| Parameter | Specification |
| Model | FE-2100H |
| Applicable Standard | GB/T 3217-2013 test method |
| Materials | Ferrite, AlNiCo, NdFeB, SmCo, rare-earth permanent magnets |
| Sample Shapes | Cylindrical, rectangular, ring-shaped, arc-shaped |
| Measured Parameters | Br, Hcb, Hcj, BHmax |
| Measurement Curves | B-H and J-H hysteresis loops, demagnetization curves, temperature curves |
| Temperature Measurement | Room temperature to 200°C (optional configuration) |
| Measurement Automation | Automatic magnetic field and flux range setting, excitation control, data acquisition, and correction |
| Optional Pole Pieces | Flat, tapered, heating, and arc-shaped types |
| Optional Coils | Multiple fixed B/J coil configurations |
| Parameter | Specification |
| Display | 4½-digit LED display |
| Automatic Ranges | 2.5 / 5.0 / 10 / 20 mWb |
| Analog Output | 0 to ±5 V for each range |
| Analog Output Error | ±0.5% |
| Resolution | 1 µWb |
| Range Selection | Automatically calculated according to material type and sample geometry |
| Drift | 1 µWb/min |
| Drift Adjustment | Manual |
| Input Impedance | 10 kΩ |
| Parameter | Specification |
| Display | 4½-digit LED display |
| Automatic Ranges | 0.5 / 1 / 1.5 / 3.0 T or 0.5 / 1.0 / 2.0 / 4.0 T |
| Analog Output | 0 to ±5 V for each range |
| Analog Output Error | 0.5% |
| Resolution | 1 mT |
| Linearity | Better than ±0.2% (computer corrected) |
| Hall Element Temperature Coefficient | 0.06%/°C |
| Hall Probe | Imported Hall chip |
| Linear Correction Range | 0–2.5 T |
| Software Calibration | Better than 0.3% |
| Probe Positioning | Vertical and horizontal movement designed to maintain Hall element level |
| Parameter | Specification |
| Display | 4½-digit LED display |
| Automatic Ranges | 2.5 / 5.0 / 10 / 20 mWb |
| Analog Output | 0 to ±5 V for each range |
| Analog Output Error | ±0.5% |
| Resolution | 1 µWb |
| Range Selection | Automatically calculated according to material type and sample geometry |
| Drift | 1 µWb/min |
| Drift Adjustment | Manual |
| Input Impedance | 10 kΩ |
| Parameter | Specification |
| Signal Acquisition | Separate A/D sampling of Gaussmeter and fluxmeter analog B and H outputs |
| Excitation Control | Software control of excitation waveform, voltage amplitude, and excitation direction |
| Resolution and Linearity | 16-bit ±½ LSB |
| Sampling Frequency | 110 kHz |
| Excitation and Measurement Time | 30–120 seconds, user-selectable |
| B/H Conversion Time | Less than 25 µs |
| Synchronization | Synchronization influence considered negligible; Ba and Ha determined by software |
| Parameter | Specification |
| Input | 220 V / 5 A |
| Output Power | 400 VA |
| Control Temperature Range | 50–220°C |
| Heating Rod | 100 W per rod |
| Test Probe | Not specified |
| Temperature Uncertainty | ±2°C |
| Temperature Resolution | 1°C |
| Configuration | Non-standard accessories and components require customization |
| Comparison Item | Standard Configuration | High-Coercivity Configuration |
| Main Instruments | FE-210H Gaussmeter + FE-210B2 fluxmeter | Gaussmeter + B2 fluxmeter + additional B1 fluxmeter |
| Measurement Method | Standard magnetic field and flux measurement | Dual-integration measurement |
| Typical Application | General permanent magnet materials | Certain high-coercivity rare-earth magnets |
| Measurement Capability | Br, Hcb, Hcj, BHmax, subject to configuration | Supports measurement requirements that cannot be met by the standard configuration |
| System Configuration | Relatively simple | Additional fluxmeter required |