Biolot 50 protein purification system

Product ID:SHFZdbcx022

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberBiolot 50
    Brand NameSHSANWEI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    Biolot 50 protein purification system
    Introduction:
    The protein purification system is a concise and efficient protein purification system, in which the biolot50 laboratory protein purification system is applied for method exploration, process optimization, and filler screening, suitable for protein purification preparation of samples ranging from milligrams to grams. The hardware of the Biolot system consists of PEEK chromatography pump, sample loading pump, UV detector, conductivity/PH detector, automatic fraction collector, mixer, and valve. It is used in conjunction with bioview software, chromatography column, and packing, and the instrument can meet any purification challenge. The system configuration is flexible, supports various chromatography techniques, and meets the development requirements of customers for purification processes from small-scale to pilot scale.
    Can quickly separate biomolecules such as proteins and peptides
    Features:
    1. Highly flexible modular configuration makes the research process more intuitive
    2 . Adopting high-precision plunger pump, high stability, and low pulse
    3 . High sensitivity online detection, optional with various detectors such as UV, PH, conductivity, differential refractive index, etc
    4. The flow path is made of PEEK material, which has good biocompatibility
    5. The pump head has an automatic cleaning function to avoid buffer residue and crystal precipitation
    6. Fully automatic fraction collector with multiple collection modes and configurable collection tubes of various specifications
    7. Standard gradient program, customers can reset according to experimental needs
    8. Storage and execution of chromatographic separation methods
    9. Highly intelligent operating system, easy and convenient to use
    10. The control software meets the certification requirements of FDA 21 CFR Part 11
    Technical Specifications:
    Model: Biolot 50
    System pump: PEEK high-pressure chromatography pump (high precision, gradient design, biocompatibility)
    Flow rate range: 0.01-50ml/min
    Flow velocity accuracy: ± 0.5%
    Pressure range: 0-20Mpa
    Pressure pulsation: ≤ 0.2MPa
    Gradient types: step, linear gradient, gradient can be modified online
    Minimum gradient adjustment: ± 0.5% ABS (dual pump)
    Detector light source: imported deuterium lamp+tungsten lamp (system automatically switches light sources)
    Detection wavelength: 190-800nm (simultaneous detection of two wavelengths)
    Wavelength accuracy: ± 1nm
    Absorption range: -3--3AU (linear 0-2 AU)
    Conductivity range: 0-99.9ms/cm
    PH range: 0-14
    Collector: Fully automatic fraction collector
    Collection rack: 2 × 60 test tubes (height 150mm, diameter 15mm)
    Collection modes: Normal mode, Sequential collection, Loop collection
    Manual sample loading valve: comes standard with a 1ml quantitative ring (various specifications of quantitative rings can be optionally selected)
    Power supply: 85-264VAC, 50Hz
    Control software:
    A software workstation based on Windows system, with multi module system control and design that complies with FDA 21 CFR Part 11 certification. Its functions include multi-user management, instrument control, method preparation, data processing, and report printing
    Reference size: Infusion pump: 370 × 240 × 152mm3 UV detector: 370 × 240 × 152mm3
    Conductivity/PH: 370 × 240 × 100mm3 Automatic fraction collector: 355 × 241 × 320mm3

  • Introduction:
    The protein purification system is a concise and efficient protein purification system, in which the biolot50 laboratory protein purification system is applied for method exploration, process optimization, and filler screening, suitable for protein purification preparation of samples ranging from milligrams to grams. The hardware of the Biolot system consists of PEEK chromatography pump, sample loading pump, UV detector, conductivity/PH detector, automatic fraction collector, mixer, and valve. It is used in conjunction with bioview software, chromatography column, and packing, and the instrument can meet any purification challenge. The system configuration is flexible, supports various chromatography techniques, and meets the development requirements of customers for purification processes from small-scale to pilot scale.
    Can quickly separate biomolecules such as proteins and peptides
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com