F030 Plate Corrosion Test Electrolytic Cell
Product Introduction
The F030 Plate Corrosion Test Electrolytic Cell is a specialized electrochemical corrosion testing cell designed for laboratory plate corrosion experiments. Its flat corrosion testing pool provides a suitable configuration for corrosion evaluation, while the double water bath supports temperature-controlled testing.
The F030 electrolytic cell is equipped with a silver chloride reference electrode and a 20 × 20 platinum mesh counter electrode. A thermometer is supported for temperature monitoring during experiments. The F030 is the double-water-bath version, while the F029 is the corresponding version without a water bath.
| Parameter | Specification |
| Product Name | F030 Plate Corrosion Test Electrolytic Cell |
| Model | F030 |
| Cell Type | Flat corrosion testing pool |
| Application | Plate corrosion testing |
| Water Bath | Double water bath |
| Temperature Control | Supported |
| Thermometer | Supported |
| Reference Electrode | Silver chloride electrode |
| Counter Electrode | Platinum mesh electrode |
| Counter Electrode Size | 20 × 20 |
| Alternative Model | F029, without water bath |
| Feature | F030 Plate Corrosion Test Electrolytic Cell | F029 Plate Corrosion Test Electrolytic Cell |
| Cell Type | Flat corrosion testing pool | Flat corrosion testing pool |
| Water Bath | Double water bath | Without water bath |
| Temperature Control | Supported | No water bath |
| Thermometer Support | Yes | Not specified |
| Reference Electrode | Silver chloride electrode | Not specified |
| Counter Electrode | 20 × 20 platinum mesh | Not specified |
| Best For | Temperature-controlled plate corrosion testing | Plate corrosion testing without a water bath |
Frequently Asked Questions (FAQ)
1. What is the F030 electrolytic cell used for?
The F030 is used for plate corrosion testing and laboratory electrochemical corrosion research.
2. What is the difference between F030 and F029?
The F030 includes a double water bath, while the F029 does not include a water bath.
3. Does the F030 support temperature-controlled testing?
Yes. The F030 is equipped with a double water bath for temperature-controlled corrosion experiments.
4. What reference electrode is used with the F030?
The supplied configuration uses a silver chloride electrode as the reference electrode.
5. What is the counter electrode specification?
The auxiliary (counter) electrode is a 20 × 20 platinum mesh electrode.
6. Is a thermometer supported?
Yes. The F030 supports a thermometer for temperature monitoring during testing.
7. What type of corrosion testing pool does the F030 use?
The F030 uses a flat corrosion testing pool, designed for plate corrosion experiments.
8. Can the F030 be used for temperature-controlled corrosion research?
Yes. Its double water bath makes it suitable for corrosion experiments where temperature control is required.

Frequently Asked Questions (FAQ)
1. What is the F030 electrolytic cell used for?
The F030 is used for plate corrosion testing and laboratory electrochemical corrosion research.
2. What is the difference between F030 and F029?
The F030 includes a double water bath, while the F029 does not include a water bath.
3. Does the F030 support temperature-controlled testing?
Yes. The F030 is equipped with a double water bath for temperature-controlled corrosion experiments.
4. What reference electrode is used with the F030?
The supplied configuration uses a silver chloride electrode as the reference electrode.
5. What is the counter electrode specification?
The auxiliary (counter) electrode is a 20 × 20 platinum mesh electrode.
6. Is a thermometer supported?
Yes. The F030 supports a thermometer for temperature monitoring during testing.
7. What type of corrosion testing pool does the F030 use?
The F030 uses a flat corrosion testing pool, designed for plate corrosion experiments.
8. Can the F030 be used for temperature-controlled corrosion research?
Yes. Its double water bath makes it suitable for corrosion experiments where temperature control is required.