Position: Home > > Analytical instruments > Chromatogram > Gas chromatography > GC8100 Gas Chromatograph

GC8100 Gas Chromatograph

Product ID:FSqi041

Price: Please inquire PDF Format
Supply Ability:10SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberGC8100
    Brand NameBEIJINGPULAIXI
    Payment TermsT/T, paypal
    GC8100 Gas Chromatograph
    Feature
    1. Adopt 320 x 240 dot matrix 5.1 inch large screen LCD Chinese display, real-time display of temperature and operating conditions of each channel, perfect online monitoring;
    2. Power-on self-test, six-way independent temperature control (vaporization chamber, capillary vaporization chamber can be independently controlled temperature), fifth-order program temperature heating function;
    3. Wide-range self-diagnosis function, when the instrument fails, the automatic Chinese display fault phenomenon, fault code, fault reason, help find the fault and solve the fault quickly, and ensure the best working state of the laboratory;
    4. Over-temperature protection and expansion function: If any channel exceeds the set temperature, the instrument will automatically power off and alarm;
    5. Carrier gas shut-off and gas leakage protection function, when the carrier gas pressure is insufficient, the instrument automatically cuts off the power supply and stops heating, effectively protecting the column and the thermal conductivity detector from damage;
    6. Intelligent fuzzy control to open the door system, automatically track the temperature and dynamically adjust the damper angle, even in the vicinity of room temperature can achieve precise temperature control;
    7. Configure packed column head injection, glass liner injection, capillary splitting splitless sample introduction device with diaphragm cleaning function, and gas injector can be installed;
    8. High-precision double stable gas path, up to four detectors can be installed at the same time;
    9. Advanced gas path process for simultaneous use of hydrogen flame detector and thermal conductivity monitor;
    10. Eight-way external event function supports multi-valve switching;
    Technical Parameters
    GC8100 temperature control index
    1, temperature control range: room temperature +5 ° C -400 ° C increment 0.1 ° C
    2, temperature control accuracy: better than ± 0.1 ° Cve
    3, programming temperature: the fifth-order step constant temperature O~999min increment 0.1min temperature increment 0.1 °C heating rate: 200 °C below Zui large 40 °C / min 200 °C above zui large 20 °C / min
     
    GC8100 Specifications
    1. Dimensions: 555 x 525 x 485 (mm)
    2. Input power: AC220V±7%50Hz 2KW
    3. Machine weight: about 52kg

  • Feature
    1. Adopt 320 x 240 dot matrix 5.1 inch large screen LCD Chinese display, real-time display of temperature and operating conditions of each channel, perfect online monitoring;
    2. Power-on self-test, six-way independent temperature control (vaporization chamber, capillary vaporization chamber can be independently controlled temperature), fifth-order program temperature heating function;
    3. Wide-range self-diagnosis function, when the instrument fails, the automatic Chinese display fault phenomenon, fault code, fault reason, help find the fault and solve the fault quickly, and ensure the best working state of the laboratory;
    4. Over-temperature protection and expansion function: If any channel exceeds the set temperature, the instrument will automatically power off and alarm;
    5. Carrier gas shut-off and gas leakage protection function, when the carrier gas pressure is insufficient, the instrument automatically cuts off the power supply and stops heating, effectively protecting the column and the thermal conductivity detector from damage;
    6. Intelligent fuzzy control to open the door system, automatically track the temperature and dynamically adjust the damper angle, even in the vicinity of room temperature can achieve precise temperature control;
    7. Configure packed column head injection, glass liner injection, capillary splitting splitless sample introduction device with diaphragm cleaning function, and gas injector can be installed;
    8. High-precision double stable gas path, up to four detectors can be installed at the same time;
    9. Advanced gas path process for simultaneous use of hydrogen flame detector and thermal conductivity monitor;
    10. Eight-way external event function supports multi-valve switching;
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com