Position: Home > > Lab general equipment > Fluid handling equipment > Pipetting workstation > Auto Prep 200 Automated Liquid Sample Preparation Workstation

Auto Prep 200 Automated Liquid Sample Preparation Workstation

Product ID:SYYCgzzh009

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberAuto Prep 200
    Brand NameXIAMENRUIKE
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    Auto Prep 200 Automated Liquid Sample Preparation Workstation
     
    Product Introduction
    The Auto Prep 200 Automated Liquid Sample Preparation Workstation is designed to meet the liquid preparation requirements of modern laboratories. It automates routine preparation tasks, including mixed-standard solution preparation, calibration curve preparation, sample addition, liquid dispensing, and sample dilution.
    With intelligent concentration and volume calculations, a dual-pump liquid handling system, programmable preparation methods, and real-time process monitoring, the Auto Prep 200 helps reduce manual workload and improve preparation consistency and repeatability. Its semiconductor-based temperature control system, optional light-shielding enclosure, and automated cleaning functions support the preparation of volatile, light-sensitive, and contamination-sensitive solutions.
    Designed for unattended operation, the workstation helps minimize prolonged operator contact with chemicals while improving workflow efficiency, traceability, and reproducibility in laboratory sample preparation.

     


    Performance Features
    1. Automated and Reproducible Preparation
    •  Executes liquid preparation procedures automatically according to programmed methods.
    • Standardizes preparation steps to reduce variability between batches and operators.
    •  Supports method saving and reuse for routine laboratory workflows.
    2. Intelligent Concentration and Volume Calculations
    • Automatically calculates the required transfer volumes based on stock concentration, target concentration, and target preparation volume.
    •  Supports batch editing and one-click copying of repeated parameters.
    •  Intelligently identifies excessive dilution ratios and can automatically introduce intermediate solutions for stepwise dilution.
    3. Dual-Pump Precision Liquid Handling
    •  Uses a dual-pump system to support precise liquid transfer during preparation.
    •  Automatically selects a suitable syringe for the required preparation task.
    • Provides visible tracking of liquid transfer volumes from both pumps during operation.
    4. Specialized Piercing Needle for Volatile Solvents
    •  Enables preparation using capped containers for suitable volatile solvents.
    • Transfers samples through a dedicated piercing needle, reducing solvent exposure to the surrounding environment.
    • Automatically disengages from the bottle after transfer, helping limit evaporation-related concentration changes.
    5. Semiconductor-Based Temperature Control
    • Incorporates a low-temperature control system to regulate the preparation environment.
    •  Helps reduce the effects of ambient temperature on volatile standard solutions.
    •  Supports more stable preparation conditions for temperature-sensitive liquids.
    6. Optional Light-Shielding Enclosure
    •  An optional light-shielding enclosure helps protect photosensitive compounds from light exposure during preparation.
    •  Supports improved preparation consistency for compounds that may degrade under illumination.
    7. Automated Cleaning and Cross-Contamination Control
    Customizable multistage needle cleaning
    •  Provides programmable cleaning stages for the sampling needle.
    •  Helps reduce liquid residue and carryover between samples.
    Disposable pipette-tip mode
    •  Supports automatic loading and disposal of disposable pipette tips.
    •  Reduces direct reuse of liquid-contact components and helps minimize cross-contamination risks.
    8. Intelligent Method Programming
    •  Uses a command-based method editor designed for straightforward workflow configuration.
    • Guides users through solvent settings, instrument parameters, preparation method settings, intelligent checks, and method saving.
    •  Allows saved methods to be recalled and started with one command.
    9. Real-Time Monitoring and Data Traceability
    •  Displays instrument status and preparation progress in real time.
    •  Shows the transfer volumes of the dual-pump system for convenient process monitoring.
    •  Automatically generates preparation record reports after completion to support data storage and traceability.
    10. Enclosed, Unattended Operation
    •  Supports automated preparation without continuous manual intervention.
    •  Reduces prolonged operator contact with laboratory chemicals.
    • Helps limit preparation errors caused by manual calculations, inconsistent handling, and environmental variations.

     


    Working Principle
    The Auto Prep 200 operates by combining programmable liquid handling, intelligent calculation software, and automated process control.
    Users configure the solvent settings, instrument parameters, stock solution concentration, target concentration, and required preparation volume. The software calculates the required transfer volumes and evaluates the dilution procedure. When the dilution ratio is too high for direct preparation, the system can generate an intermediate solution and perform sequential dilution.
    During operation, the dual-pump system transfers the required liquids according to the saved method. Depending on the selected configuration, the workstation can use a piercing needle for capped containers or disposable pipette tips to help reduce carryover. Programmable multistage cleaning further reduces residual liquid between preparation steps.
    The temperature control system helps maintain suitable preparation conditions, while optional light shielding protects photosensitive compounds. Real-time monitoring and automatically generated preparation records support process oversight and result traceability.

     


    Technical Parameters
    Parameter Specification
    Model Auto Prep 200
    Product Type Automated Liquid Sample Preparation Workstation
    Preparation Functions Mixed-standard preparation, calibration curve preparation, sample addition, liquid dispensing, sample dilution
    Liquid Handling System Dual-pump system
    Calculation Functions Automatic concentration and transfer-volume calculations
    Dilution Function Intelligent intermediate-solution generation for high dilution ratios
    Method Management Method editing, saving, recalling, batch editing, one-click start
    Sample Transfer Options Dedicated piercing needle; disposable pipette-tip mode
    Cleaning Function Customizable multistage automatic needle cleaning
    Temperature Control Integrated semiconductor-based low-temperature control
    Light Protection Optional light-shielding enclosure
    Process Monitoring Real-time instrument status and dual-pump volume display
    Data Recording Automatic generation of preparation record reports
    Operating Mode Programmable automated operation; supports unattended workflows
    Note: Numerical specifications such as preparation volume range, dispensing accuracy, repeatability, syringe capacity, throughput, temperature range, and workstation dimensions were not provided in the source information. Confirm these details with the manufacturer before technical comparison or procurement.
     


    Application Scenarios
    • Analytical Chemistry Laboratories: Automated preparation of standard solutions and calibration curves for quantitative analysis.
    •  Environmental Testing Laboratories: Preparation and dilution of solutions used in water, soil, and other environmental sample analysis.
    •  Pharmaceutical Laboratories: Routine preparation of analytical standards and test solutions, subject to method and material compatibility.
    • Chemical and Materials Laboratories: Controlled preparation of mixed standards, reagents, and working solutions.
    • Quality Control Laboratories: Repeatable preparation of standards and samples for routine testing and batch analysis.
    •  Research and Development: Flexible method programming for experimental liquid preparation and multistep dilution.
    •  Volatile Solvent Applications: Capped-container handling that helps reduce solvent evaporation during transfer.
    • Photosensitive Compound Preparation: Optional light shielding for compounds susceptible to light-induced degradation.

     


    Auto Prep 200 vs. Manual Liquid Sample Preparation
    Feature Auto Prep 200 Workstation Manual Preparation
    Concentration Calculations Automated calculation Usually performed by the operator
    Transfer Volume Calculation Automatic Manual calculation or separate software
    Calibration Curve Preparation Programmable and repeatable Repeated manual preparation
    Serial Dilution Can generate intermediate solutions intelligently Requires manual planning and execution
    Liquid Transfer Automated dual-pump system Manual pipetting or dispensing
    Volatile Solvent Handling Piercing needle supports capped-container transfer Depends on manual handling procedures
    Cleaning Programmable multistage cleaning Manual cleaning or rinsing
    Cross-Contamination Control Cleaning routines or disposable pipette-tip mode Depends on operator technique and consumables
    Temperature Management Integrated semiconductor-based temperature control Depends on laboratory environmental conditions
    Light Protection Optional light-shielding enclosure Requires separate protective measures
    Process Monitoring Real-time status and transfer-volume display Manual observation and recording
    Data Traceability Automatically generated preparation reports Depends on manual records or external systems
    Operator Workload Reduced routine manual intervention More hands-on preparation work
     


    Frequently Asked Questions
    1. What is the Auto Prep 200 used for?
    The Auto Prep 200 automates laboratory liquid sample preparation, including mixed-standard preparation, calibration curve preparation, sample addition, dispensing, and dilution.
    2. Can the workstation prepare calibration curves automatically?
    Yes. Users can configure stock concentrations, target concentrations, and required volumes. The software calculates the necessary transfer volumes to support programmed calibration curve preparation.
    3. How does the Auto Prep 200 handle high dilution ratios?
    Its intelligent method software can identify dilution ratios that are too high for direct preparation and automatically create an intermediate solution for stepwise dilution.
    4. How does the workstation help prevent cross-contamination?
    It offers customizable multistage cleaning for the sampling needle and a disposable pipette-tip mode with automatic tip loading and disposal. These functions help reduce carryover, although appropriate method validation and cleaning procedures remain necessary.
    5. Can it prepare volatile solvent solutions?
    The dedicated piercing needle supports transfer from capped containers, helping reduce solvent exposure and evaporation during preparation. Suitability depends on solvent compatibility, container design, and the selected method.
    6. Is temperature control available?
    Yes. The workstation includes a semiconductor-based low-temperature control system intended to help manage preparation conditions and reduce temperature-related evaporation effects.
    7. Can the Auto Prep 200 be used with photosensitive compounds?
    An optional light-shielding enclosure is available to help reduce light exposure during preparation. Users should verify whether the selected enclosure and operating conditions meet the needs of their specific compounds.
    8. Does the workstation support unattended operation?
    Yes. Once the preparation method and instrument settings are configured, the workstation can execute programmed procedures automatically. Appropriate laboratory safety measures and operating procedures should still be followed during unattended operation.
    9. Does the system generate preparation records?
    Yes. It monitors the preparation process and automatically generates preparation record reports after completion to support data storage and traceability. Specific audit-trail, electronic-signature, and regulatory-compliance capabilities should be confirmed with the manufacturer if required.


  • Frequently Asked Questions
    1. What is the Auto Prep 200 used for?
    The Auto Prep 200 automates laboratory liquid sample preparation, including mixed-standard preparation, calibration curve preparation, sample addition, dispensing, and dilution.
    2. Can the workstation prepare calibration curves automatically?
    Yes. Users can configure stock concentrations, target concentrations, and required volumes. The software calculates the necessary transfer volumes to support programmed calibration curve preparation.
    3. How does the Auto Prep 200 handle high dilution ratios?
    Its intelligent method software can identify dilution ratios that are too high for direct preparation and automatically create an intermediate solution for stepwise dilution.
    4. How does the workstation help prevent cross-contamination?
    It offers customizable multistage cleaning for the sampling needle and a disposable pipette-tip mode with automatic tip loading and disposal. These functions help reduce carryover, although appropriate method validation and cleaning procedures remain necessary.
    5. Can it prepare volatile solvent solutions?
    The dedicated piercing needle supports transfer from capped containers, helping reduce solvent exposure and evaporation during preparation. Suitability depends on solvent compatibility, container design, and the selected method.
    6. Is temperature control available?
    Yes. The workstation includes a semiconductor-based low-temperature control system intended to help manage preparation conditions and reduce temperature-related evaporation effects.
    7. Can the Auto Prep 200 be used with photosensitive compounds?
    An optional light-shielding enclosure is available to help reduce light exposure during preparation. Users should verify whether the selected enclosure and operating conditions meet the needs of their specific compounds.
    8. Does the workstation support unattended operation?
    Yes. Once the preparation method and instrument settings are configured, the workstation can execute programmed procedures automatically. Appropriate laboratory safety measures and operating procedures should still be followed during unattended operation.
    9. Does the system generate preparation records?
    Yes. It monitors the preparation process and automatically generates preparation record reports after completion to support data storage and traceability. Specific audit-trail, electronic-signature, and regulatory-compliance capabilities should be confirmed with the manufacturer if required.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com