Position: Home > > Analytical instruments > Spectrometry > Atomic absorption spectroscopy > AAS9000 flame graphite furnace integrated atomic absorption spectrophotometer

AAS9000 flame graphite furnace integrated atomic absorption spectrophotometer

Product ID:FGyzxs014

Price: Please inquire PDF Format
Supply Ability:20SETS/MON
Port:SHENZHEN
share:
  • Product Introduction
  • Consulting
  • Model NumberAAS9000
    Brand NameYIMA
    Payment TermsT/T, paypal
    Features:
    Host
    1, total reflection achromatic optical system.
    The use of tire mirror instead of convex lens as the instrument of optical focusing equipment, effectively solve the different elements of different color differences in the problem, improve the efficiency of the optical system.
    2, C-T monochromator.
    Using 1800 lines / mm, shine wavelength 230nm grating spectroscopy system.
    3, eight elements lighthouse.
    Eight lights are equipped with eight independent lights power, a lamp work, up to seven lights preheat, saving the lamp and warm-up time, so that element measurement faster and more convenient.
    4, fully automated design.
    In addition to the host power switch, the instrument all functions through computer monitoring and control.
    5, USB2.0 communication.
    The industry's first to use USB2.0 communication interface to enhance the communication speed, compatible with the latest computer systems.
    6, background correction system.
    With deuterium lamp and self-absorption of two background correction mode, the background signal 1A, deductive background ability of more than 30 times.
    7, the appearance of the use of streamlined sheet metal process design, simple fashion, beautiful and generous
    8, independent intellectual property rights, functional, powerful analysis software.
    User-friendly interface, so that your operation easy, you can switch between Chinese and English Windows-style software interface, Windows XP Windows 7 and other operating systems under the perfect operation, automatic qualitative, quantitative analysis, automatic calculation of element content, automatic test report The
    Flame system
    1, pure titanium atomization chamber, pure titanium burner.
    Effectively prevent acid gas corrosion, longer service life.
    2, efficient glass atomizer.
    The use of special efficient glass atomizer, atomization efficiency, easy maintenance and replacement.
    3, mass flow controller to achieve acetylene flow control.
    Mass flow controller precise control of acetylene flow, accuracy of 1ml / min, and dynamic monitoring of the flow, easy to use, safe and reliable.
    4, more security measures to make the sample analysis more secure and reliable.
    1) acetylene leak protection
    2) acetylene pressure monitoring
    3) air pressure monitoring
    4) Burner status monitoring
    5) flame status monitoring
    6) Water seal status monitoring
    Graphite furnace system
    1, graphite furnace power supply built-in.
    Graphite furnace power supply, atomic absorption host is located in the same instrument, the instrument space is more compact, shorten the cable length, reducing the graphite furnace power to the outside of the electromagnetic interference, improve the graphite tube heating efficiency.
    2, graphite furnace temperature control accuracy, heating speed.
    Using high-power transformers, micro-resistance cable and light control temperature, and with the software, hardware temperature correction system, high temperature temperature control accuracy of up to ± 1%.
    3, more security measures to make the sample analysis more secure and reliable.
    1) cooling water flow monitoring
    2) Carrier pressure monitoring
    3) Graphite tube temperature monitoring
    4) Graphite furnace temperature monitoring
    4, automatic carrier gas flow control.
    Graphite furnace gas, outside the gas all by the computer according to the software temperature control process automatically.
    Autosampler
    150-bit turntable flame graphite furnace general autosampler.
    Polar coordinate turntable autosampler, high positioning accuracy, stable and reliable operation, easy maintenance and use. (AAS8000-M and AAS9000-M products are manual injection mode, not equipped with autosampler)
    Technical indicators
    Host
    Monochromator Type: Czerny-Turner
    Wavelength range: 190nm ~ 900nm
    Wavelength Accuracy: ± 0.25nm
    Wavelength repeatability: <0.05nm
    Spectral bandwidth: 0.1 / 0.2 / 0.4 / 0.7 / 1.4 nm Five-speed automatic switching
    Flame system
    Flame method for copper (Cu) Precision: <0.8%
    Fire detection copper (Cu) detection limit: <0.006ug / mL
    (Cu) Characteristic concentration: <0.025μg / ml / 1%
    Static stability: 0.003 Abs (static)
    Dynamic stability: 0.005 Abs (dynamic)
    Graphite furnace system
    Graphite furnace temperature range: room temperature - 3000
    Graphite furnace heating rate: 3000 / s
    Graphite furnace measured cadmium (Cd) Precision: 2% (automatic injection mode)
    Graphite furnace measured cadmium (Cd) Precision: 5% (manual injection mode)
    Calcium (Cd) detection limit of graphite furnace: 1.0pg

  • Features:
    Host
    1, total reflection achromatic optical system.
    The use of tire mirror instead of convex lens as the instrument of optical focusing equipment, effectively solve the different elements of different color differences in the problem, improve the efficiency of the optical system.
    2, C-T monochromator.
    Using 1800 lines / mm, shine wavelength 230nm grating spectroscopy system.
    3, eight elements lighthouse.
    Eight lights are equipped with eight independent lights power, a lamp work, up to seven lights preheat, saving the lamp and warm-up time, so that element measurement faster and more convenient.
    4, fully automated design.
    In addition to the host power switch, the instrument all functions through computer monitoring and control.
    5, USB2.0 communication.
    The industry's first to use USB2.0 communication interface to enhance the communication speed, compatible with the latest computer systems.
    6, background correction system.
    With deuterium lamp and self-absorption of two background correction mode, the background signal 1A, deductive background ability of more than 30 times.
    7, the appearance of the use of streamlined sheet metal process design, simple fashion, beautiful and generous
    8, independent intellectual property rights, functional, powerful analysis software.
    User-friendly interface, so that your operation easy, you can switch between Chinese and English Windows-style software interface, Windows XP Windows 7 and other operating systems under the perfect operation, automatic qualitative, quantitative analysis, automatic calculation of element content, automatic test report The
    Flame system
    1, pure titanium atomization chamber, pure titanium burner.
    Effectively prevent acid gas corrosion, longer service life.
    2, efficient glass atomizer.
    The use of special efficient glass atomizer, atomization efficiency, easy maintenance and replacement.
    3, mass flow controller to achieve acetylene flow control.
    Mass flow controller precise control of acetylene flow, accuracy of 1ml / min, and dynamic monitoring of the flow, easy to use, safe and reliable.
    4, more security measures to make the sample analysis more secure and reliable.
    1) acetylene leak protection
    2) acetylene pressure monitoring
    3) air pressure monitoring
    4) Burner status monitoring
    5) flame status monitoring
    6) Water seal status monitoring
    Graphite furnace system
    1, graphite furnace power supply built-in.
    Graphite furnace power supply, atomic absorption host is located in the same instrument, the instrument space is more compact, shorten the cable length, reducing the graphite furnace power to the outside of the electromagnetic interference, improve the graphite tube heating efficiency.
    2, graphite furnace temperature control accuracy, heating speed.
    Using high-power transformers, micro-resistance cable and light control temperature, and with the software, hardware temperature correction system, high temperature temperature control accuracy of up to ± 1%.
    3, more security measures to make the sample analysis more secure and reliable.
    1) cooling water flow monitoring
    2) Carrier pressure monitoring
    3) Graphite tube temperature monitoring
    4) Graphite furnace temperature monitoring
    4, automatic carrier gas flow control.
    Graphite furnace gas, outside the gas all by the computer according to the software temperature control process automatically.
    Autosampler
    150-bit turntable flame graphite furnace general autosampler.
    Polar coordinate turntable autosampler, high positioning accuracy, stable and reliable operation, easy maintenance and use. (AAS8000-M and AAS9000-M products are manual injection mode, not equipped with autosampler)
Products
Analytical instruments
Physical property test
Environmental monitoring and analysis
Lab general equipment
About us
About this website
Our service
Product purchase
Contact Us

Newsletter

Make Sure you dont miss interesting happenings by joining our newsletter program.

Contact Us
18620722006
instruments@instrumentstrade.com