Position: Home > > Analytical instruments > Chromatography Equipment > Gas chromatography > GC-2011 gas chromatograph

GC-2011 gas chromatograph

Product ID:FSqi059

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberGC-2011
    Brand NameSDJINPU
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    GC-2011 gas chromatograph 
    Introduction:
    GC-2011 is a multi-functional gas chromatograph with a packed column inlet and a capillary inlet, and the detector is single FID or TCD, which is cost-effective.
    Features:
    1. Chinese large-screen LCD display, rich and intuitive display content, and convenient setting parameters.
    2. A microcomputer automatic ignition device is adopted.
    3. Stable and reliable digital zero adjustment is adopted to avoid baseline instability caused by potentiometer zero adjustment.
    4. It has five-stage temperature programming function.
    5. The intelligent rear door automatic cooling system with frequency conversion function has a fast cooling speed and realizes near room temperature operation in the true sense.
    6. The tracking temperature rise method adopted in the column chamber avoids the contamination of the detector caused by the rapid temperature rise of the column chamber.
    7. Single-column, double-gas path structure, basically configured as FID or TCD detector.
    8. At the same time, it is equipped with a packed column vaporization chamber and an independent capillary system. It has a capillary split/non-split sampler and tail blowing system with excellent performance. It can easily install small-diameter capillary columns, large-diameter capillary columns and various packed columns.
    9. It has power-down protection function and can automatically memorize the set parameters. It has anti-power sudden interference function and stopwatch timing function.
    10. With over-temperature protection function, it will automatically cut off power and give an alarm when the temperature exceeds the set upper limit. If the temperature of any channel exceeds the set temperature, it will automatically stop heating; There are Chinese prompts of fault causes and alarm prompts.
    11. It has gas cut-off/gas leakage protection and Chinese prompt functions, which can protect TCD tungsten wire and chromatographic column from damage to the greatest extent.
    12. It has a fault self-diagnosis function, which can display Chinese fault causes and alarm prompts at any time.
    Technical parameters:
    Temperature control technical parameters:
    Temperature control range: room temperature + 8 ℃-420 ℃, temperature control objects: column box, detector, thermal conductivity cell, sampler
    Temperature control accuracy: ± 0. 1 ℃ within 200 ℃; ± 0.2 °C above 200 °C
    Temperature program: fifth-order linear lift
    Lift rate: 1-30 ℃/min, 0.1 ℃ increment
    Technical parameters of gas chromatograph detector:
    Detector Sensitivity/sensitivity Noise Drift linear peculiarity
    FID Mf ≤ 2 × 10 − 11 g/s (benzene) ≤ 5 × 10-13A ≤ 5 × 10-12A/30min ≥107 Platinum ignition wire, corundum porcelain nozzle
    TCD S ≥ 3000 mV.ml/mg (benzene) ≤ 0.02 mV ≤ 0.1 mV/h ≥105 Imported rhenium tungsten wire, constant current power supply
    Note: External dimensions: 540 * 470 * 460mm, whole machine weight: 50kg, input power supply: AC 220V ± 10% 50HZ 2KW
     
     
     
  • Introduction:
    GC-2011 is a multi-functional gas chromatograph with a packed column inlet and a capillary inlet, and the detector is single FID or TCD, which is cost-effective.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com