Position: Home > > Life science instrument and equipment > Microbial detection apparatus > Microbial detection system > BYW-600 microbial limit detector for Pharmaceutical, food, chemical

BYW-600 microbial limit detector for Pharmaceutical, food, chemical

Product ID:SHWSWjc035

Price: Please inquire PDF Format
Supply Ability:100 SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberBYW-600
    Brand NameSHANGHAIBINGYUE
    Payment TermsT/T, paypal
    BYW-600 microbial limit detector
    Introduction:
    The BYW-600 microbial limit detection system is made of stainless steel and is equipped with a built-in imported diaphragm liquid pump. There is no need to connect an external suction filter bottle. The liquid is directly discharged through the diaphragm liquid pump, which reduces the cumbersome use of the suction filter bottle and avoids connection It is not good to cause shortcomings such as slow suction filtration speed. working principle:
    Inject the test product into the microbial limit incubator, filter by negative pressure through the built-in imported diaphragm liquid pump of the tester, trap the microorganisms in the test product on the filter membrane, take out the filter membrane with the membrane remover, and transfer to the configured On the solid medium with the bacteria side facing up, stick flat. Cover the lid to form a closed culture box, place it in the corresponding constant temperature incubator and count.
    Application of microbial limit detector:
    Pharmaceutical: purified water, water for injection, ophthalmic preparations, raw materials, capsules, biological products, tablets, oral preparations;
    Food: purified water, mineral water, beverages;
    Chemical industry: various water samples that need to be tested for microorganisms;
    Cosmetics: various water and products;
    Disease control: rivers, rivers, lakes, seas, water samples.
    Features:
    1. The filter cup adopts a unique lip-shaped seal design, does not use clamps and O-rings, to ensure leak-free operation and uniform microbial recovery;
    2. The filter membrane is pre-sterilized, which can be used immediately after disassembly, which can reduce the source of main pollutants and improve the reliability of detection;
    3. Direct suction filtration and drainage, no need to suction filter bottle, easy to install and use;
    4. Built-in imported diaphragm liquid pump, higher efficiency;
    5. The compact body reduces the occupation of the operating table area;
    6. Waterproof switch is simple and convenient;
    7. The six-unit filter head design can draw and filter at the same time to improve work efficiency. Each filter head can also be independently controlled, which is convenient for the operator to use flexibly;
    8. The filter head can be quickly disassembled and assembled, and can be sterilized separately by damp heat;
    9. The filter head can be quickly sterilized by flame, which is convenient for continuous experiment operation;
    10. Adopt single-sided circular arc filter, easy to replace;
    11. The surface of the instrument is mirror-treated for easy cleaning and disinfection;
    12. The filter cup is designed with reusable materials, which is durable, cost-saving and easy to operate.
    Technical Parameters:
    1. Applicable membrane diameter: 47mm/50mm;
    2. Effective filter diameter: 40mm;
    3. Number of filter heads: 1-6;
    4. Detection method: membrane filtration method;
    5. Suction filtration method: negative pressure suction filtration by diaphragm pump, no need for suction bottle;
    6. Pumping rate: 100ml/15s (with membrane);
    7. Filter head sterilization method: moist heat sterilization, flame gun rapid sterilization;
    8. Size: 74*20*14cm (length*width*height);
    9. Weight: 6kg;
    10. Power: 50W;
    11. Working voltage: AC220V/50HZ;
    12. The noise is less than 30dB;
    13. Physical button switch;
    14. Three-head and six-head structure can be selected, and the selection is abundant.
  • Introduction:
    The BYW-600 microbial limit detection system is made of stainless steel and is equipped with a built-in imported diaphragm liquid pump. There is no need to connect an external suction filter bottle. The liquid is directly discharged through the diaphragm liquid pump, which reduces the cumbersome use of the suction filter bottle and avoids connection It is not good to cause shortcomings such as slow suction filtration speed. working principle:
    Inject the test product into the microbial limit incubator, filter by negative pressure through the built-in imported diaphragm liquid pump of the tester, trap the microorganisms in the test product on the filter membrane, take out the filter membrane with the membrane remover, and transfer to the configured On the solid medium with the bacteria side facing up, stick flat. Cover the lid to form a closed culture box, place it in the corresponding constant temperature incubator and count.
    Application of microbial limit detector:
    Pharmaceutical: purified water, water for injection, ophthalmic preparations, raw materials, capsules, biological products, tablets, oral preparations;
    Food: purified water, mineral water, beverages;
    Chemical industry: various water samples that need to be tested for microorganisms;
    Cosmetics: various water and products;
    Disease control: rivers, rivers, lakes, seas, water samples.
     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com