Position: Home > > Analytical instruments > Electrochemical Equipment > Cassette moisture titrator > AKF-CH8 Multi-Position Automatic Karl Fischer Moisture Analyzer

AKF-CH8 Multi-Position Automatic Karl Fischer Moisture Analyzer

Product ID:FDks037

Price: Please inquire PDF Format
Supply Ability:50 SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberAKF-CH8
    Brand NameSHHEGONG
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    AKF-CH8 Multi-Position Automatic Karl Fischer Moisture Analyzer
    Product Introduction
    AKF-CH8 Multi-Position Automatic Karl Fischer Moisture Analyzer is a high-precision coulometric Karl Fischer moisture analyzer designed for rapid and reliable water content determination in various solid, liquid and powder samples. Based on the classic Karl Fischer coulometric titration principle, the instrument measures moisture content by generating iodine through electrolysis and accurately calculating the reaction between iodine and water in the sample.
    With an 8-position automatic sample turntable, intelligent endpoint detection, automatic analysis process and advanced data management functions, AKF-CH8 improves laboratory efficiency while ensuring excellent measurement accuracy and repeatability.
    The automatic Karl Fischer moisture analyzer is widely used for moisture analysis of freeze-dried powders, in vitro diagnostic reagents (IVD), battery cathode and anode materials, separators, plastic pellets, lubricating oils, adhesives, chemicals and other moisture-sensitive materials.

     

    Performance Features
    • Multi-position automatic analysis system
    Equipped with an 8-position automatic sample carousel, enabling continuous unattended sample testing and improving laboratory throughput.
    • High-precision coulometric Karl Fischer titration technology
    Based on the internationally recognized Karl Fischer principle, providing accurate trace moisture measurement from microgram levels.
    • Automatic constant current polarization detection
    The system automatically adjusts electrolysis current from 10 mA to 400 mA without manual endpoint judgment, ensuring stable and reliable results.
    • Wide sample compatibility
    Built-in 6 electrolysis modes support different Karl Fischer reagents and adapt to various sample types.
    • Intelligent touchscreen operation
    Featuring a color touchscreen and digital keyboard interface, providing simple operation and intuitive workflow.
    • Automatic calculation and data management
    Test results are automatically calculated, stored and searchable. Data can be backed up, exported and printed.
    • Flexible analysis parameter settings
    Supports customized settings including titration delay, endpoint delay, drift compensation, blank correction and fixed test duration.
    • Real-time E-T curve display
    Displays titration electrolysis curves during analysis, allowing users to monitor the measurement process visually.
    • Long-term stability and low maintenance
    One-button operation, automatic analysis and intelligent control reduce operating errors and improve instrument service life.

     

    Working Principle
    The AKF-CH8 Automatic Karl Fischer Moisture Analyzer uses the coulometric Karl Fischer titration method to determine water content.
    During measurement, iodine is generated electrolytically inside the reaction cell. The generated iodine reacts quantitatively with water contained in the sample according to the Karl Fischer reaction formula. Since the amount of iodine generated is directly proportional to the amount of water present, the instrument calculates the moisture content based on the consumed electrical charge.
    The automatic detection system monitors the endpoint through polarization changes and stops electrolysis automatically when all water has reacted, providing accurate and repeatable moisture measurement results.

     

    Technical Parameters
    Parameter Specification
    Measurement Method Coulometric Karl Fischer titration
    Model AKF-CH8
    Power Supply AC 220V / 50Hz
    Sample Positions 8 positions automatic turntable
    Standard Sample Bottle 10 mL
    Stirring Speed 0–15 levels adjustable
    Stirring Speed Range 0–800 rpm
    Electrolysis Speed <2.2 mg/min
    Measurement Range 3 μg–199 mg H₂O
    Detection Resolution 0.1 μg H₂O
    Moisture Mass Display Resolution 0.01 μg
    Accuracy ±3 μg (<10–1000 μg H₂O); ≤0.3% (>1000 μg H₂O)
    Electrolysis Current Automatic adjustment 10–400 mA
    Electrolysis Modes 6 selectable modes
    Heating Furnace Temperature Range 40℃–280℃
    Temperature Resolution 0.1℃
    Temperature Accuracy ±5℃ (160℃ condition)
    Heating Rate 18℃/min (below 160℃)
    Carrier Gas Heating Tube Available
    Carrier Gas Pressure 0.1–0.4 MPa
    Carrier Gas Flow Range 0–100 mL/min
    Flow Resolution 0.1 mL/min
    Communication Interface RS232 printer interface, USB interface
    Weight 13 kg
    Dimensions 456 × 258 × 364 mm
    Operating Environment Temperature 5–40℃, humidity <65%
     

    Software Functions
    • Three-level user account management with different permission settings
    • Analysis methods can be edited, stored and recalled
    • Automatic sample injection, automatic analysis and automatic endpoint judgment
    • Automatic result calculation and storage
    • Test data query, backup, export and printing functions
    • Multiple calculation formulas available for different applications
    • Calibration function for different moisture ranges

     

    Application Scenarios
    Battery Material Moisture Analysis
    AKF-CH8 is suitable for moisture detection of lithium battery materials, including:
    • Cathode materials
    • Anode materials
    • Battery separators
    • Battery-related chemical materials
    Low moisture measurement capability helps improve battery performance, safety and production consistency.

     
    Pharmaceutical and IVD Industry
    The instrument is widely used for moisture determination of:
    • Freeze-dried pharmaceutical powders
    • In vitro diagnostic reagents
    • Pharmaceutical raw materials
    • Biological products
    Accurate moisture control helps ensure product stability and storage performance.

     
    Chemical and Material Testing
    Suitable for moisture analysis of:
    • Plastic pellets
    • Adhesives
    • Organic chemicals
    • Lubricants
    • Industrial raw materials

     

    AKF-CH8 vs Traditional Manual Karl Fischer Moisture Testing
    Comparison Item AKF-CH8 Automatic Karl Fischer Analyzer Traditional Manual Moisture Testing
    Operation Method Automatic analysis Manual operation required
    Sample Processing 8-position automatic testing Single sample testing
    Endpoint Detection Automatic Manual judgment
    Measurement Accuracy High precision micro-water detection Easily affected by operator experience
    Data Management Automatic storage/export/printing Manual recording
    Efficiency Suitable for batch testing Low throughput
    Application Range Pharmaceutical, battery, chemical, materials General laboratory applications
     

    Frequently Asked Questions (FAQ)
    1. What is AKF-CH8 Karl Fischer Moisture Analyzer used for?
    AKF-CH8 is used for precise water content measurement in various materials, including freeze-dried powders, IVD reagents, battery materials, plastics, lubricants and adhesives.
    2. What is the measurement principle of AKF-CH8?
    The instrument uses coulometric Karl Fischer titration technology. Water reacts with electrolytically generated iodine, and the instrument calculates moisture content according to the consumed electrical charge.
    3. What samples can be tested by AKF-CH8?
    It can analyze solid, liquid and powder samples, especially moisture-sensitive materials such as battery components, pharmaceutical products, chemicals and industrial materials.
    4. What are the advantages of the 8-position automatic turntable?
    The 8-position design enables automatic sequential testing of multiple samples, reducing manual operation and improving laboratory efficiency.
    5. Is manual endpoint judgment required?
    No. The instrument automatically detects the endpoint through polarization analysis and stops the titration process automatically.
    6. Can the test parameters be customized?
    Yes. Users can configure titration delay, endpoint delay, drift correction, blank correction and fixed-time measurement settings according to different sample requirements.
    7. Why choose an automatic Karl Fischer moisture analyzer instead of a traditional moisture tester?
    Automatic Karl Fischer analyzers provide higher accuracy, faster testing speed and better repeatability, especially for trace moisture detection where precise water content control is required.
    8. Is AKF-CH8 suitable for battery material manufacturers?
    Yes. AKF-CH8 is widely suitable for lithium battery-related materials such as cathode materials, anode materials and separators where strict moisture control is required.

     

    Product Summary
    AKF-CH8 Multi-Position Automatic Karl Fischer Moisture Analyzer combines high-precision coulometric moisture detection, automatic 8-position operation, intelligent software control and advanced data management. It is an ideal moisture analysis solution for pharmaceutical, battery, chemical, material research and quality control laboratories requiring accurate and efficient water content measurement.

     
     
  • Frequently Asked Questions (FAQ)
    1. What is AKF-CH8 Karl Fischer Moisture Analyzer used for?
    AKF-CH8 is used for precise water content measurement in various materials, including freeze-dried powders, IVD reagents, battery materials, plastics, lubricants and adhesives.
    2. What is the measurement principle of AKF-CH8?
    The instrument uses coulometric Karl Fischer titration technology. Water reacts with electrolytically generated iodine, and the instrument calculates moisture content according to the consumed electrical charge.
    3. What samples can be tested by AKF-CH8?
    It can analyze solid, liquid and powder samples, especially moisture-sensitive materials such as battery components, pharmaceutical products, chemicals and industrial materials.
    4. What are the advantages of the 8-position automatic turntable?
    The 8-position design enables automatic sequential testing of multiple samples, reducing manual operation and improving laboratory efficiency.
    5. Is manual endpoint judgment required?
    No. The instrument automatically detects the endpoint through polarization analysis and stops the titration process automatically.
    6. Can the test parameters be customized?
    Yes. Users can configure titration delay, endpoint delay, drift correction, blank correction and fixed-time measurement settings according to different sample requirements.
    7. Why choose an automatic Karl Fischer moisture analyzer instead of a traditional moisture tester?
    Automatic Karl Fischer analyzers provide higher accuracy, faster testing speed and better repeatability, especially for trace moisture detection where precise water content control is required.
    8. Is AKF-CH8 suitable for battery material manufacturers?
    Yes. AKF-CH8 is widely suitable for lithium battery-related materials such as cathode materials, anode materials and separators where strict moisture control is required.

     
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com