Position: Home > > Lab general equipment > Sample preparation and digestion > Electric heating digestion > DTI-60T Automatic Graphite Digestion System

DTI-60T Automatic Graphite Digestion System

Product ID:SYZYXJdrxj036

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberDTI-60T
    Brand NameDINGTAIHENGSHENG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    DTI-60T Automatic Graphite Digestion System
    Product Introduction

    The DTI-60T Automatic Graphite Digestion System is an advanced laboratory sample preparation instrument designed for high-throughput inorganic element analysis pretreatment. It integrates electric heating digestion, automatic reagent addition, non-contact mechanical mixing, liquid level sensing, robotic lifting, cooling, and intelligent PC control into a complete automated digestion workflow.
    The DTI-60T automatically completes key digestion procedures including reagent adding, sample mixing, heating digestion, acid evaporation, cooling, and volume adjustment. It significantly improves laboratory efficiency, reduces manual operation errors, and ensures consistent digestion results.
    The system adopts a fully enclosed PTFE corrosion-resistant structure and complies with EPA, national, and industry-standard digestion requirements. It is widely used for soil, plant, food, and other sample preparation before inorganic element analysis.

     
    Performance Features
    Fully Automated Digestion Process
    • One-stop automation of:
    Acid addition.
    Sample mixing.
    Heating digestion.
    Acid removal.
    Cooling.
    Volume adjustment.
    • Reduces manual operation and improves laboratory efficiency.
    Excellent Corrosion Resistance
    • Fully enclosed PTFE structure.
    • No exposed transmission belts.
    • Long-term resistance to acid vapor corrosion.
    • Suitable for harsh chemical digestion environments.
    Precise Temperature and Volume Control
    • Dual graphite heating blocks with independent temperature control.
    • Dual-arm support structure maintains stable ultrasonic sensor positioning.
    • Accurate liquid level sensing and automatic volume adjustment.
    Intelligent Control System
    • Touchscreen computer, desktop computer, and laptop wireless control.
    • Real-time experiment progress display.
    • Audio alerts for completion and reagent shortage.
    • Flash memory recovery after unexpected power failure.
    • Can continue digestion offline without controller connection.
    Flexible Reagent Addition
    • Optional combination of peristaltic pump and syringe pump.
    • Two pump systems complement each other for accurate and efficient reagent delivery.

     
    Working Principle
    The DTI-60T Automatic Graphite Digestion System uses controlled graphite heating technology combined with automated liquid handling and intelligent monitoring.
    During operation:
    1.Samples are placed into digestion vessels.
    2.The automatic reagent system precisely adds acids according to the programmed method.
    3.Non-contact mechanical mixing ensures uniform sample and reagent reaction.
    4.Dual graphite heating modules provide accurate and independent temperature control.
    5.Digestion proceeds under controlled heating conditions.
    6.The system performs acid removal, cooling, and automatic volume adjustment.
    7.The digested solution is ready for inorganic element analysis using techniques such as ICP-OES, ICP-MS, or AAS.
    This automated workflow improves digestion consistency and reduces operator influence on analytical results.

     
    Technical Parameters
    Parameter Specification
    Model DTI-60T Automatic Graphite Digestion System
    Digestion Capacity 50mL × 60 positions
    Application Simple samples, soil, plants, unprocessed food, similar matrix samples
    Digestion Method Electric graphite heating digestion
    Sample Processing Fully automatic digestion workflow
    Heating System Dual graphite blocks with independent control
    Reagent Addition Optional peristaltic pump + syringe pump
    Control Method Touchscreen computer / PC / wireless laptop control
    Structure Material Fully enclosed PTFE corrosion-resistant design
    Liquid Level Control Ultrasonic sensing and automatic volume adjustment
    Mixing Method Non-contact mechanical oscillation
    Data Recovery Flash memory breakpoint recovery
    Operation Mode Online intelligent control or offline operation
    Applicable Standards EPA, national standards, industry standards
     
    Application Scenarios
    1. Soil Element Analysis
    Used for automated digestion of soil samples before heavy metal and inorganic element analysis.
    2. Plant Sample Testing
    Suitable for plant tissues and agricultural sample digestion for mineral element determination.
    3. Food Safety Analysis
    Used for batch digestion of unprocessed food samples before elemental testing.
    4. Environmental Monitoring
    Provides reliable sample preparation for environmental laboratories analyzing inorganic pollutants.
    5. Research Laboratories
    Ideal for universities and scientific research institutions requiring automated digestion workflows.

     
    DTI-60T Automatic Graphite Digestion System vs Traditional Manual Digestion
    Feature DTI-60T Automatic Graphite Digestion System Traditional Manual Digestion
    Operation Mode Fully automated Manual operation
    Sample Throughput 60 samples simultaneously Limited batch capacity
    Reagent Addition Automatic precision dispensing Manual addition
    Temperature Control Independent dual graphite heating Less precise
    Digestion Consistency High repeatability Operator dependent
    Acid Vapor Protection Fully enclosed PTFE structure Higher exposure risk
    Data Recovery Automatic breakpoint recovery Usually unavailable
    Workflow Efficiency One-stop automated process Multiple manual steps
     
    FAQ
    1. What is the DTI-60T Automatic Graphite Digestion System used for?
    The DTI-60T is used for automated digestion and preparation of samples before inorganic element analysis.
    2. How many samples can the DTI-60T process?
    The system can process 60 samples simultaneously using 50mL digestion vessels.
    3. What samples are suitable for the DTI-60T?
    It is suitable for soil, plant materials, unprocessed food samples, and other similar matrix samples.
    4. What are the advantages of graphite digestion?
    Graphite heating provides uniform temperature distribution, precise control, and excellent chemical resistance compared with traditional heating methods.
    5. Can the instrument recover after power failure?
    Yes. The built-in flash memory function allows the system to resume digestion from the interruption point.
    6. Can the DTI-60T operate without a computer controller?
    Yes. The system can continue digestion offline after being disconnected from the external controller.
    7. Which analytical instruments can use the digested samples?
    The prepared samples can be used for inorganic element analysis instruments such as ICP-OES, ICP-MS, and AAS.

     
    Conclusion
    The DTI-60T Automatic Graphite Digestion System is an intelligent high-throughput graphite digestion instrument designed for efficient and reliable laboratory sample preparation. With automated reagent addition, precise dual-temperature control, corrosion-resistant PTFE construction, and intelligent operation management, it provides an advanced solution for soil, plant, food, environmental, and inorganic element analysis laboratories.

     

     


  • FAQ
    1. What is the DTI-60T Automatic Graphite Digestion System used for?
    The DTI-60T is used for automated digestion and preparation of samples before inorganic element analysis.
    2. How many samples can the DTI-60T process?
    The system can process 60 samples simultaneously using 50mL digestion vessels.
    3. What samples are suitable for the DTI-60T?
    It is suitable for soil, plant materials, unprocessed food samples, and other similar matrix samples.
    4. What are the advantages of graphite digestion?
    Graphite heating provides uniform temperature distribution, precise control, and excellent chemical resistance compared with traditional heating methods.
    5. Can the instrument recover after power failure?
    Yes. The built-in flash memory function allows the system to resume digestion from the interruption point.
    6. Can the DTI-60T operate without a computer controller?
    Yes. The system can continue digestion offline after being disconnected from the external controller.
    7. Which analytical instruments can use the digested samples?
    The prepared samples can be used for inorganic element analysis instruments such as ICP-OES, ICP-MS, and AAS.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com