Position: Home > > Life science instrument and equipment > Clinical test instrument and equipment > Other clinical tests > ECG-11D digital single channel electrocardiograph for Clinical monitoring

ECG-11D digital single channel electrocardiograph for Clinical monitoring

Product ID:SHLCqt027

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberECG-11D
    Brand NameKEMEISI
    Payment TermsT/T,paypal
    Specifications Paper size
    Dimension: 292mm×228mm×70mm 50mm*20m (30m), roll type
    Weight: 3.3Kg
    Print out format
    Display 1, 2 channel rhythm lead
    2“ 192 x 64 ” graphic LCD
    Specifications
    Lead Standard or Cabrera 12 leads,
    Isolated input circuit Miscellaneous Input Circuit
    Protection against defibrillation and pace making Patient Cable DJ ECG-A.F01.001A
    Calibration Voltage 1mV±5% LCD Display Operation status; Heart-rate; ECG waveform
    Sampling Rate 1ms Safety Level Class I, Type CF
    A/D conversion 12 bit Power Requirements AC: 220V(110V), 50~60Hz; 30VA
    Battery: Sealed rechargeable battery, 14.4V, 1.2Ah AUTO1: Standard automatic single channel Operation Mode
    AUTO2: European automatic single channel Fuse Specification AC time lag: T125mA/250V(220V)
    AUTO3: Simulating three channel T250mA/1
    AUTO4: Rhythm lead + standard lead DC time lag: T2A/250V 1-Ф 5×20mm
    MAN: Manual lead change
    Lead Duration Automatically increase lead duration in AUTO1~AUTO3 Environmental Conditions
    Filter AC 50Hz(-20dB) , EMG 35Hz(-3dB) Transportation: Temperature: -40℃~+55 EXT&CRO
    CMRR > 100dB Relative Humidity: 25%95% EXT Single ended
    Input Circuit Current 50nA Atmospheric Pressure: 700hPa1060hPa Input Impedance:100KΩ
    Input Impedance >50MΩ Storage: Temperature: -10℃~+40 Sensitivity:10mm/mV±5%
    Patient Leakage Current <10μA Relative Humidity: 25%80% Input Voltage:±2.5V
    Time Constant 3.2s Atmospheric Pressure: 700hPa1060hPa Single ended
    Frequency Response 0.05~150Hz Operation: Temperature: +5℃+40℃ CRO Output Impedance:≤100Ω
    Noise Level <15μVp-p Relative Humidity: 25%80% Sensitivity:0.5V/Mv±5%
    Threshold ≤20μV Atmospheric Pressure: 700hPa1060hPa
    Sensitivity 5,10,20mm/mV Recorder
    Skin Voltage Tolerance ±400mV Printer Thermal array printer: 8dot/mm(Vertical),
    Baseline Control Automatic baseline control 40dot/mm(Horizontal, 25mm/S)
    Automatic inhibition of baseline drift Print Out Sensitivity, paper speed, filter operation, time, heart rate,lead mark
     
    Papar speed 25,50mm/S
                           
     
     
  • All kinds of professional and technical personnel owned by the company account for 70% of the total number of employees, and their majors involve biomedical engineering, electronics, machinery, algorithms and data structures, automatic control, embedded systems, instrumentation, etc. With more than 20 years of professional experience, he has long been committed to the research and development, manufacturing, marketing and service of medical electronic equipment such as electrocardiographs, monitors, and dynamic electrocardiogram analysis systems.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com