    Product Overview
    The AHS-50 Automatic Headspace Sampler is an automated sample introduction system designed for gas chromatography (GC) analysis of volatile compounds. It uses the headspace sampling technique to separate volatile components from liquid, solid, or mixed samples before introducing the gas-phase sample into a gas chromatograph.
    The sample is sealed in a headspace vial and heated to promote the volatilization of volatile components. After equilibrium is established between the gas and liquid or solid phases, the sampler automatically extracts the headspace gas and introduces it into the GC system for qualitative and quantitative analysis.
    The AHS-50 features a rotary-valve multi-dimensional gas-path injection system, simplified gas-path design, inert-treated sample-contact components, optional EPC electronic pressure control, four preheating stations, and storage for up to 10 analytical methods.

    Key Features
    • Rotary-valve multi-dimensional gas-path injection system designed for reliable high-temperature operation
    • Simplified gas-path design reduces potential leakage points and improves operating reliability
    • Sample-contact gas paths and sample valves use inert surface treatment to minimize sample interaction
    • Optional EPC electronic pressure control with digital pressure display
    • Automatic gas-path leak detection and alarm functions when equipped with EPC
    • Injection volume can be controlled by adjusting injection time
    • Up to 10 analytical methods can be stored for different analytical standards
    • Full-color touchscreen display with an intuitive user interface
    • Real-time display of operating procedures, set parameters, and actual values
    • Four preheating stations support cyclic heating and improve sample processing efficiency
    • Supports liquid, solid, and mixed samples
    • 50 headspace vial positions for automated sample processing
    • Standard 20 mL headspace vials
    • Suitable for integration with gas chromatographs for automated volatile compound analysis
    • Headspace sampler, functional modules, components, and accessories can be configured according to application requirements

    Working Principle
    The AHS-50 uses the headspace sampling principle. A sample is placed in a sealed headspace vial and heated to a preset temperature. Volatile components in the sample evaporate from the sample matrix and distribute between the sample phase and the gas phase until equilibrium is established.
    The sampler then extracts a defined amount of gas from the headspace and introduces it into the gas chromatograph. The GC separates and detects the volatile components, allowing their composition and concentration to be determined.
    The AHS-50 controls sample heating, gas-path switching, injection timing, and other operating parameters automatically, reducing manual intervention and improving measurement consistency.

    System Configuration
    The AHS-50 mainly integrates:
    • Headspace sample heating system
    • Rotary-valve injection system
    • Multi-dimensional gas-path system
    • Temperature control system
    • Optional EPC electronic pressure control system
    • Sample valve and inert-treated sample-contact components
    • Gas-path leak detection and alarm system
    • Touchscreen control interface
    • Four preheating stations
    • 50-position headspace vial tray

    Technical Specifications
    Parameter Specification
    Model AHS-50
    Sample Temperature Control Range Ambient temperature to 380°C
    Sample Temperature Accuracy ±0.5°C
    Sample Temperature Setting Resolution 1°C
    Transfer Line Temperature Range Ambient temperature to 260°C
    Transfer Line Temperature Accuracy ±0.5°C
    Transfer Line Setting Resolution 1°C
    Valve Temperature Range Ambient temperature to 260°C
    Valve Temperature Accuracy ±1°C
    Valve Temperature Setting Resolution 1°C
    Number of External Events 15
    External Event Time Range 0.1–99 min
    Timer Error <0.1%
    Cylinder Drive Gas Pressure <0.4 MPa, adjustable
    Gas Path Pressure Resistance >0.4 MPa
    Preheating Stations 4
    Headspace Vial Positions 50
    Standard Headspace Vial Size 20 mL
    Analytical Repeatability RSD <1%*
    Power Consumption <1000 VA
    Linkage Signal Switching Time <2 s
    Dimensions (H × W × L) 580 × 564 × 666 mm
    Weight Approx. 40 kg
    *Repeatability is also related to the performance of the connected GC system and operating technique.

    Applications
    The AHS-50 is suitable for volatile and semi-volatile organic compound analysis in a wide range of samples, including:
    • Drinking water and wastewater
    • Food and beverage samples
    • Pharmaceutical products
    • Blood and biological samples
    • Soil and sediment
    • Sludge and mud samples
    • Cosmetics and soaps
    • Packaging materials
    • Metal foils and paper materials
    • Fragrances and flavoring materials
    • Petrochemical products
    • Polymer and coating materials

    Application Fields
    Petrochemical Industry
    Used for determination of volatile organic compounds in polymer monomers, coatings, and other petrochemical materials.
    Environmental Analysis
    Suitable for analysis of volatile halogenated hydrocarbons in drinking water and toxic volatile organic compounds in industrial wastewater.
    Food and Beverage Testing
    Used for quality control of alcoholic beverages, vinegar, soy sauce, and other food products, as well as analysis of acetaldehyde residues in packaging materials and solvent residues in extracted oils.
    Pharmaceutical Testing
    Used for residual organic solvent analysis in pharmaceutical products.
    Medical and Hygiene Applications
    Suitable for analysis of residual fumigants and sterilization-related volatile compounds in medical products.
    Fragrance and Flavor Analysis
    Can be used to analyze volatile aroma compounds in beer, tea, fragrances, and flavoring materials.
    Forensic Chemistry
    Suitable for determination of ethanol, ketones, aldehydes, and other volatile compounds in biological samples such as blood and urine.
    Soil and Environmental Samples
    Can be used for the determination of volatile organic compounds in soil, sediment, sludge, and related environmental samples.

    Advantages Over Manual Headspace Sampling
    Feature AHS-50 Automatic Headspace Sampler Manual Headspace Sampling
    Sample Processing Automated Manual
    Vial Capacity 50 positions Depends on operator
    Preheating 4 stations Usually manual or limited
    Temperature Control Programmable More operator-dependent
    Injection Timing Automatically controlled Manual
    Method Storage Up to 10 methods Manual parameter setting
    Operation Touchscreen automated control More manual intervention
    Repeatability RSD <1%* More dependent on operator
    GC Integration Designed for automated GC analysis Usually requires manual operation

    FAQ
    What is the AHS-50 used for?
    The AHS-50 is an automatic headspace sampler used to prepare and inject gas-phase samples into a gas chromatograph for analysis of volatile compounds.
    What types of samples can be analyzed?
    It supports liquid, solid, and mixed samples, including water, food, pharmaceuticals, soil, sludge, cosmetics, packaging materials, and petrochemical products.
    How many headspace vials can the AHS-50 accommodate?
    The system provides 50 headspace vial positions and uses standard 20 mL headspace vials.
    What is the maximum sample heating temperature?
    The sample temperature control range is from ambient temperature to 380°C.
    How many preheating stations are available?
    The AHS-50 has four preheating stations that can operate cyclically to improve sample processing efficiency.
    Does the AHS-50 support electronic pressure control?
    Yes. EPC electronic pressure control is available as an option. With EPC, digital pressure display, automatic gas-path leak detection, and alarm functions can be provided.
    How many analytical methods can be stored?
    The system can store up to 10 methods for different analytical standards and applications.
    Can the AHS-50 be connected to a gas chromatograph?
    Yes. It is designed as an automatic headspace sample introduction system for GC analysis and provides linkage signal output for system integration.
    Product Summary
    The AHS-50 Automatic Headspace Sampler is a reliable automated headspace injection system for gas chromatography analysis of volatile compounds. With 50 vial positions, four preheating stations, precise temperature control up to 380°C, programmable injection timing, touchscreen operation, and optional EPC, it is suitable for environmental, food, pharmaceutical, petrochemical, forensic, and material testing applications.
     


  • FAQ
    What is the AHS-50 used for?
    The AHS-50 is an automatic headspace sampler used to prepare and inject gas-phase samples into a gas chromatograph for analysis of volatile compounds.
    What types of samples can be analyzed?
    It supports liquid, solid, and mixed samples, including water, food, pharmaceuticals, soil, sludge, cosmetics, packaging materials, and petrochemical products.
    How many headspace vials can the AHS-50 accommodate?
    The system provides 50 headspace vial positions and uses standard 20 mL headspace vials.
    What is the maximum sample heating temperature?
    The sample temperature control range is from ambient temperature to 380°C.
    How many preheating stations are available?
    The AHS-50 has four preheating stations that can operate cyclically to improve sample processing efficiency.
    Does the AHS-50 support electronic pressure control?
    Yes. EPC electronic pressure control is available as an option. With EPC, digital pressure display, automatic gas-path leak detection, and alarm functions can be provided.
    How many analytical methods can be stored?
    The system can store up to 10 methods for different analytical standards and applications.
    Can the AHS-50 be connected to a gas chromatograph?
    Yes. It is designed as an automatic headspace sample introduction system for GC analysis and provides linkage signal output for system integration.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com