6. Adopting DC brushless double-chamber large-flow sampling pump and electronic flowmeter, quick response and high tracking efficiency;
    7. The host is equipped with a 100cm³ (gas) 320cm³ (dust) square air chamber and a large visualized filter element, which can effectively filter water and dust and is easy to replace. Built-in double drain pumps realize the automatic discharge function of condensate during the sampling process of flue gas and dust, ensuring the instrument Long-term maintenance-free and trouble-free operation;
    8. The host integrates differential pressure and micro-pressure sensors, microprocessors, and DC rotary vane pumps. Based on the principle of pitot tube parallel method isokinetic sampling, it automatically measures and tracks the flue gas flow rate and collects soot at the same speed;
    9. The temperature sensor and pressure sensor are integrated in the host to measure and calculate parameters such as dynamic pressure, static pressure, total pressure, flue gas flow rate, moisture content, and flue gas emission volume, and automatically track flue gas flow rate and constant velocity sampling;
    10. Imported SMD components are selected, with high reliability, extremely low failure rate, greatly reduced instrument volume, and convenient carrying;
    11. Optional oxygen sensor can be used to calculate the converted concentration;
    12. Millions of sampled data are automatically selected and stored for query and printing, with a large amount of information;
    13. Sample power-off memory function, automatically continue the last sample when the call comes;
    14. Automatically memorize the monitoring target working condition parameters input last time, and sample directly next time;
    15. Parameter software calibration, you can calibrate various parameters measured by the instrument through the keyboard;
    16. Optional print item function, a wide range of smoke and smoke monitoring data, users can choose the data to be printed according to their needs;
  • Introduction:
    The GH-6032 fixed pollution source integrated sampler is a new generation of intelligent type carefully developed by our company’s R&D personnel in accordance with the national verification regulations JJG680-2007 "Smoke Sampler Verification Regulations" HJT47-1999 "Technical Conditions of Smoke Sampler" and other standards The fixed pollution source integrated sampler can measure flue working conditions, such as flow rate, flue temperature and other parameters, and can perform three modes of flue and dust isokinetic tracking, gas sampling and isokinetic gas sampling. Scope of application: determination of smoke and dust emission concentration, converted concentration and emission rate of various boilers and industrial furnaces; various exhaust parameters of flue (dynamic pressure, static pressure, flue gas temperature, flow velocity, moisture content, flue gas flow, Standard dry flow) measurement; determination of the emission concentration and total emission of hydrogen chloride, sulfuric acid mist, hydrogen fluoride, hydrogen bromide, and chromic acid mist from various boilers, industrial furnaces and other fixed pollution sources;
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com