    Aurora 6 Microwave Digestion System
    Introduction:
    The Aurora 6 microwave digestion instrument adopts full-tank temperature and pressure control technology, eliminating the need for consumables such as platinum resistors, safety membranes, gas conduits, and safety screws, offering both high cost-effectiveness and high safety. It features a microwave electromagnetic overload safety device, ensuring no damage to the instrument during microwave idle emission. The built-in standardized operation process guidance makes it easy for novice users to quickly grasp.
    Features:
    1. Patent digestion tank (patent number: 201410220143.3), capable of assembling 40 digestion tanks in less than 8 minutes, utilizing microwave uniformity technology to ensure the uniformity of the microwave field
    2. An efficient cooling system ensures that the temperature cools down to below 40℃ within 15 minutes after the reaction is completed
    3. The Twin Air bidirectional high-speed cooling system, coupled with optimized air duct design, can achieve rapid cooling within minutes
    4. Integrated control system, capable of setting multi-step ladder reaction programs, with the ability to store up to 600 methods that can be modified, and data retention for 12 months
    5. The combination of Zhen Shi infrared temperature measurement technology and patented overpressure self-sealing intelligent pressure control technology ensures greater reaction safety for each digestion tank and avoids the generation of consumables
    6. Integrated LCD screen
    Technical Specifications:
    Size (mm): 665 (mm) x 546 (mm) x 590 (mm)
    Microwave resonator: Industrial design-specific microwave resonator
    Pressure control method: automatic pressure relief through pressure shrapnel
    Complete machine installation power: 3200W
    Pressure digestion tank: The reaction tank can withstand pressures up to 140 bar and temperatures up to 330℃
    Calibration method: The system automatically guides the calibration process through built-in programs such as microwave power calibration and temperature sensor calibration.
    Microwave emission mode: Non-pulse continuous microwave output, with a control accuracy of ±1w
    Microwave control method: High-frequency closed-loop feedback (PID) control

     
     

     
  • Aurora 6 Microwave Digestion System
    Introduction:
    The Aurora 6 microwave digestion instrument adopts full-tank temperature and pressure control technology, eliminating the need for consumables such as platinum resistors, safety membranes, gas conduits, and safety screws, offering both high cost-effectiveness and high safety. It features a microwave electromagnetic overload safety device, ensuring no damage to the instrument during microwave idle emission. The built-in standardized operation process guidance makes it easy for novice users to quickly grasp.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com