  • Product Introduction
  • Other information
  • Model NumberATD-12R
    Brand NameBEIFENSANPU
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    ATD-12R Thermal Desorption System (Secondary Thermal Desorption Unit)
    Product Introduction
    ATD-12R Thermal Desorption System is an automated VOC and SVOC preconcentration instrument designed for integration with gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). It uses thermal desorption technology to extract volatile organic compounds from adsorption tubes, concentrate trace analytes into a small carrier gas volume, and achieve highly sensitive detection at ppb or lower concentration levels.
    By integrating sample preparation, thermal desorption, secondary desorption, cryogenic focusing, concentration, and GC/GC-MS injection into a fully automated workflow, the ATD-12R significantly improves laboratory efficiency while reducing manual operation requirements.
    The ATD-12R Secondary Thermal Desorption Unit is independently developed with advanced temperature control technology, extremely low background interference, excellent repeatability, and stable performance. It fully meets the analytical requirements of GB 50325-2020 Standard for Indoor Environmental Pollution Control of Civil Building Engineering, making it an ideal solution for indoor air quality monitoring, environmental analysis, and VOC testing applications.

     

    Performance Features
    • Fully automated operation
    One-button startup automatically completes adsorption tube desorption, secondary desorption, sample injection, and analysis processes without continuous operator supervision.
    • High sensitivity VOC detection
    Advanced thermal desorption and preconcentration technology significantly improves detection sensitivity for trace volatile and semi-volatile organic compounds.
    • Excellent temperature control performance
    The adsorption tube, injection valve, transfer line, focusing tube, and cooling module feature independent temperature control for accurate and stable analysis.
    • Low background and high repeatability
    Optimized heating system and high-temperature valve injection technology minimize sample residue and improve analytical accuracy.
    • Intelligent touch screen control
    Equipped with a user-friendly touch interface for parameter setting, real-time status monitoring, operation time display, and fault diagnosis.
    • Automatic leak detection and alarm system
    Provides automatic leak checking, flow monitoring, and fault alarm functions to ensure reliable operation.
    • Flexible analytical methods management
    Supports editing, storing, and recalling up to 10 analytical methods for different sample requirements.
    • High-performance cryogenic focusing technology
    Lower cooling temperature and rapid heating capability generate narrow chromatographic peaks and improve separation efficiency.
    • Integrated standard sample preparation function
    Built-in standard sample preparation capability simplifies calibration curve preparation and improves laboratory workflow.
    • Automatic focusing tube lifetime monitoring
    Real-time monitoring helps optimize maintenance schedules and ensures consistent analytical performance.

     

    Working Principle
    The ATD-12R thermal desorption system operates by collecting VOC and SVOC compounds onto adsorption tubes. During analysis, the adsorption tube is heated under controlled conditions, releasing trapped compounds into the carrier gas stream.
    The desorbed compounds are transferred into a cryogenic focusing tube where they are concentrated. After rapid heating, the concentrated sample is introduced into GC or GC-MS equipment for separation and identification.
    The secondary thermal desorption process enhances compound transfer efficiency, improves detection sensitivity, reduces sample loss, and enables accurate analysis of trace-level organic compounds.

     

    Technical Parameters
    Parameter Specification
    Adsorption Tube Temperature Range Room Temperature - 400℃
    Adsorption Tube Temperature Accuracy ±1℃
    Six-Port Valve Temperature Range Room Temperature - 220℃
    Six-Port Valve Temperature Accuracy ±1℃
    Sample Transfer Line Temperature Range Room Temperature - 220℃
    Transfer Line Temperature Accuracy ±1℃
    Focusing Tube Temperature Range -40℃ - 450℃
    Focusing Tube Heating Rate >4800℃/min
    Cold Trap Temperature Range -40℃ - Room Temperature
    Cooling Method Electronic cooling
    Cold Trap Temperature Accuracy ±1℃
    Sample Capacity 12 positions
    Back Flush Flow Rate 0-100 mL/min adjustable
    Sample Preparation Flow Rate 100 mL/min adjustable
    Desorption/Purge/Injection/Back Flush Time 0.0-999.9 min
    Adsorption Tube Specification Diameter 1/4 inch, Length 3.5 inch
    Power Consumption 900W
    Power Supply 220V, 50Hz
     

    Main Applications
    Indoor Air Quality Testing
    Used for detecting VOC pollutants in residential buildings, offices, schools, hospitals, and commercial facilities according to indoor environmental quality standards.
    Environmental Monitoring
    Suitable for trace organic compound analysis in atmospheric samples, workplace environments, and pollution monitoring projects.
    GC/GC-MS Sample Preparation
    Provides automated sample enrichment and injection solutions for laboratories performing VOC and SVOC analysis.
    Chemical and Industrial Analysis
    Applied in petrochemical, pharmaceutical, material science, and chemical industries for volatile organic compound testing.
    Research Laboratories
    Suitable for analytical chemistry research requiring high sensitivity VOC preconcentration technology.

     

    Advantages Compared with Traditional Direct Injection Methods
    Comparison Item ATD-12R Thermal Desorption System Traditional GC Injection
    Detection Sensitivity Excellent ppb-level detection capability Limited for trace compounds
    Sample Concentration Automatic enrichment and concentration No enrichment process
    Sample Preparation Fully automated Mostly manual operation
    Solvent Usage Solvent-free analysis Often requires solvents
    Environmental Impact Cleaner and safer operation More chemical waste
    Reproducibility High repeatability More affected by manual operation
    Sample Throughput 12-position automatic processing Lower efficiency
     

    Compliance and Standards
    The ATD-12R thermal desorption system is designed to satisfy the requirements of:
    • GB 50325-2020 Standard for Indoor Environmental Pollution Control of Civil Building Engineering
    It is suitable for professional laboratories performing indoor air pollution monitoring and VOC analysis.

     

    Frequently Asked Questions (FAQ)
    1. What is a thermal desorption system used for?
    A thermal desorption system is used to extract, concentrate, and transfer volatile and semi-volatile organic compounds from samples into GC or GC-MS instruments for highly sensitive analysis.
    2. What samples can be analyzed with the ATD-12R?
    The ATD-12R is mainly used for VOC and SVOC analysis in indoor air, environmental samples, industrial emissions, and other gas-phase samples collected with adsorption tubes.
    3. Can ATD-12R work with GC-MS instruments?
    Yes. The ATD-12R can synchronize with GC and GC-MS systems through automatic startup control or external event programs.
    4. How many samples can be processed at one time?
    The instrument supports 12 adsorption tube positions, allowing efficient batch sample analysis.
    5. What are the advantages of secondary thermal desorption technology?
    Secondary thermal desorption improves compound concentration efficiency, reduces interference, minimizes sample loss, and enhances detection sensitivity for trace-level compounds.
    6. Does the ATD-12R require constant operator supervision?
    No. The instrument supports fully automatic operation, including desorption, injection, monitoring, and fault alarms, reducing manual workload.
    7. Is ATD-12R suitable for indoor air quality testing laboratories?
    Yes. It is specifically designed to meet indoor environmental VOC testing requirements and is widely suitable for environmental monitoring laboratories, inspection institutions, and research centers.

     

    Product Summary
    ATD-12R Thermal Desorption System is a high-performance automated VOC preconcentration instrument for GC and GC-MS analysis. With advanced thermal desorption technology, precise temperature control, automated operation, and excellent analytical stability, it provides laboratories with an efficient solution for trace VOC and SVOC detection in indoor air, environmental monitoring, and industrial analysis applications.

     

     
  • Frequently Asked Questions (FAQ)
    1. What is a thermal desorption system used for?
    A thermal desorption system is used to extract, concentrate, and transfer volatile and semi-volatile organic compounds from samples into GC or GC-MS instruments for highly sensitive analysis.
    2. What samples can be analyzed with the ATD-12R?
    The ATD-12R is mainly used for VOC and SVOC analysis in indoor air, environmental samples, industrial emissions, and other gas-phase samples collected with adsorption tubes.
    3. Can ATD-12R work with GC-MS instruments?
    Yes. The ATD-12R can synchronize with GC and GC-MS systems through automatic startup control or external event programs.
    4. How many samples can be processed at one time?
    The instrument supports 12 adsorption tube positions, allowing efficient batch sample analysis.
    5. What are the advantages of secondary thermal desorption technology?
    Secondary thermal desorption improves compound concentration efficiency, reduces interference, minimizes sample loss, and enhances detection sensitivity for trace-level compounds.
    6. Does the ATD-12R require constant operator supervision?
    No. The instrument supports fully automatic operation, including desorption, injection, monitoring, and fault alarms, reducing manual workload.
    7. Is ATD-12R suitable for indoor air quality testing laboratories?
    Yes. It is specifically designed to meet indoor environmental VOC testing requirements and is widely suitable for environmental monitoring laboratories, inspection institutions, and research centers.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com