Position: Home > > Lab general equipment > Heating / drying equipment > Water/oil bath > AC900B Laboratory Water Chiller – 900W Recirculating Cooling System

AC900B Laboratory Water Chiller – 900W Recirculating Cooling System

Product ID:SYJRGZshyyy039

Price: Please inquire PDF Format
Supply Ability:50SETS/MON
Port:SHENZHEN
  • Product Introduction
  • Other information
  • Model NumberAC900B
    Brand NameBJHAOTIANHUI
    Payment TermsTT,PAYPAL,Alibaba.com Pay
    AC900B Laboratory Water Chiller – 900W Recirculating Cooling System

    Product Overview
    The AC900B Laboratory Water Chiller is designed to provide continuous circulating cooling for laboratory instruments and analytical equipment. It is suitable for atomic absorption spectrophotometers, inductively coupled plasma (ICP) emission spectrometers, scanning electron microscopes (SEM), high-frequency fusion machines, magnetron sputtering systems, plasma etching equipment, direct-reading spectrometers, X-ray diffraction (XRD) instruments, and other equipment requiring stable cooling water.
    With a nominal cooling capacity of 900W, an 8L water tank, and an adjustable output temperature range of 5–35°C, the AC900B provides reliable heat removal and stable operating conditions for laboratory applications.

    Key Features
    • Precise Temperature Control: Intelligent start-stop temperature control adjustment helps maintain stable cooling temperatures with ±1°C accuracy.
    • Efficient Heat Dissipation: Optimized structural design and effective ventilation improve heat dissipation performance.
    • Enhanced Thermal Insulation: A well-insulated cooling system helps reduce heat exchange and maintain cooling efficiency.
    • Easy Cleaning: The stainless steel open-top water bath allows convenient cleaning and maintenance.
    • Optional Alarm Outputs: Optional water level, water flow, and high/low temperature alarm signal outputs support equipment monitoring.
    • Stainless Steel Water Circuit: Stainless steel pipes and pump components help minimize water contamination.
    • Optional Water Filtration: An optional filtration system supports 10 μm particle filtration and ion purification resin treatment.
    • Low-Noise Operation: Effective vibration reduction helps minimize operating noise.

    Working Principle
    The AC900B operates through a closed-loop water circulation system. The cooling unit removes heat from the circulating water, while the integrated pump delivers cooled water to the connected laboratory instrument.
    After absorbing heat from the equipment, the warmed water returns to the chiller for recooling and recirculation. The intelligent start-stop temperature control system regulates cooling operation to maintain the preset water temperature within the specified control accuracy.
    This continuous circulation process helps prevent overheating and supports stable operation of laboratory instruments.

    Technical Specifications
    Parameter Specification
    Model AC900B
    Nominal Cooling Capacity 900 W (at 25°C)
    Output Temperature Range 5–35°C
    Temperature Control Accuracy ±1°C
    Water Tank Capacity 8 L
    Output Pressure 0.05–0.1 MPa
    Output Flow Rate 8–15 L/min
    Filter Rating 10 μm
    Alarm Signals Water level alarm, high/low temperature alarm
    Dimensions (W × D × H) 360 × 450 × 660 mm

    Applications
    The AC900B laboratory water chiller is suitable for cooling a wide range of laboratory and industrial instruments, including:
    • Atomic Absorption Spectrophotometers (AAS)
    • ICP Emission Spectrometers
    • Scanning Electron Microscopes (SEM)
    • High-Frequency Fusion Machines
    • Magnetron Sputtering Systems
    • Plasma Etching Equipment
    • Direct-Reading Spectrometers
    • X-Ray Diffraction (XRD) Instruments
    • Other laboratory equipment requiring circulating water cooling

    Applicable Standards
    The AC900B is designed for laboratory equipment cooling applications. No specific compliance standards or certifications are provided in the available product specifications. Users should confirm any required regulatory or equipment-specific requirements before purchase.

    Product Comparison
    The following table compares the AC900B with general-purpose laboratory water chillers in the same application category. Values for general-purpose models are indicative rather than specifications of a particular product.
    Parameter AC900B General-Purpose Laboratory Chiller
    Cooling Capacity 900 W Varies by model
    Temperature Range 5–35°C Model-dependent
    Temperature Accuracy ±1°C Model-dependent
    Water Tank Capacity 8 L Varies
    Water Flow Rate 8–15 L/min Varies
    Output Pressure 0.05–0.1 MPa Varies
    Water Circuit Material Stainless Steel Model-dependent
    Filtration Optional 10 μm filtration Optional or unavailable
    The AC900B combines a 900W cooling capacity, stainless steel water circulation components, and optional filtration in a compact laboratory cooling system. It is a practical option for instruments requiring stable circulating cooling water.

    Frequently Asked Questions (FAQ)
    Q1: What is the AC900B laboratory water chiller used for?
    The AC900B is used to provide circulating cooling water for laboratory instruments such as atomic absorption spectrophotometers, ICP spectrometers, scanning electron microscopes, XRD systems, and other heat-generating equipment.
    Q2: What is the cooling capacity of the AC900B?
    The AC900B has a nominal cooling capacity of 900W at an ambient temperature of 25°C.
    Q3: What is the operating temperature range?
    The output water temperature can be set within a range of 5–35°C, with a temperature control accuracy of ±1°C.
    Q4: What is the water circulation flow rate?
    The specified output flow rate is 8–15 L/min, with an output pressure of 0.05–0.1 MPa.
    Q5: Does the AC900B have a water filtration system?
    An optional filtration system is available. It can provide 10 μm particle filtration and ion purification resin treatment to help improve circulating water quality.
    Q6: What alarm functions are available?
    The system supports water level alarms and high/low temperature alarms. Water flow alarm signal output is also available as an option.
    Q7: How much water does the AC900B water tank hold?
    The integrated water tank has a capacity of 8 liters.
    Q8: What should be considered when selecting a laboratory water chiller?
    Users should consider the cooling load, required water temperature, circulation flow rate, output pressure, water quality requirements, and compatibility with the connected instrument. The AC900B is suitable when these requirements fall within its specified operating parameters.
     


  • Frequently Asked Questions (FAQ)
    Q1: What is the AC900B laboratory water chiller used for?
    The AC900B is used to provide circulating cooling water for laboratory instruments such as atomic absorption spectrophotometers, ICP spectrometers, scanning electron microscopes, XRD systems, and other heat-generating equipment.
    Q2: What is the cooling capacity of the AC900B?
    The AC900B has a nominal cooling capacity of 900W at an ambient temperature of 25°C.
    Q3: What is the operating temperature range?
    The output water temperature can be set within a range of 5–35°C, with a temperature control accuracy of ±1°C.
    Q4: What is the water circulation flow rate?
    The specified output flow rate is 8–15 L/min, with an output pressure of 0.05–0.1 MPa.
    Q5: Does the AC900B have a water filtration system?
    An optional filtration system is available. It can provide 10 μm particle filtration and ion purification resin treatment to help improve circulating water quality.
    Q6: What alarm functions are available?
    The system supports water level alarms and high/low temperature alarms. Water flow alarm signal output is also available as an option.
    Q7: How much water does the AC900B water tank hold?
    The integrated water tank has a capacity of 8 liters.
    Q8: What should be considered when selecting a laboratory water chiller?
    Users should consider the cooling load, required water temperature, circulation flow rate, output pressure, water quality requirements, and compatibility with the connected instrument. The AC900B is suitable when these requirements fall within its specified operating parameters.
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
+86-18620722006
instruments@instrumentstrade.com