Position: Home > > Life science instrument and equipment > Molecular biology instrument > Protein chromatography purification > ClearFirst - 5000Process Type Protein Purification System

ClearFirst - 5000Process Type Protein Purification System

Product ID:SHFZdbcx009

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberClearFirst - 5000Process
    Brand NameSHSPSW
    Payment TermsT/T, paypal
    Introduction :
    ClearFirst - 5000Process type protein purification system is a key multi - channel parallel protein purification system developed by Shanghai flash spectrum biology , which is mainly used for large quantity of protein purification work in large - scale life sciences laboratories , which greatly improves the efficiency of purification work and saves a large amount of manpower and material resources compared with the traditional method .
    ClearFirst - 5000 Process - type protein purification system has unique advantages in pump , detector , fraction collector and control workstation software . It is a completely modularized product , which can separate five samples completely different . It can increase the number of channels flexibly , has extremely powerful function and extremely high cost performance , and is the ideal choice for high flux analysis and separation of protein purification laboratory in China .
    Instrument characteristics:
    1 , A high - precision constant - current pump is used to form a high - precision gradient curve , so that the generation of bubbles is avoided , and the high - precision constant - current pump has extremely high practical value ;
    2, The high - precision constant - current pump is used , the pulsation is small , the baseline is stable , the flow output is accurate , and the performance is much higher than that of the peristaltic pump system ;
    3, The flow rate is 0 - 20 ml / min , the flow rate is 0 - 40 ml / min , and the analysis and preparation can be taken into account ;
    4, Adopting a full - wavelength detector , and selecting an arbitrary wavelength between 190 - 850 nm for detection ;
    5,The full - automatic fraction collector eliminates the phenomena of pipe skip , disturbance and overflow , and has high stability ;
     
    6 ,The bottom of the X - Y matrix collecting device has no motor , and the safety is better than that of the disk type fraction collector ;
    7, Collecting the fraction by using a 24 - hole or 96 - hole deep - hole micro - hole plate to save the collection volume ;
    8, The high - precision fraction collection software ensures that the collection tube corresponds exactly to the peak position and convenient to find ;
    9 ,The three - way valve with waste liquid collection is adopted to adapt to the continuous collection of high school pressure , so that only the required components can be collected ;
    10,The peak collection judgment is accurate , omission and cross contamination are avoided , and manpower is saved ;
    11, It has many modes such as peak collection , time , level , manual collection and so on , with high flexibility ;
    12,The flow cell can adopt different optical paths to adapt to different analysis and purification requirements ;
    13, A method database is provided , and different purification methods can be preset at any time to complete automatic operation ;
    14 . A large number of special conductivity detectors with high precision and high precision are the same as those of imported products ;
    15 . The standard PH detector has the function of temperature correction , the precision is better than the imported product ;
    16 , the volume is compact , and the device is very convenient to put the equipment into a chromatographic refrigerator ;
    17, The pressure - bearing pipeline of the system is basically PEEK material , and the pressure resistance and biocompatibility are good ;
    18 ,The sampling mode of the multi - way valve is used , the sample injection is accurate , and air is prevented from entering the system ;
    19,The instrument can be fully controlled by computer , which greatly reduces the use difficulty ;
    20, Instrument self - inspection , user management and sample management can be carried out , and the information system can be connected ;
    21,Five channels can be used for parallel separation , the separation flux is large , and the method is suitable for a large quantity of samples ;
    22,The wavelength accuracy is better than 0.2 nm , and the detection sensitivity is better than that of diode array type products .
    23, All Chinese interfaces of the workstation are convenient to use and conform to the habits of Chinese people ;
    24, Only upgrade the multi - pass valve buffer expansion assembly ( 8 or 12 ) to form more types of buffers ;
    25,The instrument is completely modularized , saves space , is easy to increase and decrease , and has high flexibility ;
    26,The instrument can be equipped with a large volume injection system and a sampling pump for large volume injections ;
     
    27,The instrument can use a multi - channel chromatographic column switching system for different chromatographic column switching ;
    28,A chromatographic column with different fillers can be used for each channel , and different separation systems can be used ;
    29,Different injection rings can be used for each channel , and the sampling amount can be completely different ;
    30,Different detection wavelengths can be used for each channel to correspond to different samples ;
    Instrument Composition :
    1 . Host ( including high precision constant current pump , buffer selection valve , multi - pass sampling valve ) ;
    2 . Detector ( including full - wavelength ultraviolet detector , conductivity detector , digital - to - analog converter ) ;
    3 . Fully automatic fraction collector ;
    4 . Special workstation for purification of CStar - 5000 protein ;
    Instrument parameters :
    1 . Solvent compatibility : the aqueous buffer used for the purification of commonly used biomolecules ;
    2 . Flow rate range : 0 - 20ml / min ( optional 0 - 40ml / min ) ;
    3 . Pressure range : 0 - 0.7MPa ( 7 bar , 100 psi )
    4 . Viscosity : up to 5 cP ;
    5 . Wavelength range : 190 - 850 nm ;
    6 . Optical path length : the standard is 2mm , the rest can be customized ;
    7 . Conductivity range : 1uS / cm - 999.9mS / cm ;
    8 . PH determination range : 0 - 14.00 ;
    9 . PH determination accuracy : 0.01N unit , temperature compensation ;
    10 . Channel number : 5 channels ;
    Purpose of the instrument :
    1 . Protein purification ( gel , ion exchange , hydrophobic interaction , affinity , etc . ) ;
    2 , Separating and purifying the nucleic acid ;
    3 , Separating and purifying antibiotic polymer impurities ;
    4 , Separating and purifying the natural product ;


     
  • Introduction :
    ClearFirst - 5000Process type protein purification system is a key multi - channel parallel protein purification system developed by Shanghai flash spectrum biology , which is mainly used for large quantity of protein purification work in large - scale life sciences laboratories , which greatly improves the efficiency of purification work and saves a large amount of manpower and material resources compared with the traditional method .
    ClearFirst - 5000 Process - type protein purification system has unique advantages in pump , detector , fraction collector and control workstation software . It is a completely modularized product , which can separate five samples completely different . It can increase the number of channels flexibly , has extremely powerful function and extremely high cost performance , and is the ideal choice for high flux analysis and separation of protein purification laboratory in China .
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com