Position: Home > > Analytical instruments > Spectroscopy Equipment > Infrared spectrum > EMF-70V Vacuum Fourier Transform Infrared Spectrometer

EMF-70V Vacuum Fourier Transform Infrared Spectrometer

Product ID:FGhw048

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberEMF-70V
    Brand NameHENGCHUANGLIDA
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    EMF-70V Vacuum Fourier Transform Infrared Spectrometer
    Product Introduction
    The EMF-70V Vacuum Fourier Transform Infrared Spectrometer is a high-resolution vacuum FTIR spectrometer designed for demanding infrared spectroscopy applications. Its optical and sample compartments are sealed within a vacuum system, achieving a vacuum level better than 0.2 mbar and an overall vacuum level better than 3 mbar during testing.
    The vacuum optical path helps reduce interference from atmospheric moisture and carbon dioxide, improving spectral stability and measurement reliability. With a resolution better than 0.16 cm¹, up to six built-in detectors, and extensive sampling accessories, the EMF-70V is suitable for advanced chemical analysis, materials research, and specialized infrared spectroscopy.

     

    Performance Features
      Vacuum-sealed optical and sample compartments for improved spectral stability.
      High resolution: Better than 0.16 cm¹.
      Excellent wavenumber accuracy: ≤0.005 cm¹ at 1554 cm¹.
      High signal-to-noise ratio: Better than 60,000:1 under specified conditions.
      Up to six built-in detectors, including DLaTGS, InGaAs, Si, GaP, and MCT options.
      Wear-free, high-stability interferometer with a collimated optical design.
     Pre-collimated, high-energy mid/far-infrared source with hot-swappable replacement.
      Automatic accessory recognition for convenient sampling configuration.
      Ethernet networking for remote control, data acquisition, processing, and real-time data sharing.
      Integrated IVU verification system with self-check routines and GLP-compliant reports.
      Comprehensive FTIR software for spectral processing, quantitative analysis, peak fitting, atmospheric compensation, and macro programming.

     

    Working Principle
    The EMF-70V operates using Fourier transform infrared spectroscopy. A high-energy infrared source emits radiation through the interferometer, which modulates the infrared beam to produce an interferogram. The beam then passes through the sample, where specific molecular vibrations absorb infrared energy.
    The detector records the resulting interferogram, and the software applies a Fourier transform to convert it into an infrared spectrum. The spectrum provides information about molecular structure, chemical composition, and material properties.
    The vacuum-sealed optical path minimizes atmospheric absorption from water vapor and CO, while the high-resolution optical system and interchangeable detectors support precise spectral measurements across a broad infrared range.

     

    Technical Parameters
    Parameter Specification
    Model EMF-70V
    Spectral Range 8,000–350 cm¹; optional 28,000–10 cm¹
    Resolution Better than 0.16 cm¹
    EMF-70V vs. Conventional FTIR Spectrometers
    Feature EMF-70V Vacuum FTIR Conventional Non-Vacuum FTIR
    Optical Path Vacuum-sealed Usually air-filled
    Atmospheric Interference Reduced water vapor and CO absorption More susceptible to atmospheric interference
    Resolution Better than 0.16 cm¹ Depends on model; often lower
    Wavenumber Accuracy ≤0.005 cm¹ at 1554 cm¹ Depends on model
    Detectors Up to 6 built-in detectors Usually fewer built-in detector options
    Accessory Compatibility Wide range of vacuum and commercial accessories Depends on instrument configuration
    Networking Ethernet remote control and real-time data sharing Depends on model
    Verification Integrated IVU self-check with GLP reports Depends on model
    Best Suited For High-resolution research and demanding infrared analysis Routine FTIR testing and general laboratory analysis

    Frequently Asked Questions (FAQ)
    1.  What is the EMF-70V vacuum FTIR spectrometer used for?
     It is used for high-resolution infrared spectroscopy, molecular identification, chemical analysis, materials research, and specialized vacuum-based FTIR applications.
    2. What is the spectral range of the EMF-70V?
    The standard range is 8,000–350 cm¹, with an optional extended range of 28,000–10 cm¹.
    3. What is the resolution of this vacuum Fourier transform infrared spectrometer?
    The EMF-70V provides a resolution better than 0.16 cm¹.
    4. Why is a vacuum optical path important in FTIR?
    Vacuum sealing reduces atmospheric water vapor and CO absorption, helping improve spectral stability and reduce interference during measurements.
    5. How many detectors can the EMF-70V accommodate?
     It can include up to six built-in detectors, including DLaTGS, InGaAs, Si, GaP, and MCT options.
    6. Can the EMF-70V connect to an infrared microscope or Raman system?
     Yes. The instrument supports integration with infrared microscopes, Raman systems, thermal analysis accessories, and a wide range of sampling accessories.
    7. Does the EMF-70V support remote operation?
    Yes. Ethernet networking enables remote control, data acquisition, data processing, and real-time data sharing.
    8. What software is included with the EMF-70V?
     The software package includes FTIR control, spectral processing, data conversion, multicomponent quantification, peak fitting, HO/CO compensation, self-check, macro programming, and online help.
    9. Can the EMF-70V be used for GLP-compliant laboratory verification?
    Yes. Its built-in IVU verification system uses standard reference materials and provides self-check reports suitable for GLP-oriented laboratory workflows.
     

     
  • Frequently Asked Questions (FAQ)
    1.  What is the EMF-70V vacuum FTIR spectrometer used for?
     It is used for high-resolution infrared spectroscopy, molecular identification, chemical analysis, materials research, and specialized vacuum-based FTIR applications.
    2. What is the spectral range of the EMF-70V?
    The standard range is 8,000–350 cm¹, with an optional extended range of 28,000–10 cm¹.
    3. What is the resolution of this vacuum Fourier transform infrared spectrometer?
    The EMF-70V provides a resolution better than 0.16 cm¹.
    4. Why is a vacuum optical path important in FTIR?
    Vacuum sealing reduces atmospheric water vapor and CO absorption, helping improve spectral stability and reduce interference during measurements.
    5. How many detectors can the EMF-70V accommodate?
     It can include up to six built-in detectors, including DLaTGS, InGaAs, Si, GaP, and MCT options.
    6. Can the EMF-70V connect to an infrared microscope or Raman system?
     Yes. The instrument supports integration with infrared microscopes, Raman systems, thermal analysis accessories, and a wide range of sampling accessories.
    7. Does the EMF-70V support remote operation?
    Yes. Ethernet networking enables remote control, data acquisition, data processing, and real-time data sharing.
    8. What software is included with the EMF-70V?
     The software package includes FTIR control, spectral processing, data conversion, multicomponent quantification, peak fitting, HO/CO compensation, self-check, macro programming, and online help.
    9. Can the EMF-70V be used for GLP-compliant laboratory verification?
    Yes. Its built-in IVU verification system uses standard reference materials and provides self-check reports suitable for GLP-oriented laboratory workflows.
     

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com