ALC10 aflatoxin tester

Product ID:HZNShqms006

Price: Please inquire PDF Format
Supply Ability:30SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberALC10
    Brand NameJINANHAINENG
    Payment TermsT/T, paypal
    ALC10 aflatoxin tester
    Introduction
    The ALC10 aflatoxin analyzer integrates a liquid chromatography system, a post-column photochemical derivative module, and a fixed optical path fluorescence detection module. The minimum detection concentration, linear range, repeatability and other indicators are in line with national standards and relevant regulations. 

    Features
    In the aflatoxin test, the ALC10 achieves the same level of general-purpose liquid chromatograph with a derivative and fluorescence detector, and can meet the testing needs at half the cost.
    The ALC10 has a built-in standard application method that uses a one-button operation, gentle overpressure for real-time monitoring and protection, and the whole machine is durable. Easily control the instrument without the need for the operator's expertise.
    The chromatographic workstation adopts a database storage mode and has a comprehensive audit trail function and privilege grading settings to fully guarantee workstation data security and compliance.
    The life of the light source is more than 20,000 hours, and the liquid leakage, over-temperature and over-pressure can be monitored and protected in real time, and the whole machine is durable. 
    Technical Parameters
    ALC10 machine performance parameters
    Retention time repeatability: RSD ≤ 0.2%
    Peak area repeatability: RSD ≤ 1.0%
    ALC10 infusion pump parameters
    Withstand voltage: 45MPa
    Flow rate range: 0.001mL/min-10.000mL/min
    Flow accuracy: ±0.5% (1mL/min)
    Flow precision: RSD ≤ 0.1% (1mL/min)
    ALC10 column oven parameters
    Temperature indication error: ±1 °C
    Temperature stability: ±0.1°C
    ALC10 detector parameters
    Excitation wavelength: 360nm
    Emission wavelength: 440nm
    Dynamic baseline drift: ≤ 500 counts/h
    Short-term baseline noise: ≤ 50 counts
    Minimum detection concentration: ≤ 0.03ng/mL (AFT B1, AFT G1)
    ≤ 0.01ng/mL (AFT B2, AFT G2)
    Linear range: > 103

  • Introduction
    The ALC10 aflatoxin analyzer integrates a liquid chromatography system, a post-column photochemical derivative module, and a fixed optical path fluorescence detection module. The minimum detection concentration, linear range, repeatability and other indicators are in line with national standards and relevant regulations. 
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com