Position: Home > > Industry specific instrument > Special instrument for detection of hazardous chemicals > Special instrument for detection of dangerous gases > ECB-2002A Multi-Phase High Temperature High Pressure Explosion Limit Tester

ECB-2002A Multi-Phase High Temperature High Pressure Explosion Limit Tester

Product ID:HZWHwxqt006

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberECB-2002A
    Brand NameHZYANGYI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ECB-2002A Multi-Phase High Temperature High Pressure Explosion Limit Tester
    Product Introduction
    The ECB-2002A Multi-Phase High Temperature High Pressure Explosion Limit Tester is an advanced explosion characteristics testing instrument developed based on EN 1839, ASTM E918, ASTM E2079, EN 15967, and UL9540A standards.
    The system is designed to evaluate critical combustion and explosion characteristics under controlled temperature and pressure conditions, including explosion limits, limiting oxygen concentration (LOC), explosion pressure, and pressure rise rate.
    With modular hardware, programmable experimental procedures, automatic gas preparation, vacuum cleaning, mixing, temperature control, and comprehensive safety protection, the ECB-2002A provides a flexible solution for laboratory research and industrial explosion safety evaluation.

     

    Reference Standards
    •  EN 1839
    •  ASTM E918
    •  ASTM E2079
    •  EN 15967
    •  UL9540A
    Performance Features
    •  Modular testing architecture for flexible configuration according to different •  explosion testing requirements.
    •  Programmable test procedures allow users to edit and customize experimental processes.
    •  316L stainless steel test vessel provides excellent corrosion resistance and durability.
    •  Jacket temperature control enables efficient and stable thermal regulation.
    •  Flexible constant-temperature settings balance testing efficiency and measurement accuracy.
    •  High-efficiency vacuum pump with programmable cleaning parameters helps minimize residual gas effects.
    •  Precision gas measurement and control with compensation algorithms for accurate gas concentration preparation.
    •  Integrated stirring system ensures uniform mixing of multi-component gas samples.
    •  Dedicated explosion pressure sensor provides high-temperature resistance and fast dynamic response.
    •  Automated gas handling including vacuum evacuation, gas dosing, and mixing.
    •  Multiple safety protection systems including safety interlocks, safety valves, and rupture discs.
    •  High-speed pressure acquisition captures rapid explosion pressure changes for accurate analysis.

     

    Working Principle
    The ECB-2002A explosion limit tester prepares a controlled gas or multi-phase sample by automatically evacuating the test vessel and introducing the required gases through its precision gas control system.
    The gas mixture is then stirred to achieve uniform concentration. The test vessel is maintained at the preset temperature using a jacket temperature-control system. After the specified test conditions are established, the sample is ignited according to the selected experimental procedure.
    The dedicated high-speed explosion pressure sensor continuously detects pressure changes generated during combustion. The data acquisition system records the explosion pressure and pressure-time curve at a sampling frequency of at least 5 kHz.
    By changing gas composition, oxygen concentration, temperature, or other test conditions, researchers can determine explosion limits, limiting oxygen concentration, maximum explosion pressure, and pressure rise characteristics.

     

    Technical Parameters
    Parameter Specification
    Product Name ECB-2002A Multi-Phase High Temperature High Pressure Explosion Limit Tester
    Working Environment -5 to 45℃, <95% RH
    Test Vessel Temperature Range Room temperature to 200℃
    Gas Configuration Pressure Up to 1 atm, ±0.1% FS
    Test Vessel Design Pressure ≥2.0 MPa
    Explosion Pressure Sensor ≥5.0 MPa
    Pressure Sensor Linearity ±1.0% FS
    Pressure Acquisition Frequency ≥5 kHz
    Data Points per Test ≥10,000
    Gas Input Channels 3 channels
    Maximum Stirrer Speed 400 rpm
    Stirring Speed Adjustable
    Test Vessel Material 316L stainless steel
    Temperature Control Jacket temperature control
    Gas Preparation Automatic gas dosing and concentration compensation
    Vacuum System Automatic evacuation and programmable cleaning
    Safety Protection Interlock, safety valve, rupture disc
     

    Application Scenarios
    Explosion Limit and Flammability Research
    Determines the explosion limits and combustion characteristics of combustible gases and multi-component mixtures.
    Limiting Oxygen Concentration Testing
    Used to evaluate the minimum oxygen concentration required to sustain an explosion and support inerting and explosion prevention studies.
    High-Temperature Explosion Research
    Provides controlled temperature conditions up to 200℃ for studying the influence of temperature on explosion characteristics.
    Energy Storage and Battery Safety Research
    The UL9540A-compatible testing concept makes the system suitable for relevant thermal runaway and fire/explosion safety research involving energy storage systems.
    Chemical and Process Safety
    Used in chemical laboratories, process safety research, combustible gas evaluation, and industrial explosion risk assessment.
    Scientific Research and Material Safety
    Suitable for universities, research institutes, and industrial laboratories investigating gas combustion and explosion mechanisms.

     

    ECB-2002A vs Conventional Explosion Testing Equipment
    Feature ECB-2002A Conventional Explosion Tester
    Temperature Testing Up to 200℃ Often limited
    Gas Preparation Automatic multi-channel dosing More manual operation
    Gas Input Channels 3 Usually fewer
    Gas Mixing Integrated adjustable stirring Basic or manual mixing
    Vacuum Cleaning Automatic and programmable Manual or limited
    Pressure Acquisition ≥5 kHz high-speed acquisition Lower acquisition capability
    Test Vessel 316L stainless steel Material varies
    Test Procedure Flexible programmable workflows Fixed or semi-manual procedures
    Safety System Interlock + safety valve + rupture disc Basic protection
    Explosion Characteristics Explosion limit, LOC, pressure and pressure rise Often limited parameters
     

    Frequently Asked Questions (FAQ)
    1. What can the ECB-2002A Explosion Limit Tester measure?
    It can measure explosion limits, limiting oxygen concentration, explosion pressure, and pressure rise rate under controlled test conditions.
    2. What standards does the ECB-2002A support?
    The system is developed based on EN 1839, ASTM E918, ASTM E2079, EN 15967, and UL9540A testing requirements.
    3. What is the maximum test temperature?
    The test vessel temperature can be controlled from room temperature up to 200℃.
    4. What is the pressure rating of the test vessel?
    The test vessel has a design pressure of at least 2.0 MPa, while the explosion pressure sensor has a measurement capacity of at least 5.0 MPa.
    5. How many gas input channels are available?
    The ECB-2002A provides three gas input channels for controlled gas preparation.
    6. Does the system automatically prepare the gas mixture?
    Yes. It can automatically evacuate the vessel, introduce gases, compensate gas concentration, and mix the gases to improve sample uniformity.
    7. How fast does the pressure acquisition system operate?
    The explosion pressure acquisition system has a sampling frequency of at least 5 kHz and can collect at least 10,000 data points in a single experiment.
    8. What safety protections are included?
    The system incorporates safety interlocks, safety valves, and rupture discs to provide multiple layers of protection during explosion testing.
    9. What is the maximum stirring speed?
    The integrated stirrer provides an adjustable maximum speed of 400 rpm.

     
     
  • Frequently Asked Questions (FAQ)
    1. What can the ECB-2002A Explosion Limit Tester measure?
    It can measure explosion limits, limiting oxygen concentration, explosion pressure, and pressure rise rate under controlled test conditions.
    2. What standards does the ECB-2002A support?
    The system is developed based on EN 1839, ASTM E918, ASTM E2079, EN 15967, and UL9540A testing requirements.
    3. What is the maximum test temperature?
    The test vessel temperature can be controlled from room temperature up to 200℃.
    4. What is the pressure rating of the test vessel?
    The test vessel has a design pressure of at least 2.0 MPa, while the explosion pressure sensor has a measurement capacity of at least 5.0 MPa.
    5. How many gas input channels are available?
    The ECB-2002A provides three gas input channels for controlled gas preparation.
    6. Does the system automatically prepare the gas mixture?
    Yes. It can automatically evacuate the vessel, introduce gases, compensate gas concentration, and mix the gases to improve sample uniformity.
    7. How fast does the pressure acquisition system operate?
    The explosion pressure acquisition system has a sampling frequency of at least 5 kHz and can collect at least 10,000 data points in a single experiment.
    8. What safety protections are included?
    The system incorporates safety interlocks, safety valves, and rupture discs to provide multiple layers of protection during explosion testing.
    9. What is the maximum stirring speed?
    The integrated stirrer provides an adjustable maximum speed of 400 rpm.
     

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com