Position: Home > > Environmental monitoring and analysis > Water quality on-line detection > Water quality on-line monitoring system > DR-103E Water Quality Online Automatic Monitoring Quality Control Instrument

DR-103E Water Quality Online Automatic Monitoring Quality Control Instrument

Product ID:HSZXzdjc034

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberDR-103E
    Brand NameDERUNHUANBAO
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    DR-103E Water Quality Online Automatic Monitoring Quality Control Instrument
     
    Product Introduction
    The DR-103E Water Quality Online Automatic Monitoring Quality Control Instrument is designed for automatic quality assurance and performance verification of online water quality analyzers. It can be remotely controlled to supply standard solutions with known concentrations or spiked water samples to online monitoring instruments. By comparing analyzer results with known reference values, the system helps evaluate instrument operating conditions and verify the reliability of monitoring data.
    Featuring a compact modular design, the DR-103E supports distributed installation close to online analyzers, reducing sample transmission distances and minimizing pipeline-related measurement errors. One display controller can manage multiple quality control terminals through RS-485 cascading communication, with each terminal corresponding to an online monitoring analyzer.
    The system supports manual and automatic operation, scheduled and periodic quality control, remote data management, intelligent fault detection, and alarm functions. It provides a flexible and cost-effective solution for environmental monitoring stations, wastewater treatment facilities, industrial wastewater monitoring, and environmental regulatory applications.

     


    Performance Features
    1.  Flexible Operating Modes: Supports both manual and automatic operation to accommodate different water quality monitoring and quality assurance requirements.
    2. Multiple Quality Control Modes: Provides immediate, scheduled, and periodic quality control functions for flexible verification of online monitoring instruments.
    3. Remote Management: Supports remote quality control result queries, categorized statistical analysis, automatic data quality reports, and personnel permission management.
    4.  Internal and External Quality Control: Supports both internal and external quality control modes to meet different monitoring and verification requirements.
    5. Modular System Architecture: One display controller can manage multiple quality control terminals, with each terminal serving one online monitoring analyzer. Additional measurement parameters can be supported by adding corresponding terminals.
    6. Distributed Installation: Compact quality control terminals can be installed close to online analyzers, reducing sample transmission distances and minimizing installation space. The local installation footprint is less than 0.1 m³.
    7. Intelligent Idle-Time Quality Control: Automatically identifies analyzer idle periods and performs quality control operations when appropriate, helping reduce interference with routine measurements.
    8. Automatic Self-Diagnosis and Alarms: Detects faults such as missing or expired standard solutions and low standard solution levels. Automatically generates alarms when quality control results exceed preset limits.
    9. Secure Access Management: Equipped with electronic access control and password-based authorization to improve equipment security and operational management.
    10. Automatic Clock Calibration: Supports immediate clock synchronization and scheduled daily automatic calibration, with adjustable synchronization times.
    11. Power Failure Data Protection: Retains quality control records during unexpected power failures and uploads power interruption information to the remote management platform.
    12. Multiple Communication Options: Supports wired and wireless communication between local and remote control systems, as well as communication with other control systems.

     


    Working Principle
    The DR-103E operates by automatically supplying standard solutions with known concentrations or spiked water samples to online water quality analyzers for performance verification.
    Its working process consists of the following steps:
    1. Quality Control Configuration: Users configure immediate, scheduled, or periodic quality control tasks through the local controller or remote management platform.
    2. Standard Sample Supply: The system automatically delivers a specified volume of standard solution or spiked water sample to the corresponding online analyzer.
    3.  Automatic Sample Analysis: The online monitoring instrument analyzes the supplied sample and returns its measurement results.
    4. Result Comparison: The quality control system compares the measured results with the known reference concentrations to evaluate analyzer performance and data reliability.
    5. Data Recording and Reporting: Quality control results are automatically stored and transmitted to the remote management platform for statistical analysis and reporting.
    6. Fault Detection and Alarms: The system performs self-diagnosis, monitors standard solution status, and generates alarms when abnormalities or excessive measurement deviations are detected.
    Its modular architecture allows multiple quality control terminals to operate under a centralized display controller, supporting scalable quality assurance across multiple online monitoring instruments.

     


    Technical Parameters
    Parameter Specification
    Single Standard Solution Delivery Volume 150 mL
    Number of Standard Solutions 3
    Volume per Standard Solution Concentration 1 L
    Sample Transmission Error ±1.5%
    Refrigerator Temperature 4°C ±2°C
    Data Storage Capacity 30,000 records
    Number of Cascaded Quality Control Terminals 1–16 (expandable)
    Data Acquisition Error ≤1‰
    Clock Error ±0.5‰
    Communication Interfaces RS-485 / RS-232
    Insulation Resistance ≥20 MΩ
    Operating Humidity ≤85% RH
    Operating Temperature 5–40°C
    Rated Voltage AC 220 V ±22 V
    Rated Frequency 50 Hz ±0.5 Hz
    Display Controller Dimensions 320 × 120 × 300 mm
    Quality Control Terminal Dimensions 460 × 180 × 660 mm
     


    Application Scenarios
    • Environmental Monitoring Stations: Verifying the performance and data reliability of online water quality monitoring instruments.
    •  Wastewater Treatment Plants: Performing automatic quality control of water quality analyzers at treatment plant inlets and outlets.
    • Industrial Wastewater Monitoring: Supporting reliable monitoring data verification in chemical, pharmaceutical, petrochemical, and manufacturing facilities.
    •   Surface Water Monitoring: Maintaining the reliability of automated monitoring systems used for rivers, lakes, and other water bodies.
    •  Environmental Regulatory Applications: Providing environmental authorities with remote quality control, data verification, and monitoring equipment supervision.
    •  Multi-Parameter Monitoring Networks: Managing multiple online analyzers through a centralized controller and expandable quality control terminals.

     


    Comparison: DR-103E vs. Conventional Water Quality Quality Control Systems
    Feature DR-103E Quality Control Instrument Conventional Quality Control System
    Operating Modes Manual and automatic Depends on configuration
    Quality Control Methods Immediate, scheduled, periodic May be limited
    Sample Supply Standard solutions and spiked samples Depends on system
    Installation Compact distributed installation May require centralized installation
    Analyzer Management Multiple terminals under one controller Depends on configuration
    Expansion 1–16 terminals, expandable Depends on system architecture
    Remote Management Queries, statistics, and automatic reports Depends on configuration
    Idle-Time Quality Control Intelligent analyzer idle-time identification Not always available
    Fault Detection Automatic self-diagnosis and alarms Depends on configuration
    Data Storage 30,000 records Varies by model
    Power Failure Protection Data retention and remote notification Depends on configuration
     


    Frequently Asked Questions (FAQ)
    Q1: What is the DR-103E water quality quality control instrument used for?
    The DR-103E is used to verify the performance and data reliability of online water quality monitoring instruments by supplying standard solutions or spiked water samples and comparing measured results with known reference values.
    Q2: What quality control modes does the DR-103E support?
    It supports three quality control modes: immediate quality control, scheduled quality control, and periodic quality control.
    Q3: Can the DR-103E be controlled remotely?
    Yes. It supports remote operation, quality control result queries, statistical analysis, automatic data quality reports, and personnel permission management through a remote control platform.
    Q4: How many online monitoring analyzers can the DR-103E manage?
    One display controller can manage 1–16 quality control terminals through RS-485 cascading communication. The system can be expanded according to monitoring requirements.
    Q5: What is the standard solution delivery volume?
    The system provides 150 mL of standard solution per delivery, with three available standard solutions and a volume of 1 L per standard solution concentration.
    Q6: Does the DR-103E support automatic fault detection?
    Yes. Its self-diagnosis function can identify missing or expired standard solutions, low solution levels, and abnormal quality control results, generating corresponding alarms.
    Q7: How much data can the DR-103E store?
    The instrument supports storage of up to 30,000 records for quality control and monitoring data management.
    Q8: Does the DR-103E retain data during power failures?
    Yes. Quality control records are retained during unexpected power interruptions, and power failure information is uploaded to the remote management platform.
    Q9: What are the installation advantages of the DR-103E?
    Its compact, distributed design allows quality control terminals to be installed close to online analyzers. This reduces sample transmission distances, minimizes pipeline-related errors, and requires less than 0.1 m³ of local installation space.


  • Frequently Asked Questions (FAQ)
    Q1: What is the DR-103E water quality quality control instrument used for?
    The DR-103E is used to verify the performance and data reliability of online water quality monitoring instruments by supplying standard solutions or spiked water samples and comparing measured results with known reference values.
    Q2: What quality control modes does the DR-103E support?
    It supports three quality control modes: immediate quality control, scheduled quality control, and periodic quality control.
    Q3: Can the DR-103E be controlled remotely?
    Yes. It supports remote operation, quality control result queries, statistical analysis, automatic data quality reports, and personnel permission management through a remote control platform.
    Q4: How many online monitoring analyzers can the DR-103E manage?
    One display controller can manage 1–16 quality control terminals through RS-485 cascading communication. The system can be expanded according to monitoring requirements.
    Q5: What is the standard solution delivery volume?
    The system provides 150 mL of standard solution per delivery, with three available standard solutions and a volume of 1 L per standard solution concentration.
    Q6: Does the DR-103E support automatic fault detection?
    Yes. Its self-diagnosis function can identify missing or expired standard solutions, low solution levels, and abnormal quality control results, generating corresponding alarms.
    Q7: How much data can the DR-103E store?
    The instrument supports storage of up to 30,000 records for quality control and monitoring data management.
    Q8: Does the DR-103E retain data during power failures?
    Yes. Quality control records are retained during unexpected power interruptions, and power failure information is uploaded to the remote management platform.
    Q9: What are the installation advantages of the DR-103E?
    Its compact, distributed design allows quality control terminals to be installed close to online analyzers. This reduces sample transmission distances, minimizes pipeline-related errors, and requires less than 0.1 m³ of local installation space.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com