DNM-9602G Automatic Microplate Reader

Product ID:SHLCmby009

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Brand NameYM
    Payment TermsT/T, paypal
    Model NumberDNM-9602G
    Instroduction
    This instrument is composed by the host and the external printer.
    Features:
    1) The instrument uses the whole English show.
    2) The instrument has a self test function
    3) Select filter method: automatically selected by the instrument.
    4) Test pattern: a single, double and single wavelength, double detection method available. 5) input and format: Input via the touch-screen operationr and lower case letters and numbers.
    6) The project parameters are set: to set, save, modify, and query parameters of 120 test items.
    7) The calibration test: a test calibration function, can save and modify the 120 project parameters and calibration curves, detection of doing the same project and can print when you can call the calibration curve.
    8) detection method: with absorbance, qualitative and quantitative analysis methods.
    9) storage test results: 105 test results can be saved for future calls.
    10) output:
    a. Absorbance detection: Instrument display and print the original absorbance detection;
    b. Qualitative analysis: Instrument display and print test absorbance values, the critical value, S / CO values, qualitative determination results;
    c. Quantitative detection: Instrument display and print test absorbance value, concentration, normal reference values to determine the results.
    11) quality control function: can query and print quality control data, you can display and print quality control chart.
    12) Communication method: RS-232 equipment with a communication port, with two transmission protocols. A protocol in which the Company's proprietary software for communication operations, and another agreement for the software developed with the user communication operation;
    13) The instrument has a light signal of each detection channel real-time automated monitoring.
    14) Light lamps have hibernation function
    Product Scope.
    The instrument and the registered supporting the use of ELISA reagents can be used for the detection of enzyme-linked immunosorbent class project
    Technical Parameter
    1) Measurement System: 8-channel detection of light;
    2) The instrument detection range :0.000-4 .000 A; resolution of 0.001A;
    3) Apparatus configured the center wavelength of interference filters accuracy ± 3.0, half-width ≤ 12;
    4) Instrument operating wavelength range 400nm-800nm, the standard instrument configuration: 405nm, 450nm, 492nm, 630nm, 400nm-800nm range in the options, configure up to 10;
    5) Absorbance accuracy: ± 0.01 (0.000-2.000); ± 0.05 (> 2.000-3.000); ± 0.15 (> 3.000-4.000);
    6) Linearity error: ± 1.0% (0.000-2.000); ± 2.0 % (> 2.000-3.000); ± 5.0% (> 3.000-4.000);
    7) Repeatability: ≤ 0.5%;
    8) Stability: ≤ ± 0.005A.
     
  • This instrument is composed by the host and the external printer.

Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com