DKF-089 Multi-function Karl Fischer Micro Moisture Analyzer Introduction: Currently, the moisture content of many samples can only be accurately tested using a heating furnace and a trace moisture analyzer. The DKF-089 multi-function Karl Fischer trace moisture analyzer heats the sample to high temperatures, vaporizing its moisture and other volatile substances. These are then carried by a carrier gas through a heated sample outlet tube and into the sample cell of the Karl Fischer moisture analyzer, where accurate measurements are taken. The heating furnace of the DKF-089 multi-function Karl Fischer trace moisture analyzer adopts a new design concept, drawing on the strengths of various instruments from both domestic and international sources. The sample heating temperature and control methods can be directly set through a 10-inch LCD touch screen. The Karl Fischer moisture analyzer allows for the direct setting of various required parameters on the page through a 7-inch LCD screen. The device incorporates many advanced technologies and processes, achieving international-level performance. It employs a physical-chemical method combined with an integrated coulometric titration principle and a unique needle design, enabling carrier gas input and water vapor output in a single operation. Due to the new gas path design, water vapor transmission can be achieved with minimal flow rate. Each sample injection only requires replacing the sample bottle, making the operation convenient without the need to wait for the sample bottle to cool before replacing the cap. It is compatible with numerous domestic and international standards and offers advantages such as high accuracy, fast electrolysis speed, short equilibration time, accurate blank subtraction, and reliable analysis results. Features: 1. Equipped with a 7-inch high-definition display screen, the interface is intuitive and elegant, with easy-to-use operations; 2. The instrument possesses functions such as storing, printing, and calculating test results; 3. Customize the heating temperature according to the requirements; 4. Optional: manual sample injection, automatic sample injection; 5. The measurement efficiency is higher and more accurate, 6. The sample outlet pipeline can be independently temperature-controlled, 7. Advanced algorithms can accurately subtract the moisture in the carrier gas and the environment, reducing sample errors. 8 formulas and 5 methods, with optional result units; 9. User-definable end point potential; 10. Multiple endpoint control methods, including drift endpoint, potential endpoint, time endpoint, etc., are available for selection, Technical Specifications: Product Name: Guanya Karl Fischer Micro Moisture Analyzer Measurement range: 3-19999.9 micrograms of water; relative moisture content: 5ppm-100% Measurement speed: 2.8mg H2O/min (maximum) Temperature control accuracy: 0.1℃ Portable stove display: 10-inch large LCD screen Operation of portable stove: touch-sensitive operation Screen parameters of portable stove: curve, heating rate, temperature resolution, time, etc Measurement accuracy: 3μg (10μg—100μg H2O) ≤0.3% (water content >100μg H2O), excluding sample injection error Resolution: 0.1μg H2O Delayed titration: 0-9999 seconds Sample methods: 5 independent methods Calculation formula: 8 built-in calculation formulas Temperature control range: (optional, customizable) room temperature to 200℃; room temperature to 300℃ (optional) Sample bottle needle insertion mode: automatic, manual (optional) Heating rate: 30℃/min (50-180℃, 220V) Flow range: 0-100ml/min (optional) Sample bottle specification: 10ml (5ml and 20ml options available) Data printing: Built-in thermal printer, related standards
DKF-089 Multi-function Karl Fischer Micro Moisture Analyzer Introduction: Currently, the moisture content of many samples can only be accurately tested using a heating furnace and a trace moisture analyzer. The DKF-089 multi-function Karl Fischer trace moisture analyzer heats the sample to high temperatures, vaporizing its moisture and other volatile substances. These are then carried by a carrier gas through a heated sample outlet tube and into the sample cell of the Karl Fischer moisture analyzer, where accurate measurements are taken. The heating furnace of the DKF-089 multi-function Karl Fischer trace moisture analyzer adopts a new design concept, drawing on the strengths of various instruments from both domestic and international sources. The sample heating temperature and control methods can be directly set through a 10-inch LCD touch screen. The Karl Fischer moisture analyzer allows for the direct setting of various required parameters on the page through a 7-inch LCD screen. The device incorporates many advanced technologies and processes, achieving international-level performance. It employs a physical-chemical method combined with an integrated coulometric titration principle and a unique needle design, enabling carrier gas input and water vapor output in a single operation. Due to the new gas path design, water vapor transmission can be achieved with minimal flow rate. Each sample injection only requires replacing the sample bottle, making the operation convenient without the need to wait for the sample bottle to cool before replacing the cap. It is compatible with numerous domestic and international standards and offers advantages such as high accuracy, fast electrolysis speed, short equilibration time, accurate blank subtraction, and reliable analysis results.