EFCM-100 Ammonia Nitrogen Rapid Tester

Product ID:HSYAad041

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberEFCM-100
    Brand NameHFENFAN
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    EFCM-100 Ammonia Nitrogen Rapid Tester
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

    Product Overview
    The EFCM-100 Ammonia Nitrogen Rapid Tester is a high-performance water quality analysis instrument developed using advanced international technology. Equipped with a high-performance imported light source and optimized optical measurement system, it delivers accurate, stable, and reliable ammonia nitrogen measurements while effectively minimizing interference from stray light.
    The instrument features an 8-inch color touchscreen with a fully Chinese-language interface, providing intuitive operation and convenient data management. With built-in data storage, waterproof design, USB and RJ45 communication interfaces, and a thermal printer, it is suitable for routine water quality testing in laboratories, wastewater treatment facilities, universities, and research institutions.
    The EFCM-100 is designed for ammonia nitrogen determination in surface water, groundwater, domestic sewage, industrial wastewater, and drinking water.
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

    Key Features
    • High Measurement Accuracy: Provides measurement accuracy and repeatability of ≤ ±3% for reliable analytical results.
    • Advanced Optical System: Uses a high-performance imported light source to improve measurement stability and reduce stray light interference.
    • Wide Measurement Range: Measures ammonia nitrogen concentrations from 0.00 to 100.00 mg/L, with diluted sample testing available for higher concentrations.
    • High-Resolution Detection: Offers a resolution of 0.001 mg/L for detecting small concentration differences.
    • Intuitive Touchscreen Operation: Features an 8-inch color LCD touchscreen with a fully Chinese-language interface.
    • Convenient Data Management: Supports data storage, USB flash drive data transfer, and RJ45 network connectivity.
    • Built-in Thermal Printing: Allows test results to be printed directly for convenient documentation and reporting.
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

    Working Principle
    The EFCM-100 Ammonia Nitrogen Rapid Tester uses a colorimetric measurement method to determine ammonia nitrogen concentrations in water samples.
    During testing, the prepared sample is placed in a colorimetric tube and reacted with the appropriate chemical reagents to produce a color corresponding to the ammonia nitrogen concentration. The instrument's optical system uses an imported light source to illuminate the sample and detect the resulting optical signal.
    The instrument analyzes the measured signal and calculates the ammonia nitrogen concentration based on the established calibration relationship. Its optimized optical system helps minimize stray light interference, improving measurement accuracy, repeatability, and stability.
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

    Technical Specifications
    Parameter Specification
    Model EFCM-100
    Measurement Parameter Ammonia Nitrogen (NH₃-N)
    Measurement Range 0.00–100.00 mg/L
    Extended Measurement Higher concentrations can be measured after sample dilution
    Measurement Accuracy ≤ ±3%
    Repeatability ≤ ±3%
    Resolution 0.001 mg/L
    Light Source Lifetime More than 150,000 hours
    Wavelength Accuracy Central wavelength ±1 nm
    Optical Stability ≤ 0.001 A / 10 min
    Display 8-inch color LCD touchscreen
    Interface Language Chinese
    Detection Method Colorimetric tube
    Data Storage Supported
    Communication Interfaces USB and RJ45 Ethernet
    Data Transfer Direct communication and data download via USB flash drive
    Printing Method Thermal printer
    Power Supply 220 V AC
    Dimensions 400 × 245 × 157 mm
    Weight 4 kg
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

    Applications
    The EFCM-100 Ammonia Nitrogen Rapid Tester is suitable for routine water quality monitoring and laboratory analysis across multiple industries.
    • Environmental Monitoring: Ammonia nitrogen testing in surface water, rivers, lakes, and groundwater.
    • Wastewater Treatment: Monitoring ammonia nitrogen levels in domestic sewage and industrial wastewater treatment processes.
    • Drinking Water Analysis: Ammonia nitrogen determination during drinking water quality inspection.
    • Industrial Laboratories: Routine water quality testing in manufacturing and industrial facilities.
    • Universities and Research Institutions: Laboratory experiments, environmental research, and water chemistry analysis.
    • Water Quality Inspection: Supporting water quality assessment and environmental compliance monitoring.
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

    Applicable Standards
    The EFCM-100 is designed for ammonia nitrogen determination in various water matrices, including surface water, groundwater, domestic sewage, industrial wastewater, and drinking water.
    Specific compliance with national or international analytical standards should be confirmed with the manufacturer according to the selected reagent system and testing procedure.
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

    Comparison
    The EFCM-100 can be compared with other common ammonia nitrogen testing technologies based on their measurement principles and operating characteristics.
    Comparison Parameter EFCM-100 Rapid Tester Traditional Colorimetric Testing Laboratory Spectrophotometer
    Measurement Principle Instrument-based colorimetry Visual or manual colorimetry Spectrophotometry
    Result Reading Automatic Usually manual Automatic
    Display 8-inch touchscreen Visual comparison or basic display Depends on model
    Data Storage Supported Usually manual recording Model dependent
    Data Export USB and RJ45 Usually manual Model dependent
    Printing Built-in thermal printer Usually unavailable Model dependent
    Typical Application Routine ammonia nitrogen testing Basic water testing Laboratory quantitative analysis
    The EFCM-100 integrates optical measurement, touchscreen operation, data management, and printing in one instrument, making it suitable for laboratories and water treatment facilities requiring convenient routine ammonia nitrogen analysis.
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━

    Frequently Asked Questions (FAQ)
    1. What parameter does the EFCM-100 measure?
    The EFCM-100 is designed specifically for ammonia nitrogen (NH₃-N) measurement in water samples.
    2. What is the measurement range of the EFCM-100?
    Its standard measurement range is 0.00–100.00 mg/L. Samples exceeding this range can be tested after appropriate dilution.
    3. What is the measurement accuracy?
    The specified measurement accuracy is ≤ ±3%, with repeatability also specified at ≤ ±3%.
    4. What types of water samples can be tested?
    It is suitable for surface water, groundwater, domestic sewage, industrial wastewater, and drinking water samples.
    5. How does the instrument measure ammonia nitrogen?
    It uses a colorimetric method. The prepared sample is placed in a colorimetric tube, and the optical system measures the color response to determine ammonia nitrogen concentration.
    6. Can test results be exported to a computer?
    Yes. The instrument provides USB and RJ45 Ethernet interfaces and supports direct data downloading through a USB flash drive.
    7. Does the EFCM-100 support printing test results?
    Yes. It is equipped with a thermal printer for convenient on-site printing of measurement results.
    8. What should buyers consider before purchasing this instrument?
    Buyers should confirm the required ammonia nitrogen measurement range, sample types, testing frequency, reagent requirements, data management needs, and applicable analytical standards. They should also confirm whether the instrument's language interface meets their operational requirements.
    ━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━
     

     
  • Frequently Asked Questions (FAQ)
    1. What parameter does the EFCM-100 measure?
    The EFCM-100 is designed specifically for ammonia nitrogen (NH₃-N) measurement in water samples.
    2. What is the measurement range of the EFCM-100?
    Its standard measurement range is 0.00–100.00 mg/L. Samples exceeding this range can be tested after appropriate dilution.
    3. What is the measurement accuracy?
    The specified measurement accuracy is ≤ ±3%, with repeatability also specified at ≤ ±3%.
    4. What types of water samples can be tested?
    It is suitable for surface water, groundwater, domestic sewage, industrial wastewater, and drinking water samples.
    5. How does the instrument measure ammonia nitrogen?
    It uses a colorimetric method. The prepared sample is placed in a colorimetric tube, and the optical system measures the color response to determine ammonia nitrogen concentration.
    6. Can test results be exported to a computer?
    Yes. The instrument provides USB and RJ45 Ethernet interfaces and supports direct data downloading through a USB flash drive.
    7. Does the EFCM-100 support printing test results?
    Yes. It is equipped with a thermal printer for convenient on-site printing of measurement results.
    8. What should buyers consider before purchasing this instrument?
    Buyers should confirm the required ammonia nitrogen measurement range, sample types, testing frequency, reagent requirements, data management needs, and applicable analytical standards. They should also confirm whether the instrument's language interface meets their operational requirements.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com